Reference Guide

BIOS004
Message Invalid parameter value for
arg1
Arguments
arg1 =
attribute name
Detailed
Description
The value for the specified parameter is invalid.
Recommended
Response Action
Verify that parameter values passed to the method are entered as they appear in the
enumeration and parameter data type matches the documentation. \n
Category Configuration
SubCategory BIOS = BIOS Management
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
BIOS005
Message Mismatch in AttributeName and AttributeValue count
Detailed
Description
The number of AttributeName and AttributeValue parameters do not match.
Recommended
Response Action
Enter the same number of parameters for AttributeName and AttributeValue. Refer to
documentation for method input parameter details.
Category Configuration
SubCategory BIOS = BIOS Management
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
188