Reference Guide
Arguments
•
arg1 =
VD Name
Detailed
Description
This alert is provided for informational purposes.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR7
Message
arg1
has failed.
Arguments
•
arg1 =
virtual disk
Detailed
Description
One or more physical disks included in the virtual disk have failed. If the virtual disk is non-
redundant (does not use mirrored or parity data), then the failure of a single physical disk can
cause the virtual disk to fail. If the virtual disk is redundant, then more physical disks have
failed than you can rebuild using mirrored or parity information.
Recommended
Response Action
Create a new virtual disk and restore from a backup.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
Trap/EventID 4353
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE