Reference Guide
BIOS008
Message No pending data present to create a Configuration job
Detailed
Description
No changes are available between the previous configuration and the current configuration.
To create a configuration job, at least one attribute should be changed
Recommended
Response Action
Change the configuration of one or more attributes and then create a configuration job
Category Configuration
SubCategory BIOS = BIOS Management
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
BIOS009
Message Lifecycle Controller is currently in use.
Detailed
Description
Lifecycle Controller cannot gain access to internal storage due to use by another application or
operation.
Recommended
Response Action
Wait for current Lifecycle Controller operation to complete. Verify that the system is 1) Not
currently in Lifecycle Controller Unified Server Configurator 2) Not waiting for user intervention
at F1/F2 POST error 3) Not in any of the device or controller Option ROMs and retry the
operation.
Category Configuration
SubCategory BIOS = BIOS Management
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
190