Reference Guide
BAR073
Message Delete of vFlash Backup partition unsuccessful.
Detailed
Description
Deleting the vFlash backup partition failed.
Recommended
Response Action
Enable and initialize the vFlash media and retry the export. If the error continues, try a new
vFlash media or use the network share option(s).
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
BAR074
Message Unable to collect Firmware Inventory information.
Detailed
Description
The collection and export of firmware inventory data failed.
Recommended
Response Action
Apply the Dell Update Package for Unified Server Configurator (USC). If collect system
inventory on reboot (CSIOR) is not enabled, enter and exit System Services in USC to update
the database, reboot the system and try the operation again. If the error continues, use the
field service repair software to repair the Lifecycle Controller. Download all Dell Update
Packages for USC, Diagnostics Driver Packs, and device firmware for all host system devices,
install all packages and retry the operation.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
123