Reference Guide

Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SEL1511
Message Member
arg1
removed from the Chassis Group.
Arguments
arg1 =
number
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory SEL = Sys Event Log
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SEL9900
Message An unsupported event occurred.
Detailed
Description
The current software version cannot decode this event. The source of the event may come
from a source that is not compatible with this software or the event may have been added after
the release of this software. You may need to review this event using a tool which displays raw
data such as Ipmitool with the -vvv option or Racadm with the -E option.
Recommended
Response Action
Upgrade Management Software
Category System Health
SubCategory SEL = Sys Event Log
Severity Severity 3 (Informational)
1039