Reference Guide
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CTL75
Message Preserved cache discarded on
arg1
.
Arguments
•
arg1 =
controller name
Detailed
Description
The controller cache was discarded by the user.Data may have been lost or corrupted.
Recommended
Response Action
If data was corrupted or lost, restore the data to the disk from a backup copy.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CTL76
Message A configuration command could not be committed to disk on
arg1
Arguments
•
arg1 =
Controller name
Detailed
Description
The controller encountered errors while applying the configuration on the physical disks. The
configuration command applied has not taken effect.
Recommended
Response Action
Re-issue the failed configuration command or try with a different set of physical disks. Contact
technical support if the problem persists.
266