Reference Guide
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
ENC5
Message Redundancy on
arg1
is degraded
Arguments
•
arg1 =
Enclosure Name
Detailed
Description
One or more of the enclosure components has failed. For example, a fan or power supply may
have failed. Although the enclosure is currently operational, the failure of additional
components could cause the enclosure to fail.
Recommended
Response Action
Identify and replace the failed component. To identify the failed component, select the
enclosure in the tree view and click the Health subtab. Any failed component will be identified
with a red X on the enclosures Health subtab. Alternatively, you can select the Storage object
and click the Health subtab. The controller status displayed on the Health subtab indicates
whether a controller has a failed or degraded component. See the enclosure documentation
for information on replacing enclosure components and for other diagnostic information.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
ENC6
Message Communication timeout on
arg1
.
Arguments
•
arg1 =
Enclosure Name
Detailed
Description
The controller is unable to communicate with an enclosure. There are several reasons for
communication loss. For example, there may be a bad or loose cable. An unusual amount of I/O
may also interrupt communication with the enclosure. In addition, communication loss may be
caused by software, hardware, or firmware problems, bad or failed power supplies, and
enclosure shutdown.
340