Reference Guide

Detailed
Description
Link tuning table not supported for this IO modular.
Recommended
Response Action
Update the CMC firmware. If the problem persists, contact support.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
HWC5035
Message An over-temperature event detected on I/O module
arg1
.
Arguments
arg1 =
number
Detailed
Description
The I/O module over heated.
Recommended
Response Action
Do the following: 1) Make sure fans are installed and working correctly. 2) Check the
temperature sensor status for the chassis and make sure it is within the chassis operating
temperature range. 3) Reseat the I/O module to clear the over-temperature condition. If the
problem persists, contact the service provider.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
HWC5036
Message A failure is detected on IO module
arg1
.
406