Reference Guide
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR110
Message Unrecoverable storage medium error detected on
arg1
.
Arguments
•
arg1 =
virtual disk name
Detailed
Description
This alert is generated when an unrecoverable storage medium error is detected on the virtual
disk. This error can be a prelude to the physical disk disk becoming non-functional.
Recommended
Response Action
Make sure a hot spare to the Virtual Disk identified in the message is available and back up the
data on the virtual disk.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR111
Message Corrected disk storage medium error on
arg1
.
Arguments
•
arg1 =
virtual disk name
Detailed
Description
The controller corrected a disk storage medium error on one of the participating physical disks
of the virtual disk identified in the message.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
1395