Reference Guide

Detailed
Description
The device (physical disk or an enclosure) identified in the message has failed. The device
(physical disk or an enclosure) failure was detected while performing a rescan. However,
physical disk failures are also detected during a check consistency operation.
Recommended
Response Action
Replace the identified device. A failed device is inidicated with a red color "X" status icon.
Perform a rescan after replacing the failed device.
Category Storage
SubCategory STOR = Storage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
STOR0501
Message Unable to configure RAID.
Detailed
Description
Unable to create a virtual disk due to unknown reasons.
Recommended
Response Action
Do one of the following and retry the operation: 1) Exit the RAID Configuration wizard. 2) Update
the RAID controller firmware to the latest version. 3) Reboot the system and press the <F10>
key to re-enter Lifecycle Controller, and retry the operation.
Category Storage
SubCategory STOR = Storage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
STOR0502
Message Unable to launch RAID Configuration wizard.
1084