Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
ENC4
Message
arg1
firmware mismatch.
Arguments
arg1 =
Enclosure Name
Detailed
Description
The firmware on the EMM modules is not the same version. It is required that both modules
have the same version of the firmware. This alert may be caused when you attempt to insert an
EMM module that has a different firmware version than an existing module.
Recommended
Response Action
Download the same version of the firmware to both EMM modules.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
ENC40
Message A new enclosure was detected on
arg1
.
Arguments
arg1 =
controller name
Detailed
Description
The controller detected a new enclosure. This is due either to a hot plug of an enclosure, or a
power state change of an enclosure. In addition, this message is generated if the daisy chain
order of the enclosures changes.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 3 (Informational)
Trap/EventID 4339
339