Reference Guide

FAN0022
Message The
arg1
sensor has failed, and the last recorded value by the sensor was
arg2
RPM.
Arguments
arg1 =
sensor name
arg2 =
fan speed
Detailed
Description
The sensor identified in the message has failed. The sensor may be required for optimal system
performance.
Recommended
Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults. If the fan
sensor has failed, replace the system board. For more information, contact your service
provider.
Category System Health
SubCategory FAN = Fan Event
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
FAN0023
Message Unable to read the
arg1
sensor value.
Arguments
arg1 =
sensor name
Detailed
Description
The fan sensor identified in the message has failed or the fan has failed.
Recommended
Response Action
Do the following: 1) Remove the old fan, install a new fan and power cycle the system to check
if the fan is working properly, 2) Replace the system board if the fan sensor has failed. 3) If the
issue persists, contact your service provider.
Category System Health
SubCategory FAN = Fan Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
354