Reference Guide
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory VLT = Voltage
Severity Severity 3 (Informational)
Trap/EventID 2171
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
VLT0230
Message The mezzanine card
arg1arg2
voltage is less than the lower warning threshold.
Arguments
•
arg1 =
number
•
arg2 =
name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple voltage
exceptions occur consecutively the system may power down in failsafe mode.
Recommended
Response Action
1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the
problem persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health
SubCategory VLT = Voltage
Severity Severity 2 (Warning)
Trap/EventID 2170
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
VLT0231
Message The mezzanine card
arg1arg2
voltage is less than the lower critical threshold.
1480