Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
DIAG8160
Message PERC Battery
arg1
- incorrect status =
arg2
\n
arg3
.
Arguments
arg1 =
PERC Controller Location
arg2 =
80000000000000??
arg3 =
Error Reason
Detailed
Description
Recommended
Response Action
"If <Error Reason> is (Battery missing or disconnected) then check the battery cable to the
PERC controller. If <Error Reason> is (Replace battery pack) then replace battery pack. If
<Error Reason> is (Remaining capacity low) then battery pack may need to be replaced soon."
Category Storage
SubCategory DIAG = Diagnostic
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
DIAG8166
Message OS - Suspect corrupt MBR, verify MBR with Anti-Virus Application.
Detailed
Description
Recommended
Response Action
Run virus scan.
Category Storage
SubCategory DIAG = Diagnostic
Severity Severity 1 (Critical)
Trap/EventID FALSE