Reference Guide

Detailed
Description
This alert is provided for informational purposes. The virtual disk has inconsistent data. This
may be caused when a power loss or system shutdown occurs while data is being written to
the virtual disk.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID 4355
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
VDR49
Message
arg1
is permanently degraded.
Arguments
arg1 =
VD Name
Detailed
Description
A redundant virtual disk has lost redundancy. This may occur when the virtual disk suffers the
failure of more than one physical disk. In this case, both the source physical disk and the target
disk with redundant data have failed. A rebuild is not possible because there is no longer
redundancy.
Recommended
Response Action
Replace the failed disks and restore from backup.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
1377