Reference Guide
58
VDR Event Messages
VDR1
Message
arg1
failed.
Arguments
•
arg1 =
VD Name
Detailed
Description
A storage component such as a physical disk or an enclosure has failed. The failed component
may have been identified by the controller while performing a task such as a rescan or a check
consistency.
Recommended
Response Action
Replace the failed component. You can identify which component has failed by locating the
component that has a red "X" for its status. Perform a rescan after replacing the failed
component.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR10
Message Formatting the
arg1
has started.
Arguments
•
arg1 =
VD Name
Detailed
Description
This alert is provided for informational purposes.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
1355