Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC0050
Message Unable to initiate Import operation.
Detailed
Description
Unable to initiate Import operation since iDRAC is not responding.
Recommended
Response Action
Retry the Import operation using a valid backup image file and the correct passphrase. If the
problem persists, do the following: 1) Turn off the system and disconnect the power cord. 2)
Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the
operation.
Category Configuration
SubCategory SWC = Software Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC0051
Message Unable to retrieve iDRAC license information.
Detailed
Description
Unable to retreive license information due to an iDRAC communication error.
Recommended
Response Action
Exit Lifecycle Controller and retry the operation. If the problem persists, do the following: 1)
Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the
power cord, turn on the system, and retry the operation.
Category Configuration
SubCategory SWC = Software Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
1174