Reference Guide

SubCategory SWC = Software Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC0060
Message Unable to complete the operation.
Detailed
Description
One or more vFlash partitions are attached.
Recommended
Response Action
Use iDRAC Web interface to detach the vFlash partitions and retry the operation.
Category Configuration
SubCategory SWC = Software Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC0061
Message Unable to complete the operation.
Detailed
Description
Write-protection is enabled on the vFlash SD card.
Recommended
Response Action
Remove the write-protection on the vFlash SD card and retry the operation.
Category Configuration
SubCategory SWC = Software Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
1179