Reference Guide
Trap/EventID 2169
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
VLT0235
Message The mezzanine card
arg1arg2
voltage is within range.
Arguments
•
arg1 =
number
•
arg2 =
name
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory VLT = Voltage
Severity Severity 3 (Informational)
Trap/EventID 2171
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
VLT0300
Message CPU
arg1arg2
voltage is less than the lower warning threshold.
Arguments
•
arg1 =
number
•
arg2 =
name
Detailed
Description
Low voltages may be the result of a problem with the voltage regulator or a problem with the
processor. The low voltage may cause the processor to fail to operate.
Recommended
Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.