Reference Guide
Category System Health
SubCategory BAT = Battery Event
Severity Severity 1 (Critical)
Trap/EventID 2225
LCD Message Storage battery is absent. Check battery.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
BAT0010
Message The storage battery for disk drive bay
arg1
is low.
Arguments
•
arg1 =
bay
Detailed
Description
The system has to remain powered on to charge the battery.
Recommended
Response Action
Allow the PERC RAID controller battery for the associated bay to charge. If the issue persists,
contact technical support. Refer to the product documentation to choose a convenient contact
method.
Category System Health
SubCategory BAT = Battery Event
Severity Severity 2 (Warning)
Trap/EventID 2226
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
BAT0011
Message The storage battery for disk drive bay
arg1
is operating normally.
Arguments
•
arg1 =
bay
Detailed
Description
None
176