Reference Guide
Detailed
Description
The PERC RAID controller battery may have failed because of thermal exceptions.
Recommended
Response Action
1) Verify the PERC RAID controller battery installation. 2) Check the system logs for thermal
related issues.
Category System Health
SubCategory BAT = Battery Event
Severity Severity 1 (Critical)
Trap/EventID 2225
LCD Message Storage battery has failed. Check battery.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
BAT0008
Message The storage battery is present.
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory BAT = Battery Event
Severity Severity 3 (Informational)
Trap/EventID 2227
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
BAT0009
Message The storage battery is absent.
Detailed
Description
The PERC RAID controller battery may report absent due to disconnect or thermal exceptions.
Recommended
Response Action
1) Verify the PERC RAID controller battery installation. 2) If installed, reseat or reconnect the
battery and cables. 3) Check the system logs for thermal related issues.
175