Reference Guide
55
TMPS Event Messages
TMPS0100
Message Inlet temperature is above warning level for extended duration.
Detailed
Description
Inlet temperature has been above the warning threshold for duration of 8% or more for the
operational time during the last one year.
Recommended
Response Action
This condition will occur if the ambient temperature is high. Make sure the ambient
temperature of the environment is in normal range.
Category System Health
SubCategory TMPS = Temperature Statistics
Severity Severity 2 (Warning)
Trap/EventID 2522
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
TMPS0101
Message Inlet temperature is above critical level for extended duration.
Detailed
Description
Inlet temperature has been above the critical threshold for duration of 0.8% or more for the
operational time during the last one year.
Recommended
Response Action
This condition will occur if the ambient temperature is high. Make sure the ambient
temperature of the environment is in normal range.
Category System Health
SubCategory TMPS = Temperature Statistics
Severity Severity 2 (Warning)
Trap/EventID 2522
LCD Message No LCD message display defined.
Initial Default. FALSE
1335