Reference Guide

BIOS010
Message Lifecycle Controller is not enabled, cannot create Configuration job.
Detailed
Description
For 11G systems: System Services must be enabled to perform the requested operation.
System Services has been disabled through the iDRAC configuration utility accessed by
pressing CTRL+E on boot up or through a remote operation. For 12G systems: Lifecycle
Controller must be enabled to perform the requested operation. Lifecycle Controller has been
disabled by pressing F2 Setup, selecting iDRAC Configuration, and selecting Lifecycle
Controller Settings on boot up or through a remote operation.
Recommended
Response Action
For 11G systems: Use the iDRAC configuration utility to enable the System Services by pressing
on the CTRL+E option on boot up at the targeted system. For 12G systems: Use F2 Setup, select
iDRAC Configuration, and select Lifecycle Controller Settings, to enable the Lifecycle Controller
on boot up of the targeted system.
Category Configuration
SubCategory BIOS = BIOS Management
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
BIOS011
Message Configuration job already created, pending data cannot be deleted
Detailed
Description
Configuration job already created on the specified target. No further command is allowed until
the existing job is completed \n
Recommended
Response Action
Cancel the configuration job or wait for the job to complete. Refer to documentation on job
cancellation.
Category Configuration
SubCategory BIOS = BIOS Management
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE