Dell Event Messages Reference Guide Version 3.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2013 Dell Inc.
Contents 1 Introduction................................................................................................................................73 2 AMP Event Messages.............................................................................................................. 75 AMP0300.................................................................................................................................................................75 AMP0301..............................................
ASR0003.................................................................................................................................................................. 92 ASR0008.................................................................................................................................................................. 93 ASR0009...............................................................................................................................................................
BAR050..................................................................................................................................................................112 BAR052..................................................................................................................................................................113 BAR053..................................................................................................................................................................
BAR008..................................................................................................................................................................132 BAR010..................................................................................................................................................................133 BAR012..................................................................................................................................................................
BAR109..................................................................................................................................................................152 5 BAT Event Messages............................................................................................................. 153 BAT1000................................................................................................................................................................ 153 BAT1001..........................
BAT0004................................................................................................................................................................ 173 BAT0005................................................................................................................................................................ 174 BAT0006................................................................................................................................................................
7 BOOT Event Messages...........................................................................................................197 BOOT001............................................................................................................................................................... 197 BOOT002............................................................................................................................................................... 197 BOOT003...............................
CPU0025................................................................................................................................................................ 217 CPU0700................................................................................................................................................................ 217 CPU0701................................................................................................................................................................
CTL28.....................................................................................................................................................................238 CTL29.....................................................................................................................................................................239 CTL3................................................................................................................................................................
CTL66.....................................................................................................................................................................261 CTL67.....................................................................................................................................................................261 CTL68...............................................................................................................................................................
DH007....................................................................................................................................................................283 DH008....................................................................................................................................................................284 DH009.................................................................................................................................................................
DIAG8158.............................................................................................................................................................. 307 DIAG8160.............................................................................................................................................................. 308 DIAG8166..............................................................................................................................................................
ENC15....................................................................................................................................................................328 ENC16....................................................................................................................................................................328 ENC17.................................................................................................................................................................
FAN0009................................................................................................................................................................ 351 FAN0010................................................................................................................................................................ 351 FAN0011................................................................................................................................................................
HWC1003...............................................................................................................................................................374 HWC1004...............................................................................................................................................................375 HWC1005...............................................................................................................................................................
HWC4011...............................................................................................................................................................395 HWC4012...............................................................................................................................................................396 HWC4013...............................................................................................................................................................
HWC8005...............................................................................................................................................................417 HWC8006...............................................................................................................................................................418 HWC8007...............................................................................................................................................................
JCP027.................................................................................................................................................................. 438 JCP028.................................................................................................................................................................. 439 23 LC Event Messages...............................................................................................................441 LC001.........................
LC039.....................................................................................................................................................................458 LC040.....................................................................................................................................................................459 LC041...............................................................................................................................................................
LIC005....................................................................................................................................................................479 LIC006....................................................................................................................................................................480 LIC007..............................................................................................................................................................
LOG322.................................................................................................................................................................. 500 LOG323.................................................................................................................................................................. 500 LOG324................................................................................................................................................................
MEM1009.............................................................................................................................................................. 522 MEM1010.............................................................................................................................................................. 523 MEM1011..............................................................................................................................................................
NIC006...................................................................................................................................................................544 NIC007...................................................................................................................................................................545 NIC008................................................................................................................................................................
OSD13................................................................................................................................................................... 564 OSD14................................................................................................................................................................... 565 OSD15.................................................................................................................................................................
OSD55................................................................................................................................................................... 584 OSD56................................................................................................................................................................... 584 OSD57.................................................................................................................................................................
PCI1322................................................................................................................................................................. 605 PCI1342................................................................................................................................................................. 605 PCI1344...............................................................................................................................................................
PDR13....................................................................................................................................................................626 PDR14....................................................................................................................................................................626 PDR15.................................................................................................................................................................
PDR52....................................................................................................................................................................649 PDR53....................................................................................................................................................................649 PDR54.................................................................................................................................................................
PDR95....................................................................................................................................................................671 PDR96....................................................................................................................................................................671 PDR97.................................................................................................................................................................
PDR210..................................................................................................................................................................693 PDR211..................................................................................................................................................................694 PDR212..................................................................................................................................................................
PR27...................................................................................................................................................................... 714 PR28...................................................................................................................................................................... 714 PR29..............................................................................................................................................................
PSU0000................................................................................................................................................................ 733 PSU0001................................................................................................................................................................ 734 PSU0002................................................................................................................................................................
PSU0910................................................................................................................................................................ 755 PSU0911................................................................................................................................................................ 756 PSU0912................................................................................................................................................................
PWR1009...............................................................................................................................................................778 PWR2000...............................................................................................................................................................778 PWR2001...............................................................................................................................................................
RAC0506................................................................................................................................................................ 798 RAC0507................................................................................................................................................................ 798 RAC0508................................................................................................................................................................
RAC0116................................................................................................................................................................ 818 RAC0117................................................................................................................................................................ 818 RAC0118................................................................................................................................................................
RAC0209................................................................................................................................................................ 837 RAC0211................................................................................................................................................................ 837 RAC0212................................................................................................................................................................
RAC0257................................................................................................................................................................ 856 RAC0259................................................................................................................................................................ 857 RAC0260................................................................................................................................................................
RAC0801................................................................................................................................................................ 876 RAC053..................................................................................................................................................................876 RAC052..................................................................................................................................................................
RAC940..................................................................................................................................................................895 RAC941..................................................................................................................................................................896 RAC942..................................................................................................................................................................
RAC982..................................................................................................................................................................915 RAC983..................................................................................................................................................................915 RAC984..................................................................................................................................................................
RAC1020................................................................................................................................................................ 935 RAC1021................................................................................................................................................................ 935 RAC1023................................................................................................................................................................
RDU0015................................................................................................................................................................955 RDU0020................................................................................................................................................................955 RDU0021................................................................................................................................................................
RFL2003................................................................................................................................................................. 976 RFL2004................................................................................................................................................................. 976 RFL2005...............................................................................................................................................................
RSI0002................................................................................................................................................................. 997 RSI0003................................................................................................................................................................. 998 RSI0004...............................................................................................................................................................
SEC0052...............................................................................................................................................................1016 SEC0700...............................................................................................................................................................1016 SEC0701...............................................................................................................................................................
SEL1504............................................................................................................................................................... 1036 SEL1506............................................................................................................................................................... 1036 SEL1507...............................................................................................................................................................
STOR015..............................................................................................................................................................1057 STOR016..............................................................................................................................................................1058 STOR017..............................................................................................................................................................
STOR0200............................................................................................................................................................ 1077 STOR0201............................................................................................................................................................ 1078 STOR0202............................................................................................................................................................
SUP003................................................................................................................................................................1098 SUP005................................................................................................................................................................1098 SUP006................................................................................................................................................................
SUP0532.............................................................................................................................................................. 1118 SUP0533.............................................................................................................................................................. 1118 SUP0534..............................................................................................................................................................
SUP1903.............................................................................................................................................................. 1137 SUP1904.............................................................................................................................................................. 1138 SUP1905..............................................................................................................................................................
SWC0015.............................................................................................................................................................1157 SWC0016.............................................................................................................................................................1157 SWC0017.............................................................................................................................................................
SWC0056.............................................................................................................................................................1176 SWC0057.............................................................................................................................................................1177 SWC0034.............................................................................................................................................................
SWC0282.............................................................................................................................................................1196 SWC0283.............................................................................................................................................................1197 SWC0284.............................................................................................................................................................
SWC0324.............................................................................................................................................................1216 SWC0101.............................................................................................................................................................1216 SWC0102.............................................................................................................................................................
SWC0142.............................................................................................................................................................1235 SWC0143.............................................................................................................................................................1236 SWC0144.............................................................................................................................................................
SWC0223.............................................................................................................................................................1255 SWC0224.............................................................................................................................................................1255 SWC0225.............................................................................................................................................................
SYS106................................................................................................................................................................ 1275 SYS107................................................................................................................................................................ 1276 SYS108................................................................................................................................................................
SYS062................................................................................................................................................................ 1296 SYS063................................................................................................................................................................ 1297 SYS064................................................................................................................................................................
TMP0118............................................................................................................................................................. 1317 TMP0119............................................................................................................................................................. 1318 TMP0120.............................................................................................................................................................
UEFI0002..............................................................................................................................................................1338 UEFI0003..............................................................................................................................................................1338 UEFI0004..............................................................................................................................................................
VDR13..................................................................................................................................................................1357 VDR14..................................................................................................................................................................1357 VDR15..................................................................................................................................................................
VDR51..................................................................................................................................................................1379 VDR52..................................................................................................................................................................1379 VDR53..................................................................................................................................................................
VF008...................................................................................................................................................................1400 VF009...................................................................................................................................................................1401 VF010.................................................................................................................................................................
VF050...................................................................................................................................................................1419 VF051...................................................................................................................................................................1420 VF052.................................................................................................................................................................
VFL0007............................................................................................................................................................... 1440 VFL0008............................................................................................................................................................... 1441 VFL0009...............................................................................................................................................................
VFLA1000.............................................................................................................................................................1459 62 VLT Event Messages.......................................................................................................... 1461 VLT0100............................................................................................................................................................... 1461 VLT0101.............................
VLT0233............................................................................................................................................................... 1482 VLT0234............................................................................................................................................................... 1482 VLT0235...............................................................................................................................................................
1 Introduction The Event Message Reference contains the error and event information generated by firmware and other agents that monitor system components. These events might be logged, presented to the user on one of the system management consoles, or both logged and displayed. Each event consists of the following fields: Message ID Message The unique alphanumeric identifier for the event.
Severity 3 Information Indicates a medium-to-low impact problem that involves a partial or noncritical loss of functionality; operations are impaired but can continue to function. LCD Message The event message text that is displayed on the system's LCD. Initial Default Event messages result in event actions such as logging, SNMP or email alerts. Generally, the event actions are configurable using the Dell iDRAC event action filtering feature.
2 AMP Event Messages AMP0300 The system boardarg1current is less than the lower warning threshold. Message Arguments • arg1 = name Detailed Description None Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes. Category System Health SubCategory AMP = Amperage Severity Severity 2 (Warning) Trap/EventID 2178 LCD Message No LCD message display defined. Initial Default.
Trap/EventID 2177 LCD Message System board current is outside of range. Contact Support Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE AMP0302 The system boardarg1current is greater than the upper warning threshold. Message Arguments • arg1 = name Detailed Description Product documentation contains information on correct configuration.
Severity Severity 1 (Critical) Trap/EventID 2177 LCD Message System board current is outside of range. Contact Support Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE AMP0304 The system boardarg1current is outside of range. Message Arguments • arg1 = name Detailed Description Product documentation contains information on correct configuration.
SubCategory AMP = Amperage Severity Severity 3 (Informational) Trap/EventID 2179 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE AMP0306 Disk drive bayarg1current is less than the lower warning threshold.
Category System Health SubCategory AMP = Amperage Severity Severity 1 (Critical) Trap/EventID 2177 LCD Message Disk drive bay current is outside of range. Contact Support Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE AMP0308 Disk drive bayarg1current is greater than the upper warning threshold.
Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes. Category System Health SubCategory AMP = Amperage Severity Severity 1 (Critical) Trap/EventID 2177 LCD Message Disk drive bay current is outside of range. Contact Support Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory AMP = Amperage Severity Severity 3 (Informational) Trap/EventID 2179 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE AMP0312 Message System level current is less than the lower warning threshold.
Category System Health SubCategory AMP = Amperage Severity Severity 1 (Critical) Trap/EventID 2177 LCD Message System level current is outside of range. Contact Support Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE AMP0314 Message System level current is greater than the upper warning threshold.
Trap/EventID 2177 LCD Message System level current is outside of range. Contact Support Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE AMP0316 Message System level current is outside of range. Detailed Description Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE AMP0318 Message Chassis power level current is less than the lower warning threshold.
AMP0320 Message Chassis power level current is greater than the upper warning threshold. Detailed Description Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded.
Detailed Description Product documentation contains information on correct configuration. The failure could also be caused by a faulty component or related cabling. System performance may be degraded. Recommended Response Action Review system power policy, check system logs for power related failures, and review system configuration changes Category System Health SubCategory AMP = Amperage Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined.
Detailed Description The current sensor identified in the message has failed. This condition can cause system performance issues and degradation in the moitoring capability of the system. Recommended Response Action Check the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
Arguments • • arg1 = sensor name arg2 = current Detailed Description The current sensor identified in the message has returned to a normal state. Recommended Response Action No response action is required. Category System Health SubCategory AMP = Amperage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE AMP405 Thearg1sensor state has changed to a failed state with a value ofarg2A. Message Arguments • • arg1 = sensor name arg2 = current Detailed Description The current sensor identified in the message may be faulty. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
3 ASR Event Messages ASR0000 Message The watchdog timer expired. Detailed Description The operating system or potentially an application failed to communicate to the baseboard management controller (BMC) within the timeout period. Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE ASR0002 Message The watchdog timer powered off the system. Detailed Description The operating system or an application failed to communicate to the baseboard management controller (BMC). The system powered off per the configured setting.
ASR0008 Message The watchdog timer interrupt was initiated. Detailed Description The operating system or an application failed to communicate to the baseboard management controller (BMC) within the timeout period. The BMC invoked a system interrupt. (IPMI sensor type code 23h - offset 00h) Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
ASR0100 Message The BIOS watchdog timer reset the system. Detailed Description The operating system or an application failed to communicate to the system board within the timeout period. The system was reset per the configured setting. (IPMI sensor type code 23h offset 01h event 3:0 - 2h) Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
ASR0102 Message The OS watchdog timer shutdown the system. Detailed Description The operating system or an application failed to communicate within the timeout period. The system was shutdown. (IPMI sensor type code 23h offset - 02h event 3:0 - 4h) Recommended Response Action Check the operating system, application, hardware, and system event log for exception events.
Detailed Description The operating system or an application failed to communicate within the timeout period. The system was powered cycled. (IPMI sensor 23h offset - 03h event 3:0 - 4h) Recommended Response Action Check the operating system, application, hardware, and system event log for exception events. Category System Health SubCategory ASR = Auto Sys Reset Severity Severity 1 (Critical) Trap/EventID 2233 LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory ASR = Auto Sys Reset Severity Severity 1 (Critical) Trap/EventID 2233 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE ASR0107 Message The OS watchdog timer pre-timeout interrupt was initiated.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE ASR200 The watchdog timer expired atarg1.
SubCategory ASR = Auto Sys Reset Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE ASR202 The watchdog timer turned off the system atarg1.
Recommended Response Action To determine the correct cause of the exception, contact your service provider Category System Health SubCategory ASR = Auto Sys Reset Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
4 BAR Event Messages BAR001 Message Export System Profile requested. Detailed Description A system profile export has been requested. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR007 Message Export System Profile completed. Detailed Description System profile exported. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
BAR011 Message Unable to collect Hardware Inventory information. Detailed Description Hardware Inventory data collection and export has failed. Recommended Response Action Enter system services to enter Unified Server Configurator (USC), and select exit and reboot option in USC to instantiate the database, if Collect System Inventory on Restart (CSIOR) is not enabled. If the hardware inventory database is present, reboot the Integrated Remote Access Controller (iDRAC)and retry.
BAR015 Message Backup file data processing error. Detailed Description The Backup file information was not properly processed and the operation cannot continue. This can be due to resource constraints within the processing environment. If the network share is read only, this error will be thrown also. Recommended Response Action If this is backup to network share, check to make sure network share is read/write accessible. Reboot the Integrated Remote Access Controller and retry the operation.
BAR019 Message Validating Restore operation, allow several minutes for to complete. Detailed Description A system profile backup file validation is in progress. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The process is entering the component update phase of the restore operation. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR029 Message Restoring Integrated Remote Access Controller firmware.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR033 Message Unable to Restore Lifecycle Controller data. Detailed Description Lifecycle Controller data import has failed. Recommended Response Action 1. Download and apply the Dell Update Package for the Unified Server Configurator (USC). 2.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR036 Message System Reset or Lifecycle Controller Actions Canceled, System Profile Failure Recovery initiated. Detailed Description A system profile import failed and has left the system in an unusable state. Attempting to setup the environment for normal operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR040 Message Unable to access vFlash. Detailed Description Access to the vFlash Card is not possible, or has been denied. Recommended Response Action Make sure the vFlash is enabled, not write protected, and initialized. Then try the operation again.
BAR044 Message Waiting for Host System Shutdown to finish. Detailed Description Polling to allow the host system to shut down before proceeding. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
BAR048 Message System Service Tag not present. Detailed Description The Host System motherboard does not has an assigned Service Tag, preventing the operation. Recommended Response Action Perform a System Profile import from a previously backup file. If no backup file is available contact hardware vendor. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
BAR052 Firmware update cannot be performed for Device:arg1 Message Arguments • arg1 = device name Detailed Description The required device firmware was not found, and the update will not occur. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR054 Message System Reset or Lifecycle Controller Actions Canceled, System Profile Failure Recovery unsuccessful. Detailed Description The attempt to clean up after a failed Backup/Restore of a system profile operation has failed.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR056 Component Configuration Restored on Device :arg1 Message Arguments • arg1 = device name Detailed Description The configuration import was successful for the specified device. Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR058 Message Validating NFS destination access. Detailed Description The system profile export/import network destination is being checked for access. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR060 Message Collecting Firmware Inventory information. Detailed Description Collecting firmware inventory and placing it in the export backup file. Recommended Response Action No response action is required.
BAR062 Message Collecting Lifecycle Controller Configuration database. Detailed Description Collecting the Lifecycle Controller configuration database and placing it in the export backup file. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Collecting the Integrated Remote Access Controller firmware and placing it in the export backup file. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR067 Message vFlash media not initialized. Detailed Description The system profile export destination is not initialized.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR069 Message Insufficient space on vFlash media. Detailed Description The system profile export failed as there is insufficient space on the vFlash media.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR071 Message CIFS Destination access denied. Detailed Description Access to the CIFS export/import destination is not possible or has been denied. Recommended Response Action Verify that the input parameters are correct, connectivity exists to the destination end point, and retry the operation.
BAR073 Message Delete of vFlash Backup partition unsuccessful. Detailed Description Deleting the vFlash backup partition failed. Recommended Response Action Enable and initialize the vFlash media and retry the export. If the error continues, try a new vFlash media or use the network share option(s). Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
BAR075 Message Unable to collect System information. Detailed Description The collection and export of system information failed. Recommended Response Action Restart the remote access controller, and retry the operation. If the error continues, use the remote access controller firmware to try the operation again. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
BAR077 Message Unable to collect the Firmware images. Detailed Description The collection and export of host system firmware images failed. Recommended Response Action Apply Dell Update Packages for all devices and software, and try the operation again. If the error continues, repair the Lifecycle Controller and apply the packages again, and retry the operation.
BAR079 Message Unable to collect the Integrated Remote Access Controller configuration. Detailed Description The collection and export of Integrated Remote Access Controller configuration failed. Recommended Response Action Apply the integrated remote access controller firmware, manually set the configuration attributes, and try the operation again.
Detailed Description Importing the Lifecycle Controller firmware image data is from the system profile backup file. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Obtain a valid host system backup image and try the operation again. Reboot the remote access controller and try the operation again. If the error continues, download a new remote access controller firmware image and try the operation again. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR086 Message Unable to Restore The Lifecycle Controller Configuration database.
Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR088 Message No partitions available on vFlash media. Detailed Description The maximum number of partitions are already in use.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR004 Message Collecting Hardware Inventory information. Detailed Description Hardware Inventory data is being collected and copied into the backup file. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR006 Message Finalizing Backup file. Detailed Description The system profile backup file is being finalized and closed. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
BAR010 Message Unable to create Backup partition on vFlash media. Detailed Description Backup partition creation has failed. Recommended Response Action Make sure that the vFlash media is not write-protected. Enable and initialize the vFlash media, retry backup. If that fails Try new vFlash media or use the Network Share option(s). Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined.
BAR014 Message Backup file or partition access error. Detailed Description The ability to access the Backup file has been lost. The operation cannot continue. This can be due to a media error or loss of connectivity. Recommended Response Action if vFlash media replace media and try again. If a network share, make sure there is connectivity to and existence of the destination.
Detailed Description A system profile backup file validation request has completed. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR024 Message Initializing Restore operation. Detailed Description The restoration environment is being initialized.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR028 Message Host System Component Restore completed with errors, shutting down Host System. Detailed Description The component restoration on the host system has completed, but there were errors. The Host System will shutdown.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR032 Message Invalid Backup file. Detailed Description The system profile backup file validation has failed. Recommended Response Action 1. An incorrect passphrase may have been entered, correct the input and retry the operation. 2. Download a valid backup image of the host system and retry. 3.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR037 Message System Reset or Lifecycle Controller Actions Canceled, System Profile Failure Recovery completed. Detailed Description Adjustments to Lifecycle and Integrated Remote Access Controller environments are complete. Recommended Response Action No response action is required.
BAR041 Message System Shutdown. Detailed Description Shutting down host system. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The host system is powering down to facilitate the import of the Integrated Remote Access Controller system profile. Recommended Response Action No response action is required. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action As indicated by the job status, wait for restore to complete. After the status displays Complete or Failed, wait for a few minutes for the Integrated Remote Access Controller (iDRAC) to restart. After restart, power on the Host System using iDRAC. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Obtain the Dell update package for the Unified Server Configurator and apply it. Then perform a Backup operation to save this data, for later restore. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SubCategory BAR = Backup/Restore Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR092 Message Disconnect from NFS unsuccessful. Detailed Description The attempt to disconnect from the user supplied NFS location has failed.
SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR094 Message Another Backup operation already in progress. Detailed Description The request to create a System Profile Backup file has failed as there is already a request in progress.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR096 Message BIOS incompatibility detected. Detailed Description The current BIOS firmware installed on the system does not have Backup and Restore feture support.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR098 Message Invalid System Service Tag. Detailed Description The Service Tag installed on the system is invalid. The Backup and Restore feature will not operate without a valid Service Tag.
BAR100 Message Unable to collect License data. Detailed Description An error occurred accessing license data. Cannot collect license data to copy to Server Profile backup file. Recommended Response Action Refer to License Management documentation for re-installation of license(s) instructions and retry the operation. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Cannot import license data from the backup Server Profile. Recommended Response Action Refer to iDRAC User Guide documentation license installation instructions and retry the operation. Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory BAR = Backup/Restore Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR105 Message Restoring system branding data. Detailed Description Importing system branding data from the Server Profile backup file.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR107 Message vFlash media reader license not present. Detailed Description The vFlash media reader requires a license to function. Recommended Response Action Obtain the license for vFlash media from the service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE BAR109 Message OEMDRV partition is in use. Detailed Description The OEMDRV partition is mounted for performing operating system deployment use. This situation prevents the Export and Import Server Profile operation from continuing. Recommended Response Action Dismount the OEMDRV partition by selecting F10 during boot and retry the operation.
5 BAT Event Messages BAT1000 Battery onarg1is missing. Message Arguments • arg1 = controller name Detailed Description The controller cannot communicate with the battery. The battery is absent or improperly connected. A battery with a weak or depleted charge may also cause this message. Recommended Response Action Verify that the device is present and then check the cables. See the storage hardware documentation to verify cabling.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BAT1002 The battery onarg1learn cycle has started. Message Arguments • arg1 = Controller name Detailed Description This alert is provided for informational purposes.
SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID 4275 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE BAT1004 The battery onarg1learn cycle has timed out.
Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BAT1006 The battery onarg1learn cycle will start inarg2days.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = controller name Detailed Description The controller battery health has returned to normal. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID 4275 LCD Message No LCD message display defined. Initial Default.
BAT1011 Battery onarg1is in warn only mode and requires reconditioning. Message Arguments • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BAT1013 Recharge count has exceeded the maximum limit for battery onarg1. Message Arguments • arg1 = Controller name Detailed Description The battery cannot be recharged further. Recommended Response Action Replace the battery pack.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BAT1015 arg1battery charge process is interrupted. Message Arguments • arg1 = Controller name Detailed Description Diagnostic event for service to determine if there is an ambient temperature problem. Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BAT1017 Thearg1battery learn mode has changed to Warn. Message Arguments • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BAT1019 Battery onarg1is charging. Message Arguments • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID 4275 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE BAT1021 The charge level for the battery onarg1is below the normal threshold.
Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BAT1023 The charge level for the battery onarg1is within normal limits.
Recommended Response Action Contact technical support. Category Storage SubCategory BAT = Battery Event Severity Severity 2 (Warning) Trap/EventID 4274 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE BAT1025 arg1is unable to recover cached data from the Battery Backup Unit (BBU).
Arguments • arg1 = controller name Detailed Description The controller has retrieved cached data. Recommended Response Action No response action is required. Category Storage SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID 4275 LCD Message No LCD message display defined. Initial Default.
BAT1028 The battery voltage onarg1is low. Message Arguments • arg1 = controller name Detailed Description The controller battery voltage is low. This may indicate that the battery is no longer protecting the controller cache. Recommended Response Action The battery needs to recharged. Wait 24 hours to see if the charge is restored. Category Storage SubCategory BAT = Battery Event Severity Severity 2 (Warning) Trap/EventID 4274 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE BAT1030 Thearg1battery charge level is normal. Message Arguments • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE BAT1032 The battery temperature onarg1is normal. Message Arguments • arg1 = controller name Detailed Description The battery temperature is within the normal operating range. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID 4274 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE BAT1034 The battery properties forarg1have changed. Message Arguments • arg1 = controller name Detailed Description One or more battery properties were modified. Recommended Response Action No response action is required.
Trap/EventID 2226 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE BAT0001 Message The system board battery is operating normally. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE BAT0003 Message The system board battery is present. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID 2227 LCD Message No LCD message display defined. Initial Default.
BAT0005 Message The storage battery is low. Detailed Description The system has to remain powered on to charge the battery. Recommended Response Action Allow the PERC RAID controller battery to charge. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory BAT = Battery Event Severity Severity 2 (Warning) Trap/EventID 2226 LCD Message No LCD message display defined. Initial Default.
Detailed Description The PERC RAID controller battery may have failed because of thermal exceptions. Recommended Response Action 1) Verify the PERC RAID controller battery installation. 2) Check the system logs for thermal related issues. Category System Health SubCategory BAT = Battery Event Severity Severity 1 (Critical) Trap/EventID 2225 LCD Message Storage battery has failed. Check battery. Initial Default.
Category System Health SubCategory BAT = Battery Event Severity Severity 1 (Critical) Trap/EventID 2225 LCD Message Storage battery is absent. Check battery. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE BAT0010 The storage battery for disk drive bayarg1is low.
Recommended Response Action Verify the battery installation, check the system logs for thermal related issues. Category System Health SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID 2227 LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory BAT = Battery Event Severity Severity 3 (Informational) Trap/EventID 2227 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE BAT0014 The storage battery for disk drive bayarg1is absent.
Arguments • arg1 = name Detailed Description System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the battery at the next service window. Category System Health SubCategory BAT = Battery Event Severity Severity 2 (Warning) Trap/EventID 2226 LCD Message No LCD message display defined. Initial Default.
BAT0017 Thearg1battery has failed. Message Arguments • arg1 = name Detailed Description System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the battery. Category System Health SubCategory BAT = Battery Event Severity Severity 1 (Critical) Trap/EventID 2225 LCD Message The battery has failed. Check battery. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE BAT0019 Thearg1battery is absent. Message Arguments • arg1 = name Detailed Description System settings may be preserved if input power is not removed from the power supplies. Recommended Response Action Check the battery to confirm presence.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BAT0031 Message The system board battery status is unknown. Detailed Description The system battery level is unknown, and if the input power is disconnected, the system settings will not be preserved. Recommended Response Action Replace the the battery.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BAT1036 The battery onarg1is discharging. Message Arguments • arg1 = controller name Detailed Description The battery on the controller identified in the message is being discharged. Recommended Response Action No response action is required.
6 BIOS Event Messages BIOS101 Message Unable to read or change any of the system BIOS configuration settings. Detailed Description The system configuration data that BIOS exposes to Server Administrator is malformed or not available and Server Administrator is unable to read or change any of the system BIOS configuration setttings. Recommended Response Action Power cycle the system and retry the operation. If the problem persists, reinstall the BIOS firmware Update Package.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BIOS102 Message A system BIOS update is scheduled that requires a reboot. Detailed Description A BIOS update job is scheduled through the remote access controller, and the system must be rebooted to apply the update. Recommended Response Action Reboot the system to apply the BIOS update.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BIOS002 Message Resource allocation failure. Detailed Description Unable to allocate required memory to perform the requested operation; see the inserted comment. Recommended Response Action Power cycle system and reapply firmware packages for Lifecycle Controller and iDRAC.
BIOS004 Invalid parameter value forarg1 Message Arguments • arg1 = attribute name Detailed Description The value for the specified parameter is invalid. Recommended Response Action Verify that parameter values passed to the method are entered as they appear in the enumeration and parameter data type matches the documentation. \n Category Configuration SubCategory BIOS = BIOS Management Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined.
BIOS006 Message Configuration job already created, cannot set attribute on specified target until existing job is completed or is cancelled Detailed Description Configuration job already created on the specified target. No further command is allowed until the existing job succeeds or the job is cancelled \n Recommended Response Action Wait for the job to complete; to continue with more sets on the specified target, cancel the job and proceed.
BIOS008 Message No pending data present to create a Configuration job Detailed Description No changes are available between the previous configuration and the current configuration.
BIOS010 Message Lifecycle Controller is not enabled, cannot create Configuration job. Detailed Description For 11G systems: System Services must be enabled to perform the requested operation. System Services has been disabled through the iDRAC configuration utility accessed by pressing CTRL+E on boot up or through a remote operation. For 12G systems: Lifecycle Controller must be enabled to perform the requested operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BIOS012 Message No pending data to delete. Detailed Description No changes to BIOS attribute data are available between the previous configuration and the current configuration. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BIOS014 Invalid AttributeValue for AttributeName:arg1 Message Arguments • arg1 = attribute name Detailed Description AttributeValue may be invalid because of the following causes: \n1. Length of new AttributeValue is not within minLength and maxLength \n2. Value of new AttributeValue is not within LowerBound and UpperBound \n3.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BIOS016 AttributeValue cannot be changed for disabled AttributeNamearg1. Message Arguments • arg1 = attribute name Detailed Description A set attribute operation was attempted on a disabled attribute. Recommended Response Action No response action is required.
Initial Default.
7 BOOT Event Messages BOOT001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration SubCategory BOOT = BOOT Control Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BOOT003 Message Method not supported Detailed Description This operation is not supported on the current configuration.
BOOT005 Message Missing required parameter. Detailed Description One or more of the invoked methods required parameters are missing. Recommended Response Action Check documentation for the method in question and try again. Category Configuration SubCategory BOOT = BOOT Control Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description One or more of the Boot Source instance IDs does not belong to the affected Boot Configuration. Recommended Response Action ChangeBootOrderByInstanceID only accepts Boot Sources from the impacted Boot Configuration. Verify that all source arguments belong to the desired Boot Configuration. Category Configuration SubCategory BOOT = BOOT Control Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Verify that Boot Sources for the indicated Boot Configuration are displaying when enumerating DCIM_BootSourceSetting. Power cycle system and reapply firmware packages for Lifecycle Controller and iDRAC. Category Configuration SubCategory BOOT = BOOT Control Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SubCategory BOOT = BOOT Control Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE BOOT012 Message Job started to attach and set vFlash SD card partition for OneTime boot.
LCD Message No LCD message display defined. Initial Default.
8 CBL Event Messages CBL0001 Backplanearg1power cable disconnected. Message Arguments • arg1 = Bay ID Detailed Description A backplane signal cable was detected, but the accompanying power cable was not present. Recommended Response Action Check backplane configuration. Re-connect cable. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE TRUE FALSE FALSE FALSE FALSE CBL0003 Backplanearg1connectorarg2disconnected. No cable detected. Message Arguments • • arg1 = Bay ID arg2 = Connector Name Detailed Description None Recommended Response Action Check backplane configuration. Re-connect cable.
Category System Health SubCategory CBL = Cable Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE TRUE FALSE FALSE FALSE FALSE CBL0005 Backplanearg1connectorarg2incorrectly connected to motherboard SATA controller.
Recommended Response Action Review product documentation. Check backplane configuration. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory CBL = Cable Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
9 CPU Event Messages CPU0000 CPUarg1has an internal error (IERR). Message Arguments • arg1 = number Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action Review System Event Log and Operating System Logs. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Trap/EventID 2241 LCD Message CPU has a thermal trip. Check CPU heat sink Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE CPU0002 CPUarg1has failed the built-in self-test (BIST). Message Arguments • arg1 = number Detailed Description None Recommended Response Action 1) Turn system off and remove input power for one minute.
Category System Health SubCategory CPU = Processor Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE CPU0004 CPUarg1failed to initialize.
Recommended Response Action Review product documentation for supported CPU configurations. Category System Health SubCategory CPU = Processor Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message CPU configuration is unsupported. Check CPU or BIOS revision Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory CPU = Processor Severity Severity 3 (Informational) Trap/EventID 2243 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0008 CPUarg1is disabled.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory CPU = Processor Severity Severity 3 (Informational) Trap/EventID 2243 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE TRUE CPU0010 CPUarg1is throttled.
Detailed Description None. Recommended Response Action Review System Event Log and Operating System Logs. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory CPU = Processor Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message Uncorrectable Machine Check Exception detected on CPU . Contact Support Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory CPU = Processor Severity Severity 3 (Informational) Trap/EventID 2243 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE TRUE CPU0021 CPUarg1is configured correctly.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory CPU = Processor Severity Severity 3 (Informational) Trap/EventID 2243 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE TRUE CPU0025 CPUarg1terminator is absent.
Detailed Description System BIOS was unable to boot the processor. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
CPU0702 Message CPU bus parity error detected. Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action Check system and operating system logs for exceptions. If no exceptions found, remove input power, reinstall the processor, then apply input power. Category System Health SubCategory CPU = Processor Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message CPU bus parity error detected.
CPU0704 CPUarg1machine check error detected. Message Arguments • arg1 = number Detailed Description System event log and OS logs may indicate that the exception is external to the processor. Recommended Response Action 1) Check system and operating system logs for exceptions. If no exceptions are found continue. 2) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 3) Make sure the processor is seated correctly.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0801 CPUarg1voltage regulator module failed. Message Arguments • arg1 = number Detailed Description System performance may be degraded or the system may fail to operate. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0803 The power input for CPUarg1voltage regulator module is lost. Message Arguments • arg1 = number Detailed Description System performance may be degraded or the system may fail to operate.
Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message Power input for CPU voltage regulator module is outside of range. Reseat module Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0805 The power input for CPUarg1voltage regulator module is outside of range, but it is attached to the system.
Category System Health SubCategory CPU = Processor Severity Severity 1 (Critical) Trap/EventID 2241 LCD Message CPU voltage regulator module incorrectly configure. Check configuration Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0816 CPUarg1voltage regulator module is absent.
Recommended Response Action No response action is required. Category System Health SubCategory CPU = Processor Severity Severity 3 (Informational) Trap/EventID 2243 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CPU0819 The power input for CPUarg1voltage regulator module has been restored.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory CPU = Processor Severity Severity 3 (Informational) Trap/EventID 2243 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE CPU9000 Message An OEM diagnostic event occurred.
10 CPUA Event Messages CPUA0023 CPUarg1is absent Message Arguments • arg1 = number Detailed Description None Recommended Response Action Verify processor installation. If present, reseat the processor. Category System Health SubCategory CPUA = Proc Absent Severity Severity 1 (Critical) Trap/EventID 2457 LCD Message CPU is absent. Check CPU Initial Default.
11 CTL Event Messages CTL1 Controller event log:arg1 Message Arguments • arg1 = message Detailed Description This event is retrieved from the controller when iDRAC storage monitoring was not running. Such events which are generated in the past are logged as informational severity. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
Trap/EventID 4331 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE CTL11 Configuration onarg1was reset. Message Arguments • arg1 = controller name Detailed Description A user operation to reset the controller configuration was performed. Recommended Response Action No response action is required.
SubCategory CTL = Storage Contr Severity Severity 1 (Critical) Trap/EventID 4329 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CTL13 Thearg1cache has been discarded. Message Arguments • arg1 = Controller name Detailed Description The controller has flushed the cache and all data in the cache has been lost.
Recommended Response Action Replace the controller, contact Dell technical support at support.dell.com. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) Trap/EventID 4330 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE TRUE CTL16 None of thearg1properties are set.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL2 arg1rebuild rate has changed.
Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL27 Thearg1alarm is silenced.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID 4331 LCD Message No LCD message display defined. Initial Default.
Detailed Description You have enabled the controller alarm. This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description This alert is provided for informational purposes. Recommended Response Action Re-issue the command. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The operation to import foreign configuration (virtual disks, host spares, and so on) completed successfully. Recommended Response Action Verify the foreign configuration was successfully imported by viewing the virtual disks and hot spares. See the hardware documentation for more information. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description A patrol read operation was initiated by the controller or the user. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID 4331 LCD Message No LCD message display defined. Initial Default.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID 4331 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE CTL4 arg1alarm is disabled.
Detailed Description An error involving multiple bits has been encountered during a read or write operation. The error correction algorithm recalculates parity data during read and write operations. If an error involves only a single bit, it may be possible for the error correction algorithm to correct the error and maintain parity data. An error involving multiple bits, however, generally indicates data loss.
CTL42 Enclosure Management Module (EMM) hot plug is not supported onarg1. Message Arguments • arg1 = Controller name Detailed Description An attempt to hot plug an Enclosure Management Module (EMM) has been detected. Recommended Response Action If the new enclosure and its device are not detected by the operating system, try restarting your system to verify the newly attached enclosure and its sub-components are detected. See the hardware documentation for more information.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL44 Diagnostic messagearg1fromarg2 Message Arguments • • arg1 = message arg2 = Controller name Detailed Description A diagnostics test failed. The text for this message is generated by the tool that ran the diagnostics and can vary depending on the situation.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CTL46 Single-bit ECC error. Thearg1DIMM is critically degraded. Message Arguments • arg1 = Controller name Detailed Description The Dual In-line Memory Module (DIMM) is malfunctioning. Data loss or data corruption may occur..
Severity Severity 1 (Critical) Trap/EventID 4329 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CTL48 A foreign configuration was detected onarg1.
Recommended Response Action No response action is required as the controller is taking the required corrective action. However, If this message is generated often (such as during each reboot), then replace the controller. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) Trap/EventID 4330 LCD Message No LCD message display defined. Initial Default.
Detailed Description The NVRAM has corrupt data. The controller is unable to correct the situation. Recommended Response Action Replace the controller. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) Trap/EventID 4330 LCD Message No LCD message display defined. Initial Default.
Arguments • • arg1 = Controller name arg2 = args Detailed Description This alert is provided for informational purposes. The text for this alert is generated by the controller and can vary depending on the situation. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID 4331 LCD Message No LCD message display defined. Initial Default.
Arguments • • arg1 = Controller name arg2 = args Detailed Description This alert is provided for informational purposes. The text for this alert is generated by the controller and can vary depending on the situation. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL56 arg1event log:arg2 Message Arguments • • arg1 = Controller name arg2 = args Detailed Description The text for this alert is generated by the controller and can vary depending on the situation. This text is from events in the controller event log that were generated while Storage Management was not running.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CTL58 arg1SAS SMP communications errorarg2 Message Arguments • • arg1 = Controller name arg2 = args Detailed Description The text for this alert is generated by the firmware and can vary depending on the situation.
Recommended Response Action There may be a problem with the enclosure. Verify the health of the enclosure and its components. To verify the health of the enclosure, select the enclosure object in the tree view. The Health subtab displays a red X or yellow exclamation mark for enclosure components that are failed or degraded. See the enclosure documentation for more information.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • • arg1 = VD names arg2 = Controller name Detailed Description Physical disk(s) have been removed from a virtual disk. The virtual disk will be in Failed state during the next system reboot. This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID 4331 LCD Message No LCD message display defined. Initial Default.
CTL64 Attempted to import Unsupported Virtual Disk type RAIDarg1onarg2. Message Arguments • • arg1 = args arg2 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL66 Attempted to import Unsupported Virtual Disk type RAIDarg1onarg2. Message Arguments • • arg1 = args arg2 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL68 Attempted to import Virtual Disk with missing Physical Disk onarg1. Message Arguments • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL7 Bad block medium error onarg1. Message Arguments • arg1 = Controller name Detailed Description A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL71 Attempted to import an incompatible Physical Disk onarg1. Message Arguments • arg1 = Controller name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID 4330 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CTL73 Foreign configuration is imported only partially. Some configurations failed to import onarg1. Message Arguments • arg1 = Controller name Detailed Description This alert is provided for informational purposes.
SubCategory CTL = Storage Contr Severity Severity 2 (Warning) Trap/EventID 4330 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE CTL75 Preserved cache discarded onarg1. Message Arguments • arg1 = controller name Detailed Description The controller cache was discarded by the user.Data may have been lost or corrupted.
Category Storage SubCategory CTL = Storage Contr Severity Severity 1 (Critical) Trap/EventID 4329 LCD Message No LCD message display defined. Initial Default.
Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL8 Bad block extended sense error onarg1.
Detailed Description A portion of a physical disk is damaged. See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information. Recommended Response Action See Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error for more information. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
CTL201 The current driver versionarg1(arg2) is older than the required driver versionarg3(arg4) forarg5. Message Arguments • • • • • arg1 = major verion number arg2 = minor version number arg3 = major version number arg4 = minor version number arg5 = controller name Detailed Description The controller driver for the identified controller is not a supported version.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL203 Message Abort Check Consistency on Error, Copyback or Auto Copyback on Predictive Failure, and Load Balance values are changed forarg1.
Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = controller name Detailed Description The status of the changed attribute values are reported for information purposes. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
CTL208 Unable to authenticate the entered passphrase for thearg1. Message Arguments • arg1 = controller name Detailed Description Unable to authenticate the entered passphrase. Recommended Response Action Enter the correct passphrase and retry. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL210 Disabled persistent hot spare onarg1. Message Arguments • arg1 = controller name Detailed Description The persistent hot spare feature is disabled on the controller identified in the message. Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL212 The existing encryption key in thearg1is deleted. Message Arguments • arg1 = controller name Detailed Description This alert is generated when the encryption key in the controller is deleted.
SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE CTL214 The Local Key Management (LKM) encryption key in thearg1has changed.
Recommended Response Action Make sure both the cables are securely attached to the enclosure and controller. FOr more information about connecting the cables to the enclosure, see the Cables Attached Correctly section in the PERC Users Guide. Also, make sure both Enclosure Management Modules (EMMs) are healthy. Category Storage SubCategory CTL = Storage Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = controller name Detailed Description The redundant path view on the controller identified in the message is cleared. Recommended Response Action No response action is required. Category Storage SubCategory CTL = Storage Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
12 DH Event Messages DH001 Message Resource needed to perform the operation is unavailable. Detailed Description Resource temporarily unavailable Recommended Response Action Try again. If the error persists, use RACADM command racreset to clear the issue. Category Configuration SubCategory DH = Cert Mgmt Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE DH003 Message Service tag could not be read Detailed Description Service Tag Missing Recommended Response Action Try again. If the error persists, use RACADM command racreset to clear the issue.
DH005 Message CA Cert is corrupted, expired, or does not have signing privileges. Detailed Description Invalid CA Cert Recommended Response Action Close other iDRAC sessions and activities. Try again. Category Configuration SubCategory DH = Cert Mgmt Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description CA priv key/CA Cert mismatch Recommended Response Action Check that the private key parameter is correct. The passphrase can be validated against the private key, passphrase, and certificate can be validated using Openssl tools. Category Configuration SubCategory DH = Cert Mgmt Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory DH = Cert Mgmt Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
13 DIAG Event Messages DIAG0000 Message Pass Detailed Description All Tests passed Recommended Response Action OK, life is good. Category System Health SubCategory DIAG = Diagnostic Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG0115 CPU Stress Thermal condition. Limitarg1C, Actualarg2C. Message Arguments • • arg1 = Degrees arg2 = Degrees Detailed Description Recommended Response Action Check fans. Check for obstructed air vents.
Recommended Response Action MemRX not enabled or not supported. Servers UEFI: Power down system and re-seat DIMMS. Retry test and if no error occurs it was a DIMM connection issue. Client LEGACY: Power down system and re-seat DIMMS. Retry test and if no error occurs it was a DIMM connection issue. Check for latest BIOS. Category System Health SubCategory DIAG = Diagnostic Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
DIAG0125 Message The event log indicates degraded or disabled ECC functionality. Memory testing cannot continue until the problems are corrected, the log cleared and the system rebooted. Detailed Description IPMI System Event Log is full for various reasons or logging has stopped because too many ECC errors have occurred. Recommended Response Action Clear the log and reboot and retest.
DIAG0141 Message Hard Drive - No Hard Drive detected. Detailed Description Recommended Response Action Hard drives are not required on all systems so this message is usually a warning. Desktops and Servers: If the system has a hard disk, power down system and check the signal and power connections to it. Rerun the diagnostic.If no error occurs then it was a cable or connector issue.
Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG0145 Hard Drivearg1- S/Narg2, self test did not complete. Message Arguments • • arg1 = Drive Location arg2 = Serial Number Detailed Description Recommended Response Action Desktops and Servers: Power down the system and check the signal and power connections to the hard drive. Rerun the diagnostic.
Category Storage SubCategory DIAG = Diagnostic Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG0150 Message Hard Drive - No Hard Drive detected, or disk controller not supported.
• • arg3 = 80000000000000?? arg4 = Error Reason Detailed Description Recommended Response Action SMART Predictive Failure indicates the hard drive has failed SMART and maybe nearing the end of its life. Other types of in this category may indicate an intermittent or firmware problem, rerun the test again. Desktops, servers: Check the hard disk drive cables and connections. All systems: If error persists, make sure that hard disk drive firmware and BIOS are current.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG0154 Tape Drivearg1- S/Narg2, incorrect status =arg3\narg4. Message Arguments • • • • arg1 = Drive Location arg2 = Serial Number arg3 = 80000000000000?? arg4 = Error Reason Detailed Description Recommended Response Action Check installation of the tape drive, cables and connections.
LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG0314 Thermal: The (arg1) reading (arg2C) exceeds the thermal limit. Message Arguments • • arg1 = Sensor Name arg2 = Degrees Detailed Description Recommended Response Action Check the event log for thermal events, including defective fans and defective sensors.
Category System Health SubCategory DIAG = Diagnostic Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG0331 Message Video controller - No video controller detected.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG0333 Message Video - User provided no input for graphics test Detailed Description Recommended Response Action No response to a diagnostic prompt and a timeout occurred. Retry the diagnostics.
LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG0415 Cables - Check the following cable, jumper, connection, or sensor:arg1. Message Arguments • arg1 = Name Detailed Description Recommended Response Action Connect the described cable, jumper, sensor, or connection and rerun the diagnostics.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG0512 Fan - The (arg1) fan is running faster than expected. Message Arguments • arg1 = Name Detailed Description Recommended Response Action Re-run the diagnostics; if the problem persists, the fan is faulty.
Detailed Description Recommended Response Action Should not occur Category System Health SubCategory DIAG = Diagnostic Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG8003 Message Fan - Unable to set Manufacturing Mode.
Recommended Response Action Should not occur Category System Health SubCategory DIAG = Diagnostic Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG8005 LCD BIST not supported. or Fan - Fan speed failure. Expected at leastarg1, observedarg2LCD BIST not supported.
DIAG8006 Fan - Unable to set fans toarg1speed. or No chipset event timer! Message Arguments • arg1 = High, Low, or Original Detailed Description Recommended Response Action Should not occur Category System Health SubCategory DIAG = Diagnostic Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG8008 Message Out of memory! fMalloc() Failed!; Unable to allocate memory for object data.; Unable toarg1testable memory.; Unable to start application processor(s); Unable to stop all APs.; The system may be unstable and should be rebooted.
Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG8154 Tape Drivearg1- S/Narg2, ULTRIUMarg3media found but drive requires ULTRIUMarg4forarg5.
Recommended Response Action Use a different tape media. Category Storage SubCategory DIAG = Diagnostic Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG8156 Tape Drivearg1- S/Narg2, no media, cannot test drive.
Arguments • • • arg1 = Tape|Disk arg2 = Drive Location arg3 = Serial Number Detailed Description If then only Dell tape drives are tested and supported. If then disk drive may not be a Dell drive. Recommended Response Action Customer appears to have added a non-Dell Tape drive to his system. Category Storage SubCategory DIAG = Diagnostic Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DIAG8160 PERC Batteryarg1- incorrect status =arg2\narg3. Message Arguments • • • arg1 = PERC Controller Location arg2 = 80000000000000?? arg3 = Error Reason Detailed Description Recommended Response Action "If is (Battery missing or disconnected) then check the battery cable to the PERC controller.
LCD Message No LCD message display defined. Initial Default.
Arguments • • arg1 = decimal arg2 = hex Detailed Description A PCI adapter was detected as present but it does not respond to PCI Configuration Space access, so is very sick or not inserted sungly in the PCI physical slot connector Recommended Response Action Reseat or replace PCI adapter in the PCI slot indicated Category System Health SubCategory DIAG = Diagnostic Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
14 DIS Event Messages DIS001 Message Auto Discovery feature not licensed. Detailed Description Auto Discovery starts automatically, but was unable to find a valid license. Once you have obtained a valid license and installed it, restart. Recommended Response Action Follow service providers instructions to enable the license. Category Configuration SubCategory DIS = Auto-Discovery Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE DIS003 Message Auto Discovery process started. Detailed Description Auto Discovery process will try to connect to a Provisioning Server over the next 24 hours. Recommended Response Action No response action is required.
DIS005 Auto Discovery communicated successfully with Provisioning Serverarg1. Message Arguments • arg1 = provisioning server name Detailed Description Message was sent successfully from Auto Discovery to Provisioning Server to request certificate. Recommended Response Action No response action is required. Category Configuration SubCategory DIS = Auto-Discovery Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
DIS007 Message Unable to notify Provisioning Server of iDRAC IP address change. Detailed Description Unable to connect to Provisioning Server to notify about new iDRAC IP . Recommended Response Action Check Provisioning Server connectivity and retry.. Category Configuration SubCategory DIS = Auto-Discovery Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
DIS009 Notification of iDRAC IP address changed toarg1sent to Provisioning Server. Message Arguments • arg1 = new IP address Detailed Description iDRAC IP address sent to Provisioning Server. Recommended Response Action No response action is required. Category Configuration SubCategory DIS = Auto-Discovery Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE DIS011 Message Auto Discovery client using customer signed client certificate. Detailed Description Customer provided client certificate is being used. Auto Discovery client is using this certificate for the SSL connection with the Provisioning Server.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE DIS013 Message Auto Discovery client using default client certificate. Detailed Description Default client certificate is being used. Auto Discovery client is using this certificate for the SSL connection with the Provisioning Server. Recommended Response Action No response action is required.
DIS015 Message Auto Discovery client using default CA certificate to authenticate Provisioning Server. Detailed Description Auto Discovery client is using the default Certificate Authority certificate to authenticate the Provisioning Server for the SSL connection.. Recommended Response Action No response action is required. Category Configuration SubCategory DIS = Auto-Discovery Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
15 DKM Event Messages DKM1000 Message A network problem detected. Cannot contact key management server. Detailed Description None Recommended Response Action Check for network connectivity. Review network, server, and client configuration. Category System Health SubCategory DKM = Dell Key Mngr Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DKM1002 Message Key management server certificate problem detected. Detailed Description None Recommended Response Action Check server configuration and certificates Category System Health SubCategory DKM = Dell Key Mngr Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
DKM1006 Message Key management server error detected. Detailed Description None Recommended Response Action Review server error logs for additional information. Category System Health SubCategory DKM = Dell Key Mngr Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message Key management server error. Check configuration Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DKM0002 arg1key add failed for slotarg2of userarg3, due toarg4. Message Arguments • • • • arg1 = Security_Key arg2 = Slot_num arg3 = Username arg4 = error_msg Detailed Description %s key add failed for slot %d of user %d, due to %s. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE DKM0004 DKM Error Codearg1:arg2error. Message Arguments • • arg1 = Error_code_name arg2 = Error_code_msg Detailed Description DKM Error Code %d: %s error.
16 ENC Event Messages ENC1 arg1was inserted. Message Arguments • arg1 = Enclosure Management Module Name Detailed Description An Enclosure Management Module (EMM) has failed is inserted into the enclosure. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) Trap/EventID 4339 LCD Message No LCD message display defined. Initial Default.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE ENC11 Thearg1service tag was changed. Message Arguments • arg1 = Enclosure Name Detailed Description An enclosure service tag was changed. In most circumstances, this service tag should only be changed by Dell support.
Severity Severity 3 (Informational) Trap/EventID 4339 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE ENC13 Unsupported configuration detected onarg1.arg2arg3 Message Arguments • • • arg1 = Enclosure Name arg2 = EMM0 1 arg3 = EMM1 2 Detailed Description An unsupported configuration was detected.
Recommended Response Action Remove the extra enclosures. Refer to the storage hardware documentation for maximum number of enclosures that can be connected. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 1 (Critical) Trap/EventID 4337 LCD Message No LCD message display defined. Initial Default.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The controller has lost communication with an Enclosure Management Module (EMM). The cables may be loose or defective. Recommended Response Action Make sure the cables are attached securely. See the storage hardware documentation for more information on checking the cables. Reboot the system. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 1 (Critical) Trap/EventID 4337 LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = Enclosure Management Module Name Detailed Description An Enclosure Management Module (EMM) was removed. Recommended Response Action Reinsert the Enclosure Management Module (EMM). See the storage hardware documentation for information on replacing the EMM. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 1 (Critical) Trap/EventID 4337 LCD Message No LCD message display defined. Initial Default.
ENC22 Thearg1has a bad sensorarg2. Message Arguments • • arg1 = Enclosure Name arg2 = args Detailed Description The enclosure has a bad sensor. The enclosure sensors monitor the fan speeds, temperature probes, and so on. Recommended Response Action Refer to the storage hardware documentation for more information. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 2 (Warning) Trap/EventID 4338 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE ENC24 Communication witharg1is intermittent. Message Arguments • arg1 = enclosure name Detailed Description The controller is not receiving a consistent response from the enclosure.There could be a firmware problem or an invalid cabling configuration.If the cables are too long, they degrade the signal.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE ENC26 arg1is not responding. Message Arguments • arg1 = enclosure name Detailed Description The enclosure or an enclosure component is in a Failed or Degraded state.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE ENC28 Enclosure Management Module (EMM) firmware version mismatch detected inarg1.arg2arg3.
Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) Trap/EventID 4339 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE ENC3 arg1is shutdown.
Arguments • arg1 = Enclosure Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
ENC32 Storage Enclosure Processor (SEP) forarg1has been rebooted. Message Arguments • arg1 = Enclosure Name Detailed Description The SEP has been rebooted as part of the firmware download operation and will be unavailable until the operation completes. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE ENC4 arg1firmware mismatch. Message Arguments • arg1 = Enclosure Name Detailed Description The firmware on the EMM modules is not the same version. It is required that both modules have the same version of the firmware.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE ENC5 Redundancy onarg1is degraded Message Arguments • arg1 = Enclosure Name Detailed Description One or more of the enclosure components has failed. For example, a fan or power supply may have failed.
Recommended Response Action Check for problems with the cables. See the Cables attached correctly section for more information on checking the cables. You should also check to see if the enclosure has degraded or failed components. To do this, select the enclosure object in the tree view and click the Health subtab. The Health subtab displays the status of the enclosure components.
ENC8 Thearg1alarm was disabled. Message Arguments • arg1 = Enclosure Name Detailed Description You have disabled the enclosure alarm. Recommended Response Action No response action is required. Category Storage SubCategory ENC = Storage Enclosr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE ENC100 arg1is sending inconsistent reponses to the controller. Message Arguments • arg1 = enclosure name Detailed Description The storage controller is not receiving a consistent response from the enclosure due to a firmware problem or an incorrect cabling configuration.
17 FAN Event Messages FAN1000 arg1was removed. Message Arguments • arg1 = Fan Sensor Name Detailed Description The enclosure detected that a fan was removed and the enclosure is no longer functioning in optimal condition.. Recommended Response Action Re-insert the fan into the enclosure. Contact technical support if the issue persists. Category Storage SubCategory FAN = Fan Event Severity Severity 1 (Critical) Trap/EventID 4201 LCD Message No LCD message display defined. Initial Default.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FAN1002 arg1has failed. Message Arguments • arg1 = Fan Sensor Name Detailed Description The enclosure detected that a fan has failed and the enclosure is no longer functioning in optimal condition..
SubCategory FAN = Fan Event Severity Severity 2 (Warning) Trap/EventID 2154 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE FAN0001 Fanarg1RPM is less than the lower critical threshold. Message Arguments • arg1 = number Detailed Description The fan is not performing optimally.
Category System Health SubCategory FAN = Fan Event Severity Severity 2 (Warning) Trap/EventID 2154 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE FAN0003 Fanarg1RPM is greater than the upper critical threshold. Message Arguments • arg1 = number Detailed Description The fan is not performing optimally.
Recommended Response Action Remove and re-install the fan. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory FAN = Fan Event Severity Severity 1 (Critical) Trap/EventID 2153 LCD Message Fan RPM is outside of range. Check fan. Initial Default.
Detailed Description The fan may be required for optimal performance. Recommended Response Action If unintentional, install a fan. Category System Health SubCategory FAN = Fan Event Severity Severity 1 (Critical) Trap/EventID 2153 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE FAN0007 Fanarg1was inserted.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory FAN = Fan Event Severity Severity 3 (Informational) Trap/EventID 2155 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE FAN0009 Fanarg1is absent.
Detailed Description The fan may be required for optimal performance. Recommended Response Action No response action is required. Category System Health SubCategory FAN = Fan Event Severity Severity 2 (Warning) Trap/EventID 2154 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE FAN0011 Fanarg1is enabled.
Detailed Description The fan identified in the message has failed or it is not installed correctly. Recommended Response Action Remove and re-install the fan or replace the fan, and open the OMSA Web interface to verify if the fan specified in the message is displayed correctly. If the issue persists, contact your service provider. Category System Health SubCategory FAN = Fan Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
FAN0022 Thearg1sensor has failed, and the last recorded value by the sensor wasarg2RPM. Message Arguments • • arg1 = sensor name arg2 = fan speed Detailed Description The sensor identified in the message has failed. The sensor may be required for optimal system performance. Recommended Response Action Check the Embedded System Management (ESM) Log for any sensor related faults. If the fan sensor has failed, replace the system board. For more information, contact your service provider.
Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FAN0024 Thearg1sensor returned to a normal state with a value ofarg2RPM. Message Arguments • • arg1 = sensor name arg2 = fan speed Detailed Description The sensor identified in the message has returned to a normal state. Recommended Response Action No response action is required.
SubCategory FAN = Fan Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FAN0026 Thearg1sensor detected an error with a value ofarg2RPM.
Detailed Description The sensor identified in the message has failed. The sensor may be required for optimal system performance. Recommended Response Action Check the Embedded System Management (ESM) Log for any sensor related faults.If the fan sensor has failed, replace the system board. For more information, contact your service provider. Category System Health SubCategory FAN = Fan Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined.
18 FC Event Messages FC102 The FCarg1Portarg2link is down Message Arguments • • arg1 = Controller arg2 = Port Detailed Description The FC link is down. Either the FC cable is not connected or the FC device is not working. Recommended Response Action Verify that the FC port is enabled and if the port has Activity/Speed LEDs, that they are lit. Check the FC cable, FC cable connections, and the attached FC switch.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE FC001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FC003 Message Missing required parameter. Detailed Description An invalid number of arguments was sent to the method.d. Recommended Response Action Enter required input parameters and retry. For more information, see Lifecycle Controller Users Guide or the FC HBA Profile specification..
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FC005 Message The number of AttributeName array elements does not match the AttributeValue array element count. Detailed Description The number of AttributeName and AttributeValue array elements are not equal. Recommended Response Action Provide equal number of array elements for AttributeName and AttributeValue parameters.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FC007 Message Configuration job already created, cannot create another config job on specified target until existing job is completed or is cancelled. Detailed Description Configuration job already created on the specified target. No further command is allowed until the existing job succeeded or the job is cancelled.
FC009 Message Lifecycle Controller is currently in use. Detailed Description Lifecycle Controller cannot gain access to internal storage due to use by another application or operation. Recommended Response Action Wait for Lifecycle Controller to complete the current operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FC011 Message Configuration job already created, pending data cannot be deleted Detailed Description Configuration job already created on the specified target. No further command is allowed until the existing job is completed Recommended Response Action Cancel the configuration job or wait for the job to complete.
FC013 Invalid AttributeName:arg1. Message Arguments • arg1 = parameter name Detailed Description An incorrect AttributeName parameter name was provided. Recommended Response Action Enter the correct AttributeName available for the component in the system. Identify the correct AttributeName from the attribute enumeration response for the component or refer to the FC HBA Profile specification.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FC015 Unable to change read-only attributearg1. Message Arguments • arg1 = parameter name Detailed Description A set attribute operation was not successful because the attribute is read-only. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FC017 Message Unable to perform the operation due to an internal error in iDRAC. Detailed Description An internal error occurred in iDRAC and the operation cannot continue. An iDRAC reset is required to recover from the error.
19 FSD Event Messages FSD000 Debug authorized by customer; debugcaps:arg1, was authorized by:arg2, atarg3for the period:arg4toarg5. Message Arguments • • • • • arg1 = DebugCaps arg2 = iDRAC User arg3 = unblock time arg4 = start time arg5 = end time Detailed Description The customer has authorized the specified debug capabilities on this iDRAC. (This should occur in response to a request from Dell tech support.
• arg5 = end time Detailed Description Dell has authorized the specified debug capabilities. Each debug capability represents a certain action Dell engineers can perform to debug iDRAC. Recommended Response Action No response action is required. Category Audit SubCategory FSD = Debug Severity Severity 3 (Informational) Trap/EventID 8595 LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default.
20 HWC Event Messages HWC1000 Thearg1is present. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default.
Trap/EventID 2329 LCD Message The is absent. Check hardware Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE HWC1002 Thearg1is disabled. Message Arguments • arg1 = name Detailed Description None Recommended Response Action If device disabled unexpectedly, re-enable device.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE HWC1004 Message The storage adapter is present. Detailed Description None Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC1006 Message The storage adapter is disabled. Detailed Description None Recommended Response Action If adapter disabled unexpectedly, re-enable the storage adapter.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE HWC1008 Message The backplane is present. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default.
HWC1010 Message The backplane is disabled. Detailed Description None Recommended Response Action If disabled unexpectedly, re-enable backplane. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC1013 Message The USB cable is absent.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC1015 The mezzanine cardarg1is absent.
• arg2 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC1101 Thearg1is removed from slotarg2.
HWC2000 Thearg1cable or interconnect is connected. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE HWC2002 The storagearg1cable or interconnect is connected. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE HWC2004 The system boardarg1cable or interconnect is connected. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required.
LCD Message System board cable or interconnect failure. Check connection Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC2006 Thearg1is not installed correctly. Message Arguments • arg1 = name Detailed Description The device may be necessary for proper operation. System functionality may be degraded.
Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC2008 A fabric mismatch detected for mezzanine cardarg1. Message Arguments • arg1 = number Detailed Description The fabric type for the IOM and mezzanine cards must match.
SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE HWC2010 Message The riser board cable or interconnect is connected. Detailed Description None Recommended Response Action No response action is required.
LCD Message Riser board cable or interconnect failure. Check connection Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC2012 A fabric mismatch detected on fabricarg1with server in slotarg2. Message Arguments • • arg1 = name arg2 = number Detailed Description The fabric type on the server does not matach that of the IO module.
Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC2014 A hardware misconfiguration detected onarg1. Message Arguments • arg1 = name Detailed Description None. Recommended Response Action Make sure the hardware is installed correctly.
SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC3000 Thearg1is removed. Message Arguments • arg1 = name Detailed Description The removed device may be necessary for proper operation. System functionality may be degraded.
Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE HWC3002 Serverarg1is removed.
Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC3004 IO modulearg1is removed.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC4002 Message A hardware incompatibility detected between BMC/iDRAC firmware and other hardware.
Trap/EventID 2331 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE HWC4010 Hardware successfully updated for mezzanine cardarg1. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 2329 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE HWC4012 Message Hardware successfully updated for embedded NIC. Detailed Description None Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE HWC4014 Message Link Tuning data successfully updated. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID 2331 LCD Message No LCD message display defined.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE HWC4016 Hardware incompatibility detected with mezzanine cardarg1. Message Arguments • arg1 = number Detailed Description The system has detected a mezzanine card that is not supported on this system. Recommended Response Action 1) Review system documentation for supported mezzanine cards.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC5001 arg1is offline. Message Arguments • arg1 = name Detailed Description None Recommended Response Action If unexpected, check presence, then re-install or reconnect.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC5003 arg1is operating correctly. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC5006 A failure is detected onarg1. Message Arguments • arg1 = name Detailed Description None Recommended Response Action Contact technical support.
SubCategory HWC = Hardware Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC5010 arg1cannot detect any hosts. Message Arguments • arg1 = name Detailed Description None Recommended Response Action Contact technical support.
Category System Health SubCategory HWC = Hardware Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC5014 arg1is not functional and is powered off.
Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC5031 IO modulearg1is offline.
Detailed Description The fabric type for IOMs on the same chassis fabric must match. Recommended Response Action Check chassis fabric type in CMC GUI and compare to the type of both IOMs. Category System Health SubCategory HWC = Hardware Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Link tuning table not supported for this IO modular. Recommended Response Action Update the CMC firmware. If the problem persists, contact support. Category System Health SubCategory HWC = Hardware Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = number Detailed Description The IOM module performance may be impact. Recommended Response Action Contact technical support. Refer to your product documentation to choose the contact method that is convenient for you. Category System Health SubCategory HWC = Hardware Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
HWC6000 Thearg1controller is offline. Message Arguments • arg1 = name Detailed Description Information and status from the controller is unavailable. Recommended Response Action Remove and reapply input power. If problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory HWC = Hardware Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC6002 Thearg1controller is stuck in boot mode. Message Arguments • arg1 = name Detailed Description Information and status from the controller is unavailable. Recommended Response Action Remove and reapply input power. If problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC6004 Cannot communicate witharg1controller. Message Arguments • arg1 = name Detailed Description Information and status from the controller is unavailable. Recommended Response Action Remove and reapply input power. If problem persists, contact technical support.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC7000 Serverarg1health changed to a normal state. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC7004 Serverarg1health changed to a critical state from either a normal or warning state. Message Arguments • arg1 = number Detailed Description Server health changed to a critical state from either a normal or warning state.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC7008 Serverarg1health changed to a warning state from more severe state. Message Arguments • arg1 = number Detailed Description Server health changed to a warning state from more severe state.
SubCategory HWC = Hardware Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC7012 Serverarg1health changed to a non-recoverable state. Message Arguments • arg1 = number Detailed Description Server health changed to a non-recoverable state.
Recommended Response Action No response action is required. Category Audit SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC8001 A device was added to the system at this location:arg1. Additional Details:arg2.
Arguments • • arg1 = device location arg2 = details Detailed Description A device was was removed from the system at the location identified in the message. Along with the device location, additional event details are provided if available. Recommended Response Action No response action is required. Category Audit SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC8004 The SD card device sensor has failed. SD card location:arg1, SD card device type:arg2, SD card state:arg3. Message Arguments • • • arg1 = location arg2 = type arg3 = state Detailed Description The SD card device sensor of the type identified in the messaage has failed. The current status of the SD card is also displayed.
Recommended Response Action No response action is required. Category System Health SubCategory HWC = Hardware Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC8006 The SD card device state has changed to a warning state.
HWC8007 The SD card has failed. SD card location:arg1, SD card device type:arg2, SD card state:arg3. Message Arguments • • • arg1 = location arg2 = type arg3 = state Detailed Description The SD card sensor detected an SD card failure. Recommended Response Action Replace the old SD card with a new SD card. Category System Health SubCategory HWC = Hardware Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE HWC8009 SD card device sensor value unknown. SD card location:arg1, SD card device type:arg2, SD card state:arg3.
SubCategory HWC = Hardware Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE HWC0002 Message Unable to detect vFlash SD card. Detailed Description The vFlash SD Card is either not present or not correctly inserted.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE HWC0004 Message Unable to initialize vFlash SD card. Detailed Description The vFlash SD card is incorrectly inserted, the vFlash SD card is faulty, or there is an iDRAC communication failure.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE HWC0006 Message Unable to save vFlash SD card settings. Detailed Description If a vFlash SD card is not present in the system or if the card is locked, Lifecycle Controller cannot save the settings. Recommended Response Action Insert the vFlash SD card or unlock the vFlash SD card and retry the operation.
HWC0008 Message Unable to communicate with iDRAC. Detailed Description An internal error occurred while communicating with iDRAC. Recommended Response Action Exit the wizard and retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation.
HWC0010 Message Invalid folder name or USB drive not found. Detailed Description Operation failed because the folder name entered is incorrect or the USB drive is disconnected. Recommended Response Action Enter a valid folder name or attach the USB drive and retry the operation. Category Configuration SubCategory HWC = Hardware Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The USB drive is write protected. Recommended Response Action Remove write protection on the USB drive before retrying the operation. Category Configuration SubCategory HWC = Hardware Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory HWC = Hardware Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE HWC0015 Message iDRAC not responding. Detailed Description iDRAC has encountered a hardware error. Recommended Response Action Retry the operation.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
21 IPA Event Messages IPA0001 Message Invalid NIC IP address parameter specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Enter the valid IP Address. Category Audit SubCategory IPA = DRAC IP Address Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE IPA0003 Message Invalid subnet mask specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Enter the appropriate subnet mask. Category Audit SubCategory IPA = DRAC IP Address Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
IPA0100 iDRAC IP Address changed fromarg1toarg2 Message Arguments • • arg1 = Old IP Address arg2 = New IP Address Detailed Description iDRAC IP address. This notification will be generated when the iDRAC network card selection is changed, if the DHCP lease expires and the DHCP server assigns another address, or if iDRAC IP address is manually changed.
22 JCP Event Messages JCP001 Message Task successfully scheduled. Detailed Description The UEFI automated task related to the job was successfully scheduled. Recommended Response Action No response action is required. Category Configuration SubCategory JCP = Job Control Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE JCP003 Message Job failed. Detailed Description An iDRAC reboot caused a failure of the scheduled jobs. Recommended Response Action Retry the update and schedule the update job. Category Configuration SubCategory JCP = Job Control Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined.
JCP005 Message System services cancelled - Job Failed Detailed Description System services was cancelled by selecting CTRL+E on boot up and cancelling it through the iDRAC configuration utility. This prevents jobs from executing further. Recommended Response Action Enable system services through the CTRL+E on boot up on the target system through the iDRAC configuration utility.
Detailed Description The submitted job completed successfully. Recommended Response Action No response action is required. Category Configuration SubCategory JCP = Job Control Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action If the job was not cancelled manually, then Lifecycle Controller may be in Recovery mode. To verify or change Recovery mode, use F2 Setup to select iDRAC Configuration then Lifecycle Controller Settings. Category Configuration SubCategory JCP = Job Control Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Wait for the running job to complete and theen rety the operation. Category Configuration SubCategory JCP = Job Control Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SubCategory JCP = Job Control Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE JCP028 Message Job status updated.
23 LC Event Messages LC001 Message Command successful. Detailed Description The command completed successfully. Recommended Response Action No response action is required. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC003 Message Failed to change the firmware update mode. Detailed Description An error occurred while trying to set the firmware update mode. Recommended Response Action Verify that the firmware version supports this mode. Also confirm that the command and parameters are correct.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC005 Message Invalid firmware update mode. Detailed Description The value provided for the update mode parameter is invalid. Recommended Response Action Verify that the correct firmware update mode was entered.
LC007 Message Invalid Parameter. Detailed Description One of the parameters specified in the method is invalid. Recommended Response Action Verify that the parameters specified are correct. For a list of parameters for this method refer to the Lifecycle Controller User Guide. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description There were insufficient parameters specified for this command. Recommended Response Action Confirm that the parameters provided are correct. For a list of parameters for this method refer to the Lifecycle Controller User Guide. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC012 Message Another process is using Lifecycle Controller. Detailed Description Lifecycle Controller is in use by another process.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC014 Message Maximum comment length is 255 characters. Detailed Description Maximum comment length is 255 characters. Recommended Response Action Limit the number of characters in the comment to 255 characters.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC016 Missing required parameter,arg1. Message Arguments • arg1 = parameter Detailed Description A required method argument was missing. Recommended Response Action Include all the parameters required for the command. Check Lifecycle Controller Profile documentation and try again.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC018 Message Server certificate successfully modified. iDRAC will now restart and be unavailable during restart. Detailed Description The command was successful. Communication to iDRAC will be lost as iDRAC restarts to use the new server certificate.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC020 Message PKCS12 decrypt of the certificate could not complete. Detailed Description The contents of the PKCS12 parameter was not valid because: 1) not a valid PKCS12 file 2) not a valid pfx file 3) did not contain a certificate that matched the private key in the file.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC022 Message Lifecycle Controller Log Export was successful. Detailed Description The Lifecycle Controller Log was successfully exported to the destination specified. Recommended Response Action No response action is required.
LC024 Message Unable to retrieve Lifecycle Controller Log records. Detailed Description Unable to retrieve Lifecycle Controller Log records due to an internal error. Recommended Response Action Try one of the following: 1) Try the operation again 2) AC power cycle system 3) apply the latest firmware update packages for Lifecycle Controller and iDRAC.
Detailed Description This method is not supported in this version of the iDRAC firmware. Recommended Response Action Update the iDRAC firmware to a version that supports the log export. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC029 Message Invalid file path specified. Detailed Description An invalid File Path was specified in the export operation.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC031 Message Internal error occurred while exporting inventory. Detailed Description An internal error occured while exporting the Hardware Inventory XML file. Recommended Response Action Reset iDRAC and retry the command.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC033 Message As-Shipped Hardware Inventory export was successful. Detailed Description The Hardware Inventory XML file representing the system configuration as shipped from the factory was successful. Recommended Response Action No response action is required.
LC035 Message As-Shipped Hardware Inventory Export method is not supported. Detailed Description This method is not supported in this version of Firmware. Recommended Response Action Update the iDRAC Firmware to a version that supports this method. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Lifecycle Controller is locked by another instance of Lifecycle ControllerLog Export operation. Wait for that operation to complete before attempting to run another command. Recommended Response Action Try one for the following: 1) Wait approximately 2 minutes and retry the operation. 2) Reset iDRAC and retry the operation. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined.
Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC040 Message Memory resource allocation failure. Detailed Description Unable to allocate required memory to perform the operation.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC044 Message An instance of Lifecycle Controller system configuration wipe is already running. Detailed Description The Lifecycle Controller system configuration wipe operation is currently running. The operation deletes user information from system hardware and resets BIOS, iDRAC and Lifecycle Controller to default settings.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC046 Message An instance of DownloadServerPublicKey is already running. Detailed Description The DownloadServerPublicKey operation is in progress. The operation may take a few minutes to complete before the operation can be attempted again. Recommended Response Action Wait a few minutes before retrying retry the operation.
LC048 Message Invalid input value for IPChangeNotifyPS. Detailed Description The value provided to set the attribute is invalid.. Recommended Response Action For more information on the valid values, see Lifecycle Controller-Remote Services documentation. Retry the operation with a valid value for the IPChangeNotifyPS attribute. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
LC050 Message Invalid value for SystemServicesState. Detailed Description The value provided to set the attribute is invalid.. Recommended Response Action For more information on the valid values, see Lifecycle Controller-Remote Services documentation. Retry the operation with a valid value for the SystemServicesState attribute. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description There can only be one Server Profile Import job at a time. Recommended Response Action Wait for the existing Server Profile Import job to run and complete or cancel it, before retrying the operation. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC055 Message Operation failed due to invalid attribute array.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC057 Message Invalid AttributeName parameter value. Detailed Description The attribute name provided is not valid for the current method. Recommended Response Action Retry the operation with a valid AttributeName parameter value.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC059 Cannot set read only attribute specified in AttributeNamearg1. Message Arguments • arg1 = parameter Detailed Description The attribute specified is read only and the value cannot be changed. Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC0101 Message Lifecycle Controller action was cancelled by a user. Detailed Description A user cancelled Lifecycle Controller actions. Any remote jobs pending execution were cancelled. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LC061 Message Lifecycle controller is ready to take provisioning requests Detailed Description Jobs, invoke methods, enumerates can now be performed on Lifecycle controller. Lifecycle controller is ready to take provisioning requests. Recommended Response Action No response action is required.
LC063 Message Cannot create new jobs until the existing running jobs are completed or deleted. Detailed Description All jobs must be completed before creating a new job. Recommended Response Action Retry after all the existing jobs are completed or deleted. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
LC065 Message The iDRAC static IP address information is not fully configured. The missing attribute InstanceID isarg1. Arguments • arg1 = attribute key Detailed Description The static IPv4 information for the iDRAC represented by the related iDRACCard Attributes must be configured correctly. Recommended Response Action Configure the iDRAC static IP address information by setting the related iDRACCard Attributes.
LC067 Message Successfully exported SSL Certificate. Detailed Description The Export Certification operation successfully exported the SSL Certificate. Recommended Response Action No response action is required. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
LC069 Message Certificate does not exist. Detailed Description The certificate does not exist for export or delete operation. Recommended Response Action No response action is required. Category Configuration SubCategory LC = Lifecycle Contr Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Unable to export or import server configuration XML because the Lifecycle Controller version on the target does not support this feature. Recommended Response Action Update the Lifecycle Controller version on the target system to a version that supports the export and import server configuration XML feature, and retry the operation.
24 LIC Event Messages LIC000 Message The License Manager action succeeded. Detailed Description This command was successful. Recommended Response Action No response action is required. Category Audit SubCategory LIC = Licensing Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LIC002 Message License Manager is unable to allocate the required resources at startup. Detailed Description The error may occur when License Manager: 1) Is unable to allocate system resources. 2) Determines one or more files is incompatible with the current firmware version.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LIC004 Message An internal system error has occurred. Detailed Description This error condition is reported when one of the following conditions occur: 1) Operating system detected a file error (for example, bad CRC, bad sector) when reading/writing a license manager file. The error could indicate bad or corrupt FLASH device.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LIC006 Message The license has expired. Detailed Description The license end date has been reached. Recommended Response Action Obtain a replacement license and import it. Category Audit SubCategory LIC = Licensing Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LIC008 Message The license binding ID does not match the device unique identifier. Detailed Description All bound perpetual licenses contain the unique identifier of a specific device. The unique identifier binds a license to the device. For example, iDRACs unique identifier is the service tag.
LIC010 Message Import failed: This license is not for the specified device. Detailed Description A license is not imported to the iDRAC when one of the following conditions exists: 1) The license is not for the iDRAC. 2) The target system may not be upgraded to the product class specified by the license (for example, user may not upgrade from an express product class to an enterprise product class).
LIC012 Message The license file does not exist. Detailed Description This error may occur if: 1) The license was deleted by another user. 2) The license that is being imported may have been deleted from the temporary storage before the import operation completed. 3) At start-up, License Manager does not find the license assigned to the device. This may occur if a power outage occurs before a license delete operation completes. Recommended Response Action Re-import the license.
LIC014 Message Multiple backup or restore operations have been simultaneously attempted on the License Manager database. Detailed Description An attempt to lock the License Manager database for Lifecycle Controller backup or restore occurred when the License Manager database was already locked. This may occur when two or more users attempt to do a backup or restore operation simultaneously. Recommended Response Action Repeat the Lifecycle Controller backup or restore operation.
LIC016 Message The feature dependencies of the license are not met. Detailed Description The license includes features that are dependent upon additional licensed features not included in this license. These licensed features are not activated until license(s) with the dependent licensed features are imported to the system. Recommended Response Action Import the license(s) that meet the license features dependencies.
LIC018 Message The license is already imported. Detailed Description The license is already imported on the system and does not need to be reimported. Recommended Response Action No response action is required. Category Audit SubCategory LIC = Licensing Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Importing an upgrade license without a base license is not allowed, as it may be a violation of the license EULA agreement. If the base license was deleted, the system allows the user to override the warning by invoking the import override option. Recommended Response Action If the base license was deleted, override the warning by invoking the import override option.
• arg3 = number of days Detailed Description This license is going to expire. An expired license could result in the loss of functionality that is specific to the features supported by the license. Recommended Response Action Purchase a new license to prevent interruption of licensed features. Category Audit SubCategory LIC = Licensing Severity Severity 2 (Warning) Trap/EventID 8514 LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = entitlement ID Detailed Description Signature verification failed due to an error in the saved license file. Recommended Response Action Delete and re-import the license file. Category Audit SubCategory LIC = Licensing Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The License Manager sets a maximum time period that its database may be locked. If that timeout exceeds, it releases the lock conditions and reports the error. The user must assume that the Lifecycle Controller backup or restore operation failed and should repeat the operation. Recommended Response Action Repeat the backup or restore operation.
Arguments • • arg1 = entitlement ID arg2 = device name Detailed Description The license has expired. This could result in the loss of functionality that is specific to the features supported by the license. Recommended Response Action Obtain and import a replacement license. Category Audit SubCategory LIC = Licensing Severity Severity 2 (Warning) Trap/EventID 8513 LCD Message No LCD message display defined. Initial Default.
LIC209 Licensearg1exported from devicearg2successfully. Message Arguments • • arg1 = entitlement ID arg2 = device name Detailed Description A license was successfully exported. Recommended Response Action No response action is required. Category Audit SubCategory LIC = Licensing Severity Severity 3 (Informational) Trap/EventID 8515 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE LIC211 Message The iDRAC feature set has changed. Detailed Description License import/delete/expiration resulted in a feature set change. Recommended Response Action No response action is required. Category Audit SubCategory LIC = Licensing Severity Severity 3 (Informational) Trap/EventID 8515 LCD Message No LCD message display defined.
25 LNK Event Messages LNK2700 Thearg1LAN heartbeat is lost. Message Arguments • arg1 = name Detailed Description CMC has lost network connection. Recommended Response Action Check network cable and network connections. Category System Health SubCategory LNK = Link Status Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LNK0001 Message Network share name unavailable. Detailed Description The entered network share name is not valid. Recommended Response Action Enter a valid network share name and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE LNK0003 Message DNS unreachable. Detailed Description DNS query failed due to an incorrect host name or DNS server issue. Recommended Response Action Enter the correct host name or ressolve the DNS server issue and retry the operation.
LNK0005 Message Unable to connect to DHCP server. Detailed Description Error occurred while communicating with the DHCP server because the network settings are not configured correctly or the DHCP server could not be contacted. Recommended Response Action Verify if the network cable is connected and network configuration settings are correct, and retry the operation. If the problem persists, update the network interface controller (NIC) firmware to the latest version and retry the operation.
26 LOG Event Messages LOG320 Log monitoring is disabled. Log type:arg1. Message Arguments • arg1 = log type Detailed Description The hardware log in the system is disabled. The log type information is provided. Recommended Response Action No response action is required. Category Audit SubCategory LOG = Log event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LOG322 The log size is no longer near the maximum capacity. Log type:arg1. Message Arguments • arg1 = log type Detailed Description The hardware log in the system is no longer near its maximum capacity.
Category System Health SubCategory LOG = Log event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LOG324 The log size has reached its maximum capacity. Log type:arg1.
Detailed Description Unable to receive any log entries, and therefore log status cannot be monitored. The log type information is provided. Recommended Response Action Make sure that iDRAC is functioning correctly. Category System Health SubCategory LOG = Log event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action No response action is required. Category Audit SubCategory LOG = Log event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LOG201 Message Recovered from LC Log corruption.
SubCategory LOG = Log event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE LOG007 The previous log entry was repeatedarg1times.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
27 MEM Event Messages MEM0000 Persistent correctable memory errors detected on a memory device at location(s)arg1. Message Arguments • arg1 = location Detailed Description The memory is operational. This is an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Trap/EventID 2265 LCD Message Multi-bit memory error on . Reseat memory Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM0002 Parity memory errors detected on a memory device at locationarg1. Message Arguments • arg1 = location Detailed Description The memory is operational. This is an early indicator of a possible future uncorrectable error.
Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM0004 Memory device at locationarg1is disabled. Message Arguments • arg1 = location Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Persistent correctable memory error limit reached for . Reseat memory. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE MEM0006 Memory device at locationarg1is present.
Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Unsupported memory configuration. Check memory . Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE MEM0008 Memory device at locationarg1is spare memory.
Recommended Response Action If unexpected, review system logs for power or thermal exceptions. Category System Health SubCategory MEM = Memory Severity Severity 2 (Warning) Trap/EventID 2266 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM0010 Memory device at locationarg1is over heating.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE MEM0020 Memory device at locationarg1is enabled.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM0022 Memory device at locationarg1is absent.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE MEM0600 Memory device was added at locationarg1.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = location Detailed Description The memory may not be operational. This an early indicator of a possible future uncorrectable error. Recommended Response Action Re-install the memory component. If the problem continues, contact support. Category System Health SubCategory MEM = Memory Severity Severity 2 (Warning) Trap/EventID 2266 LCD Message No LCD message display defined. Initial Default.
MEM1000 Memory device at locationarg1transition to a running state. Message Arguments • arg1 = location Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE MEM1002 Memory device at locationarg1is in test. Message Arguments • arg1 = location Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE MEM1004 Memory device at locationarg1is powered off. Message Arguments • arg1 = location Detailed Description None Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE MEM1006 Memory device at locationarg1is online. Message Arguments • arg1 = location Detailed Description None Recommended Response Action No response action is required.
Trap/EventID 2265 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE MEM1008 Memory device at locationarg1is offline. Message Arguments • arg1 = location Detailed Description None Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE MEM1010 Memory device at locationarg1is off-duty. Message Arguments • arg1 = location Detailed Description None Recommended Response Action No response action is required.
SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM1012 Memory device at locationarg1is in a degraded state. Message Arguments • arg1 = location Detailed Description None Recommended Response Action Re-install the memory component.
Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE MEM1014 Memory device at locationarg1is in a power save state.
Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM1016 Memory device at locationarg1is not installed correctly.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE MEM1200 Message Memory RAID is redundant.
Detailed Description None Recommended Response Action Re-install the memory component. If the problem continues, contact support. Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory RAID lost on . Power cycle system Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE MEM1204 Message Memory mirror is redundant.
Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Recommended Response Action Review system logs for memory exceptions. Re-install memory at location Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Memory mirror lost on . Power cycle system Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM1208 Memory spare redundancy is lost. Check memory device at locationarg1.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE MEM1210 Message Memory is redundant.
Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM1214 Message Memory redundancy is degraded. Detailed Description The memory may not be seated correctly, misconfigured, or has failed.
Trap/EventID 2267 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM7002 Message A hardware mismatch detected for memory riser.
LCD Message SBE log disabled on . Reseat memory Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE MEM8001 Persistent correctable memory error logging enabled for a memory device at locationarg1. Message Arguments • arg1 = location Detailed Description None Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE MEM6000 Message Memory device monitoring is disabled. Detailed Description The memory module may not be correctly seated, wrongly configured, or has failed. Recommended Response Action Review the Embedded System Management (ESM) Log for memory exceptions. Re-install the memory modules.
LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE MEM6002 Memory device status is normal. Memory device location:arg1. Message Arguments • arg1 = location Detailed Description The memory device identified in the message has returned to a normal state. Recommended Response Action No response action is required.
Category System Health SubCategory MEM = Memory Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE MEM6004 Memory device status is critical. Memory device location:arg1, Possible memory module event cause:arg2.
• arg2 = cause Detailed Description The memory module failed because of an irrecoverable error. Recommended Response Action Review the Embedded System Management (ESM) Log for memory exceptions. Remove the old memory module and install a new memory module at the identified location . Category System Health SubCategory MEM = Memory Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
28 NIC Event Messages NIC100 The NICarg1Portarg2network link is down. Message Arguments • • arg1 = Controller arg2 = Port Detailed Description The network link is down. Either the network cable is not connected or the network device is not working. Recommended Response Action Verify that the network port is enabled and if the port has Activity/Speed LEDs, that they are lit. Check the network cable, network cable connections, and the attached network switch.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE NIC001 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC003 Message Missing required parameter Detailed Description An invalid number of arguments was passed to the method. Recommended Response Action Enter all the required command parameters. Check documentation and try again.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC005 Message Mismatch in AttributeName and AttributeValue count Detailed Description The number of AttributeName and AttributeValue parameters do not match. Recommended Response Action Pass the same number of parameters for AttributeName and AttributeValue. Refer to documentation for method input parameter details.
NIC007 Message Configuration job already created, cannot create another config job on specified target until existing job is completed or is cancelled Detailed Description Configuration job already created on the specified target. No further command is allowed until the existing job succeeded or the job is cancelled. Recommended Response Action Wait for the job to complete; to continue with a configuration change, cancel the job and proceed.
NIC009 Message Lifecycle Controller is currently in use. Detailed Description Lifecycle Controller cannot gain access to internal storage due to use by another application or operation. Recommended Response Action Wait for current Lifecycle Controller operation to complete. Verify that the system is 1) Not currently in Lifecycle Controller Unified Server Configurator 2) Not waiting for user intervention at F1/F2 POST error 3) Not in any of the device or controller Option ROMs and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC011 Message Configuration job already created, pending data cannot be deleted Detailed Description Configuration job already created on the specified target. No further command is allowed until the existing job is completed Recommended Response Action Cancel the configuration job or wait for the job to complete.
NIC013 Invalid AttributeName:arg1 Message Arguments • arg1 = attribute name Detailed Description Wrong AttributeName was entered. Recommended Response Action Enter the correct AttributeName available in the system. Refer to the enumeration response for desired attribute. Category Configuration SubCategory NIC = NIC Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC015 AttributeValue cannot be changed to read only AttributeNamearg1. Message Arguments • arg1 = attribute name Detailed Description A set attribute operation was attempted on a read only attribute. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC500 Message The requested object is not allowed to be configured if DHCP \nis enabled. Detailed Description The values of IP Address is not allowed to change if DHCP is enabled. Recommended Response Action Disable DHCP and then modify the value.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC502 Message DHCP is required to be enabled on the NIC before DHCP can be \nenabled for DNS server or domain name objects. Detailed Description The value of the specified parameter cannot be changed. Recommended Response Action Enable DHCP on the NIC before enabling it for DNS.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC504 Message The IPv6 DNS Server IP address is not allowed to be configured if\n IPv6 DNS Server DHCP (cfgIPv6DNSServersFromDHCP6) is enabled Detailed Description The value of the specified parameter cannot be changed. Recommended Response Action Disable the cfgIPv6DNSServersFromDHCP6 object.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC506 Message The requested object requires DNS registration to be enabled. Detailed Description The requested operation requires the DNS registration to be enabled. Recommended Response Action Enable the DNS registration.
NIC508 Message NIC teaming info is not currently available. Detailed Description None. Recommended Response Action No response action is required. Category System Health SubCategory NIC = NIC Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Success message. Recommended Response Action No response action is required. Category System Health SubCategory NIC = NIC Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory NIC = NIC Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC513 Message DHCP6 is already ENABLED Detailed Description Success message. Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE NIC515 Message DHCP6 is now ENABLED Detailed Description Success message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE 558 FALSE FALSE
29 OSD Event Messages OSD1 Message The command was successful. Detailed Description The command was successful. Recommended Response Action No response action is required. Category Configuration SubCategory OSD = OS Deployment Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD3 Message Lifecycle Controller is being used by another process. Detailed Description Lifecycle Controller is currently locked by another process. Make sure that the process completes before attempting to run another command. Recommended Response Action 1) After two minutes, rerun the command.
OSD5 Message Lifecycle Controller Driver Pack not found. Detailed Description A Driver Pack was not found on the Lifecycle Controller. Recommended Response Action Update the Driver Pack using USC or DUP and then run the command again. Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Unable to connect to Lifecycle Controller because of an existing open connection or an internal error. Recommended Response Action Reset iDRAC, and rerun the command to correct the problem. Category Configuration SubCategory OSD = OS Deployment Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory OSD = OS Deployment Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD10 Message Installation not supported for the selected operating system. Detailed Description Installation for the selected operating system is not supported.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD12 Message Cannot create the USB device needed to copy drivers for the selected operating system. Detailed Description iDRAC was unable to create and expose the drivers as a USB device for the OS installation to proceed.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD14 Message Unable to expose the USB device that contains the operating system drivers to host system. Detailed Description iDRAC was unable to expose the drivers as a USB device for the OS installation to proceed. Recommended Response Action 1) Rerun the command. 2) Reset iDRAC and rerun the command.
OSD16 Message Mount network share failed - incorrect IP address or share name. Detailed Description Unable to mount the network share using the parameters specified in the command because either the IP address or share name is incorrect. Recommended Response Action Rerun the command with the correct IP address and share name. Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
OSD18 Message Unable to locate the ISO image on the network share point. Detailed Description Unable to find the ISO file specified in the network share. Make sure that the correct ISO file path was entered into the command and that all other user credentials are correct. Recommended Response Action Rerun the command with the correct ISO file path.
Detailed Description Unable to get the size or label for selected operating system from the Driver Pack present in Lifecycle Controller. The driver pack may be corrupt. Recommended Response Action Update the Driver Pack using USC or DUP and rerun the command. Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory OSD = OS Deployment Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD23 Message Unable to continue with DetachISOImage - another command is in the process of exposing the ISO Image and booting to it.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD25 Message Unable to detach USB device containing operating system drivers. Detailed Description Detaching the USB device (that contains drivers for the operating system installation) from the host has failed.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD27 Message Copying drivers for selected operating system failed. Detailed Description Copying drivers for selected operating system failed. The Driver Pack may be unusable. Recommended Response Action Update the Driver Pack using USC or DUP and then rerun the command.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD29 Message Driver Pack configuration file not found in Lifecycle Controller. The Driver Pack might be corrupt. Detailed Description Driver Pack config file not found in Lifecycle Controller. Driver Pack may be unusable. Recommended Response Action Update the Driver Pack using USC or DUP and then rerun the command.
OSD31 Message Copying operating system drivers to network share failed Detailed Description Copying drivers for the selected operating system to network share failed. The share may be read-only or the Driver Pack present in Lifecycle Controller may be unusable. Recommended Response Action 1) Make sure that the network share has write permission. 2) Update the Driver Pack using USC or DUP and then rerun the command.
Detailed Description The system has an older version of BIOS that does not support this method. Install the latest version of BIOS to use this method. Recommended Response Action Update the BIOS to version 1.2 or later and then rerun the command. Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Reboot the system and enable System Services by pressing CTRL+E option when prompted to do so in the POST. This launches the iDRAC configuration utility where Lifecycle Controller can be enabled. Category Configuration SubCategory OSD = OS Deployment Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SubCategory OSD = OS Deployment Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD38 Message Copying the ISO image from the network failed. Detailed Description There was an error while copying the ISO from the network share.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD40 Message VFlash is not Dell licensed. Detailed Description This is not a Dell-licensed VFlash. Recommended Response Action Insert a Dell VFlash and then retry this command.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD42 Message Downloading ISO File to VFlash failed. Detailed Description There was an error while copying the ISO image from the network share to the VFlash. Recommended Response Action 1) Make sure the network connection is working. 2) Make sure the Dell VFlash doesnt have any hardware issues by accessing it through the iDRAC GUI.
OSD44 Message Unable to detach ISO image on VFlash. Detailed Description The ISO on VFlash is not currently attached, so the DetachISOFromVFlash command could not be executed. Recommended Response Action Since the ISO image is not attached, the detachISOFromVflash command does not have to be run. Category Configuration SubCategory OSD = OS Deployment Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Another process (iDRAC GUI /racadm/iDRAC configuration utility) is currently accessing VFlash. Recommended Response Action Wait until the access to VFlash is relinquished and then retry this command. Category Configuration SubCategory OSD = OS Deployment Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD49 Message Disable RIPS mode to access VFlash. Detailed Description VFlash cannot be accessed because RIPS mode is enabled.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD51 Message Reboot the system to run pending System Services Tasks. Detailed Description There are pending System Services tasks on the host system that are preventing the execution of this method. Recommended Response Action Reboot the host system.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD53 Message vFlash is write protected. Detailed Description vFlash is write protected. Recommended Response Action Remove the write protect from the SD card and then proceed Category Configuration SubCategory OSD = OS Deployment Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
OSD55 Message ISO Image is attached to host Detailed Description Cannot attach the ISO image since it is already attached to the host. Recommended Response Action ISO Image is already attached to the host server. Detach the ISO and then rerun the command Category Configuration SubCategory OSD = OS Deployment Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Remote File Share (RFS) is currently configured to be in auto-attach mode. For Web services to attach an ISO, RFS should be changed to attach mode. Recommended Response Action Change the Remote File Share (RFS) mode to Attach using iDRAC GUI or Remote Services API and retry. Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory OSD = OS Deployment Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE OSD60 Message Unable to connect to ISO using Remote File Share (RFS). Detailed Description Connecting ISO using Remote File Share (RFS) was unsuccessful.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
30 OSE Event Messages OSE0000 Message A critical stop occurred during OS load. Detailed Description The system halted due to an exception during operating system load or operating system initialization. Recommended Response Action Review operating system logs and system video for additional information Category System Health SubCategory OSE = OS Event Severity Severity 1 (Critical) Trap/EventID 2409 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE OSE0002 Message An OS graceful stop occurred. Detailed Description (IPMI sensor type 20h - offset 02h). Recommended Response Action No response action is required. Category System Health SubCategory OSE = OS Event Severity Severity 3 (Informational) Trap/EventID 2411 LCD Message No LCD message display defined. Initial Default.
OSE0004 Message A soft shut-down initiated by platform event filter. Detailed Description A separate exception or status condition shutdown the operating system. (IPMI sensor type 20h - offset 04h). Recommended Response Action Review system event log for platform events capable of shutting the system down. Category System Health SubCategory OSE = OS Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The system OS has successfully booted from A: Recommended Response Action No response action is required. Category System Health SubCategory OSE = OS Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory OSE = OS Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE OSE1003 Message Failed to boot from C. Detailed Description None Recommended Response Action Review system boot configuration and boot media.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE OSE1005 Message PXE boot failed.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE OSE1007 Message Diagnostic boot failed. Detailed Description None Recommended Response Action Review system boot configuration and boot media. See system video for additional information Category System Health SubCategory OSE = OS Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined.
OSE1009 Message Failed to boot from CD-ROM. Detailed Description None Recommended Response Action Review system boot configuration and boot media. Verify the media in the CDROM is bootable. See system video for additional information Category System Health SubCategory OSE = OS Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action Check system event logs for additional exception information. Power down the system and attempt to boot again. Category System Health SubCategory OSE = OS Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory OSE = OS Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
31 PCI Event Messages PCI1300 Message A front panel diagnostic interrupt was detected. Detailed Description The front panel diagnostic was pressed, and the system may be halted as a result. The interrupt was user induced. Recommended Response Action Reset the system to continue operation. Category System Health SubCategory PCI = PCI Device Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Trap/EventID 2417 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1304 Message An I/O channel check error was detected. Detailed Description None Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device.
Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1308 A PCI parity error was detected on a component at busarg1devicearg2functionarg3.
Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device. Category System Health SubCategory PCI = PCI Device Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message PCI system error on bus device function . Power cycle system. Initial Default.
Detailed Description System performance may be degraded. Recommended Response Action Cycle input power, update component drivers, if device is removable re-install the device at the next scheduled service time. Category System Health SubCategory PCI = PCI Device Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message No LCD message display defined. Initial Default.
PCI1318 A fatal error was detected on a component at busarg1devicearg2functionarg3. Message Arguments • • • arg1 = bus arg2 = device arg3 = func Detailed Description System performance may be degraded, or system may fail to operate. Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1322 Bus performance degraded for a component at busarg1devicearg2functionarg3. Message Arguments • • • arg1 = bus arg2 = device arg3 = func Detailed Description System performance may be degraded. The bus is not operating at maximum speed or width.
Trap/EventID 2417 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1344 Message An I/O channel check error was detected. Detailed Description None Recommended Response Action Cycle input power, update component drivers, if device is removable, re-install the device.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1348 A PCI parity error was detected on a component at slotarg1. Message Arguments • arg1 = number Detailed Description System performance may be degraded, or system may fail to operate.
Trap/EventID 2417 LCD Message PCI system error on slot . Reseat PCI card Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1354 A bus correctable error was detected on a component at slotarg1. Message Arguments • arg1 = number Detailed Description System performance may be degraded.
Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1358 A fatal error was detected on a component at slotarg1. Message Arguments • arg1 = number Detailed Description System performance may be degraded, or system may fail to operate.
SubCategory PCI = PCI Device Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message Bus fatal error on slot . Reseat PCI card Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI1362 Bus performance degraded for a component at slotarg1. Message Arguments • arg1 = number Detailed Description System performance may be degraded.
Recommended Response Action Cycle input power, update component drivers, remove and re-install the device. Category System Health SubCategory PCI = PCI Device Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message Fatal IO error on bus device function . Contact support Initial Default.
Detailed Description System performance may be degraded, or system may fail to operate. Recommended Response Action Cycle input power, update component drivers, remove and re-install the device. Category System Health SubCategory PCI = PCI Device Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message Fatal IO error on slot . Contact support Initial Default.
Detailed Description Either the BIOS, BMC/iDRAC, or LOM firmware is out of date and does not support FlexAddress. Recommended Response Action Update BIOS, BMC/iDRAC, and LOM firmware. If problem persists please contact customer support. Category System Health SubCategory PCI = PCI Device Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message No LCD message display defined. Initial Default.
Detailed Description Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and does not support FlexAddress. Recommended Response Action Update BIOS, BMC/iDRAC, LOM, and mezzanine card firmware. If problem persists please contact customer support. Category System Health SubCategory PCI = PCI Device Severity Severity 1 (Critical) Trap/EventID 2417 LCD Message No LCD message display defined. Initial Default.
PCI3004 Device option ROM on mezzanine cardarg1failed to support Link Tuning or FlexAddress. Message Arguments • arg1 = number Detailed Description Either the BIOS, BMC/iDRAC, or mezzanine card firmware is out of date and does not support FlexAddress. Recommended Response Action Update BIOS, BMC/iDRAC, and mezzanine card firmware. If problem persists please contact customer support.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI3006 Message Failed to get Link Tuning or FlexAddress data from iDRAC. Detailed Description Either the BIOS or BMC/iDRAC firmware is out of date and does not support FlexAddress. Recommended Response Action Update BIOS, and BMC/iDRAC firmware. If problem persists please contact customer support.
PCI3008 A non-fatal PCIe error detected on a component at busarg1devicearg2functionarg3. Message Arguments • • • arg1 = bus arg2 = device arg3 = func Detailed Description System performance may be degraded. Recommended Response Action Cycle input power, update component drivers, remove and re-install the device at the next service window. Category System Health SubCategory PCI = PCI Device Severity Severity 2 (Warning) Trap/EventID 2418 LCD Message No LCD message display defined.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI3010 A non-fatal IO error detected on a component at busarg1devicearg2functionarg3. Message Arguments • • • arg1 = bus arg2 = device arg3 = func Detailed Description System performance may be degraded.
SubCategory PCI = PCI Device Severity Severity 3 (Informational) Trap/EventID 2419 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI3012 Message The QuickPath Interconnect (QPI) width degraded. Detailed Description System performance may be degraded. The bus is not operating at maximum speed or width.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI3014 A non-fatal PCIe error detected on a component at slotarg1. Message Arguments • arg1 = number Detailed Description System performance may be degraded.
Trap/EventID 2419 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI3016 Message Device option ROM on mezzanine card failed to support Link Tuning or FlexAddress. Detailed Description Either the BIOS, BMC/iDRAC, or mezzanine card firmware is out of date and does not support FlexAddress.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PCI3018 Message PCI card(s) have been detected in the system that may require additional fan speed configuration for proper operation. Detailed Description PCI card(s) have been detected in the system that may require additional airflow.
32 PDR Event Messages PDR1 arg1copyback stopped for rebuild. Message Arguments • arg1 = physical disk Detailed Description This message is generated after a copyback stops on a physical disk during a rebuild operation. Recommended Response Action Wait for rebuild to finish, then copyback should resume. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) Trap/EventID 4346 LCD Message No LCD message display defined. Initial Default.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR100 Dedicated Hot Sparearg1no longer useful for all arrays. Message Arguments • arg1 = PD Name Detailed Description The controller is not able to communicate with a disk that is assigned as a dedicated hot spare. The disk may have been removed.
SubCategory PDR = Physical Disk Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR11 arg1rebuild was cancelled. Message Arguments • arg1 = physical disk Detailed Description A user has cancelled the rebuild operation.
Category Storage SubCategory PDR = Physical Disk Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR13 arg1rebuild has failed. Message Arguments • arg1 = physical disk Detailed Description A physical disk included in the virtual disk has failed or is corrupted.
Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR15 arg1rebuild is complete.
Detailed Description The physical disk is predicted to fail. Many physical disks contain Self Monitoring Analysis and Reporting Technology (SMART). When enabled, SMART monitors the disk health based on indications such as the number of write operations that were performed on the disk. Recommended Response Action Replace the physical disk. Even though the disk may not have failed yet, it is strongly recommended that the disk be replaced. Review other messages for additional information.
Arguments • arg1 = PD Name Detailed Description A physical disk assigned as a hot spare was unassigned and is no longer functioning as a hot spare. The physical disk was unassigned by a user or automatically unassigned by Storage Management. Storage Management unassigns hot spares were used to rebuild data. Once the data is rebuilt onto the hot spare, the hot spare becomes a member of the virtual disk and is no longer assigned as a hot spare.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR2 Insufficient space available onarg1to perform a copyback operation. Message Arguments • arg1 = physical disk Detailed Description This message is generated if a physical disk does not have enough space to do a copyback operation.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR21 SMART warning forarg1 Message Arguments • arg1 = PD Name Detailed Description A disk has received a SMART alert (predictive failure). The disk is likely to fail in the near future. Recommended Response Action Replace the disk that has received the SMART alert.
information. 4) If you cannot identify why the disk has reached an unacceptable temperature, then replace the disk. If the physical disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. Removing a physical disk that is included in a nonredundant virtual disk causes the virtual disk to fail and may cause data loss. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined.
Arguments • arg1 = PD Name Detailed Description A disk has received a SMART alert (predictive failure) due to test conditions. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
PDR26 arg1is online. Message Arguments • arg1 = physical disk Detailed Description A previously offline physical disk is now online. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR28 Dedicated hot spare unassigned fromarg1. Message Arguments • arg1 = PD Name Detailed Description A physical disk that was assigned as a hot spare has been unassigned and is no longer functioning as a hot spare. The physical disk was unassigned by a user or automatically unassigned by Storage Management.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR3 arg1has failed. Message Arguments • arg1 = physical disk Detailed Description A storage physical disk has failed. Recommended Response Action Replace the failed disk.
Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR31 A global hot spare has been removed.
Recommended Response Action Verify that the disk is healthy and installed. Check the cables. Refer to the product documentation and see the Cables Attached Correctly section for more information on checking the cables. If necessary, replace the disk and reassign the global hot spare. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The hot spare is no longer required because the virtual disk it was assigned to has been deleted. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = PD Name Detailed Description The only physical disk available to be assigned as a hot spare is using SAS technology. The physical disks in the virtual disk are using SATA technology. Because of this difference in technology, the hot spare cannot rebuild data if one of the physical disks in the virtual disk fails. Recommended Response Action Add a SATA disk that is large enough to be used as the hot spare and assign the new disk as a hot spare.
PDR38 A clear operation started onarg1. Message Arguments • arg1 = physical disk Detailed Description A user has initiated a clear operation on a physical disk. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR4 arg1returned to a ready state. Message Arguments • arg1 = physical disk Detailed Description A physical drive that was previously in an error state has returned to a ready state. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR41 The clear operation onarg1was cancelled. Message Arguments • arg1 = physical disk Detailed Description The clear command did not complete on the physical disk. This means that some data was not cleared and may be recoverable. Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR43 The clear operation onarg1has completed. Message Arguments • arg1 = physical disk Detailed Description This message is generated after a clear operation completes on a physical disk. Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 4345 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PDR46 Patrol Read found an uncorrectable media error onarg1. Message Arguments • arg1 = physical disk Detailed Description The Patrol Read task has encountered an error that cannot be corrected.
Recommended Response Action Back up the data from the disk. Start disk initialization and wait for it to complete, and then restore the data from a backup copy. Category Storage SubCategory PDR = Physical Disk Severity Severity 1 (Critical) Trap/EventID 4345 LCD Message No LCD message display defined. Initial Default.
Detailed Description The dedicated hot spare is not large enough to protect all virtual disks that reside on the disk group. Recommended Response Action Assign a larger disk as the dedicated hot spare. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) Trap/EventID 4346 LCD Message No LCD message display defined. Initial Default.
PDR50 Insufficient space on the global hot sparearg1. Message Arguments • arg1 = PD Name Detailed Description The global hot spare is not large enough to protect all virtual disks that reside on the controller. Recommended Response Action Assign a larger disk as the global hot spare. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) Trap/EventID 4346 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PDR52 Message A redundant path is broken. Detailed Description The controller has two connectors that are connected to the same enclosure. The communication path on one connector has lost connection with the enclosure. The communication path on the other connector is reporting this loss.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE PDR54 A disk media error onarg1was corrected during recovery. Message Arguments • arg1 = physical disk Detailed Description This message is generated after a disk media error is corrected on a physical disk. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PDR56 Bad block table onarg1is 80% full. Message Arguments • arg1 = physical disk Detailed Description The bad block table is the table used for remapping bad disk blocks. This table fills as bad disk blocks are remapped.
SubCategory PDR = Physical Disk Severity Severity 1 (Critical) Trap/EventID 4345 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PDR58 arg1is incompatible. Message Arguments • arg1 = PD Name Detailed Description A user attempted to replace a disk with another disk that is using an incompatible technology.
Recommended Response Action Monitor the disk for other messages or indications of poor health. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR6 arg1is offline.
Detailed Description The reason for the error can vary depending on the situation. The firmware error code is indicated in the message. Recommended Response Action Verify the health of attached devices. Review the Lifecycle log for significant events. Replace faulty hardware, if required. Make sure the cables are attached securely. Refer to the storage hardware documentation for more information on checking the cable connections.
Arguments • arg1 = physical disk Detailed Description It is not possible to rebuild data that resides on a defective disk. Recommended Response Action Replace the target disk. If a rebuild does not automatically start after replacing the disk, then initiate the Rebuild task. You may need to assign the new disk as a hot spare to initiate the rebuild. Category Storage SubCategory PDR = Physical Disk Severity Severity 1 (Critical) Trap/EventID 4345 LCD Message No LCD message display defined.
PDR64 An unrecoverable disk media error occurred onarg1. Message Arguments • arg1 = physical disk Detailed Description The rebuild or recovery operation encountered an unrecoverable disk media error. Recommended Response Action Replace the disk. Category Storage SubCategory PDR = Physical Disk Severity Severity 1 (Critical) Trap/EventID 4345 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR66 arg1that was marked as missing has been replaced. Message Arguments • arg1 = physical disk Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR68 Dedicated sparearg1imported as global due to missing disk groups. Message Arguments • arg1 = PD Name Detailed Description This alert is provided for informational purposes Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE PDR7 arg1has degraded. Message Arguments • arg1 = physical disk Detailed Description A physical disk has reported an error condition and may be degraded. The physical disk may have reported the error condition in response to a check consistency or other operation.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR71 Copyback completed fromarg1toarg2. Message Arguments • • arg1 = physical disk arg2 = physical disk Detailed Description The copyback operation completed. Recommended Response Action No response action is required.
SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR73 Copyback failed fromarg1toarg2.
Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR75 Copyback stopped for hot sparearg1.
Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR77 arg1state changed from READY to Non-RAID.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = PD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
PDR82 arg1security was activated. Message Arguments • arg1 = physical disk Detailed Description Security on a secure encrypted disk was activated. Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE TRUE PDR84 arg1Security key has changed. Message Arguments • arg1 = physical disk Detailed Description The Security key on a secure encrypted disk was activated. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PDR86 Bad block table onarg1is full. Message Arguments • arg1 = physical disk Detailed Description The number of blocks on the disk that exhibit an error has exceeded the capacity of the drive to remap. Any future writes to bad sectors will be unrecoverable. Recommended Response Action Replace the disk.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR88 Power state change failed onarg1. (fromarg2toarg3) Message Arguments • • • arg1 = PD Name arg2 = state arg3 = state Detailed Description When physical drives in spun down power state are configured, the drives should transition to spun up power state..
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR93 Microcode update onarg1has completed. Message Arguments • arg1 = physical disk Detailed Description The physical disk firmware update operation has completed.
SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR95 Microcode update onarg1has failed. Message Arguments • arg1 = physical disk Detailed Description The attempt to update the physical disk has failed.
Recommended Response Action No response action is required. Category Storage SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR97 arg1security key must bearg2arg3.
• arg2 = args Detailed Description An error occurred while performing an action on the disk. Recommended Response Action Check the disk is present or replace the disk. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) Trap/EventID 4346 LCD Message No LCD message display defined. Initial Default.
PDR1001 Fault detected on drivearg1in disk drive bayarg2. Message Arguments • • arg1 = number arg2 = bay Detailed Description The controller detected a failure on the disk and has taken the disk offline. Recommended Response Action Remove and reseat the failed drive. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE PDR1003 Drivearg1in disk drive bayarg2is the hot-spare drive. Message Arguments • • arg1 = number arg2 = bay Detailed Description None Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PDR1005 Drivearg1in disk drive bayarg2is in the critical array. Message Arguments • • arg1 = number arg2 = bay Detailed Description None Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message Drive in disk drive bay is in the failed array. Replace drive. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PDR1007 Rebuild is in progress for drivearg1in disk drive bayarg2.
Category System Health SubCategory PDR = Physical Disk Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PDR1016 Drivearg1is removed from disk drive bayarg2.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID 2299 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PDR1019 Drivearg1in disk drive bayarg2is no longer the hot-spare drive.
Arguments • • arg1 = number arg2 = bay Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
PDR1022 Drivearg1in disk drive bayarg2is no longer in the failed array. Message Arguments • • arg1 = number arg2 = bay Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR1024 Drive mismatch detected for drivearg1in disk drive bayarg2. Message Arguments • • arg1 = number arg2 = bay Detailed Description The installed disk does not meet the array requirements, for example a SATA disk may not operate in an array containing SAS drives. Recommended Response Action Verify the disk meets the array requirements.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE PDR1100 Drivearg1is installed. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required.
Trap/EventID 2297 LCD Message Fault detected on drive . Check drive. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PDR1102 A predictive failure detected on drivearg1. Message Arguments • arg1 = number Detailed Description The controller received a SMART error from the drive. The drive is operational but needs replacement.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PDR1104 Consistency check is in progress for drivearg1. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required.
SubCategory PDR = Physical Disk Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message Drive is in the critical array. Replace drive. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PDR1106 Drivearg1is in the failed array. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required.
Category System Health SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PDR1108 Rebuild was aborted for drivearg1.
Recommended Response Action If unintended, verify drive installation. Remove and reseat the indicated disk. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory PDR = Physical Disk Severity Severity 1 (Critical) Trap/EventID 2297 LCD Message Drive is removed. Check drive Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PDR1120 Consistency check for drivearg1completed.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PDR1122 Drivearg1is no longer in the failed array.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = physical disk name Detailed Description Unable to assign the physical disk as a dedicated hot spare because the selected disk size does not meet the size requirements of the target Virtual Disk. Recommended Response Action Select a physical disk that matches the size required for the disks used in the target Virtual Disk, and retry the operation.
PDR209 The power status ofarg1is changed fromarg2toarg3. Message Arguments • • • arg1 = physical disk name arg2 = previous power status arg3 = current power status Detailed Description The Manage Physical Disk Power feature is enabled for physical drives and the power status of the drives changed. Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR211 arg1has encountered storage medium error. Message Arguments • arg1 = physical disk name Detailed Description Storage medium error was detected on the disk identified in the message. Recommended Response Action No response action is required.
SubCategory PDR = Physical Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PDR213 The state ofarg1changed from Non-RAID to Ready.
Recommended Response Action Replace the physical disk with a supported physical disk that is provided by an authorized hardware provider. Category Storage SubCategory PDR = Physical Disk Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
33 POW Event Messages POW000 Message Power on permission error, chassis infrastructure not ready. Detailed Description Host failed to power up bacause chassis infrastructure is not ready. Recommended Response Action Check status of chassis infrastructure. Category Audit SubCategory POW = Power Usage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE POW002 Message Power on permission error, unknown component installed in Fabric1/Fabric2. Detailed Description Host failed to power up because unsupported components installed in Fabric1/fabric2. Recommended Response Action Check for unsupported components installed in Fabric1/Fabric2.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE TRUE TRUE FALSE FALSE FALSE FALSE FALSE POW004 Message Power on permission error, unacknowledge use of 110V. Detailed Description Host failed to power up because of unacknowledged use of 110V. Recommended Response Action Check for unacknowledged use of 110V.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE TRUE TRUE FALSE FALSE FALSE 700 FALSE FALSE
34 PR Event Messages PR1 A replacement part was detected for device:arg1 Message Arguments • arg1 = device name Detailed Description The specified device has been replaced. Recommended Response Action No response action is required. Category Configuration SubCategory PR = Part Exchange Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR3 Newer version of firmware found on device:arg1 Message Arguments • arg1 = device name Detailed Description The current component firmware version is higher than the replaced component firmware version.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SubCategory PR = Part Exchange Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR7 New device detected:arg1 Message Arguments • arg1 = device name Detailed Description The specified device was added to the system.
Category Configuration SubCategory PR = Part Exchange Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR9 Message Firmware update operation initiated.
Category Configuration SubCategory PR = Part Exchange Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR11 Message A required license for the Part Replacement feature is not present, replacement action(s) will not be performed.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR13 Message Firmware mismatch detected. Configuration changes not applied. Detailed Description The Part Replacement feature deteced a firmware difference and cannot apply the configuration changes.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SubCategory PR = Part Exchange Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action No response action is required. Category Configuration SubCategory PR = Part Exchange Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR19 Message Job completed successfully.
SubCategory PR = Part Exchange Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR21 Message Job failed. Detailed Description The indicated job has failed.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR23 Message Job is ready for execution. Detailed Description The specified job is ready to start. It is waiting for scheduling from job control. This message is no longer in use in Lifecycle Controller 2.0 as the job control functionality handles this operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR25 Message Missing or corrupt configuration database. Detailed Description The systems configuration database is missing or is unreadable. This may be due to a user action such as Lifecycle Controller Wipe or a replaced motherboard.
PR27 Message Unable to allocate resources. Detailed Description The system ran out of memory while attempting to perform an operation. This has been deprecated. Recommended Response Action Retry the operation. If more than one operation was attempted retry them one at a time. Category Configuration SubCategory PR = Part Exchange Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The device that the job was intended for has no previous information recorded. The request has failed as this information is required to initiate the operation. This has been deprecated. Recommended Response Action Enable the Collect System Inventory on Restart attribute of the Lifecycle Controller and restart the system. Alternatively, use the Unified Server Configurator utility.
Category Configuration SubCategory PR = Part Exchange Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PR32 Message Failed verification of configuration changes.
35 PST Event Messages PST0128 Message No memory is detected. Detailed Description System BIOS was unable to detect memory in the system . This exception occurred early in system power on, thus the system may not display video (BIOS Post Exception 80). Recommended Response Action Inspect System Memory. Category System Health SubCategory PST = BIOS POST Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message No memory is detected. Inspect memory devices Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PST0130 Message Memory is configured, but not usable. Detailed Description During memory configuration system BIOS encountered device failures or speed configurations that resulted in unused memory. This exception occurred early in system power on, thus the system may not display video.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PST0132 Message CMOS failed. Detailed Description System BIOS detected a failure with CMOS memory during system POST. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception Code 84) Recommended Response Action Check system event log for CMOS battery exceptions.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PST0134 Message Interrupt controller failed. Detailed Description System BIOS detected a failure with the interrupt controller during system POST. This exception occurred early in system power on, thus the system may not display video. (BIOS POST Exception code 86) Recommended Response Action Remove and reapply input power.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PST0136 Message Programmable interval timer error. Detailed Description System BIOS detected an failure with the programmable interval timer during POST. This exception occurred early in system power on, thus the system may not display video.(BIOS POST Exception code 88) Recommended Response Action Remove and reapply input power.
PST0138 Message SuperIO failed. Detailed Description System BIOS detected a failure with the SIO. This exception occurred early in system power on, thus the system may not display video. (BIOS POST code exception code 8A) Recommended Response Action Remove and reapply input power. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Detailed Description System BIOS failed to initialize the system management interrupt. This exception occurred early in system power on, thus the system may not display video. (BIOS POST exception code 8C) Recommended Response Action Remove and reapply input power. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Recommended Response Action Compare system memory installation to supported system memory configurations. Reduce system configuration to minimum memory configuration. Category System Health SubCategory PST = BIOS POST Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message Memory initialization error. Contact support Initial Default.
Category System Health SubCategory PST = BIOS POST Severity Severity 1 (Critical) Trap/EventID 2425 LCD Message Shut-down test failed. Power cycle system Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PST0193 Message BIOS POST memory test failed. Detailed Description System BIOS POST memory test failed.
Trap/EventID 2425 LCD Message Remote access controller configuration failed. Check screen message Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PST0195 Message CPU configuration failed. Detailed Description The current processor configuration is unsupported or encountered a fatal exception during POST. Check the processor configuration.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PST0254 Message General failure after video. Detailed Description System BIOS detected a functional or configuration issue during system POST. Check the system video screen for more information. The system event log may contain additional details.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE 728 TRUE FALSE
36 PSU Event Messages PSU1000 Power supply cable has been removed fromarg1. Message Arguments • arg1 = PSU Sensor Name Detailed Description The power supply unit is not receiving input AC power. The power cable may not be connected properly or removed. This can happen if there is an AC failure or problems with the power strip attached to the enclosure power supply. Recommended Response Action Reconnect the power cable to the power supply unit if it was disconnected.
Severity Severity 1 (Critical) Trap/EventID 4233 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PSU1002 arg1was removed Message Arguments • arg1 = PSU Sensor Name Detailed Description The enclosure detected that a power supply unit was removed and is no longer functioning in optimal condition.
Category Storage SubCategory PSU = Power Supply Severity Severity 2 (Warning) Trap/EventID 4234 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PSU1004 Power supply cable has been inserted intoarg1.
Recommended Response Action No response action is required. Category Storage SubCategory PSU = Power Supply Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PSU1006 arg1was inserted.
Detailed Description A device has been failed and the system is no longer functioning in optimal condition. Recommended Response Action Replace the device. Category Storage SubCategory PSU = Power Supply Severity Severity 1 (Critical) Trap/EventID 4233 LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PSU = Power Supply Severity Severity 3 (Informational) Trap/EventID 2187 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PSU0001 Power supplyarg1failed.
Detailed Description System performance and power redundancy may be degraded or lost. Recommended Response Action Remove and re-install the power supply at the next service window. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory PSU = Power Supply Severity Severity 2 (Warning) Trap/EventID 2186 LCD Message Predictive failure on PSU . Check PSU Initial Default.
Arguments • arg1 = number Detailed Description The operating requirements for the power supply may be found in product documentation or on the power supply itself. Recommended Response Action Verify the input source is attached to the power supply. Verify the input power is within the operating requirements for the power supply. Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message Power input for PSU is outside of range.
PSU0006 Power supplyarg1is incorrectly configured. Message Arguments • arg1 = number Detailed Description Power supplies should be of the same input type and power rating. Recommended Response Action Install matched power supplies and review product documentation for proper configuration. Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message Power supply is incorrectly configured. Check PSU. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PSU0017 Power supplyarg1is operating normally. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PSU = Power Supply Severity Severity 3 (Informational) Trap/EventID 2187 LCD Message No LCD message display defined.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE TRUE PSU0022 Power supplyarg1is correctly configured. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PSU0031 Cannot communicate with power supplyarg1. Message Arguments • arg1 = number Detailed Description The power supply may operate, however power supply monitoring will be degraded. System performance may be degraded.
Trap/EventID 2186 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE PSU0033 The temperature for power supplyarg1is outside of range. Message Arguments • arg1 = number Detailed Description System performance may be degraded.
SubCategory PSU = Power Supply Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message An under voltage fault detected on PSU . Check power source. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE PSU0035 An over voltage fault detected on power supplyarg1.
Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) Trap/EventID 2185 LCD Message An over current fault detected on PSU . Check PSU. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE PSU0037 Fan failure detected on power supplyarg1.
Recommended Response Action No reponse action is required Category System Health SubCategory PSU = Power Supply Severity Severity 3 (Informational) Trap/EventID 2187 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PSU0039 An under current fault detected on power supplyarg1.
Detailed Description The power supply output voltage is insufficient to keep system operating at a normal levels. Recommended Response Action 1) Remove the power supply input cord and then remove power supply. 2) Re-install the power supply and then re-install the power supply cord. 3) If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Arguments • arg1 = number Detailed Description none Recommended Response Action 1) Remove the power supply input cord and then remove power supply. 2) Re-install the power supply and then re-install the power supply cord. 3) If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
PSU0044 Cannot obtain status information from power supplyarg1. Message Arguments • arg1 = number Detailed Description The power supply is operating but the system cannot get status information. Recommended Response Action If problem persist, remove and re-install power supply. Category System Health SubCategory PSU = Power Supply Severity Severity 2 (Warning) Trap/EventID 2186 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE TRUE PSU0046 Communication has been restored to power supplyarg1. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PSU = Power Supply Severity Severity 3 (Informational) Trap/EventID 2187 LCD Message No LCD message display defined.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE PSU0077 Power supplyarg1vendor type mismatch detected. Message Arguments • arg1 = number Detailed Description Power supplies should be of the same input type and power rating. Recommended Response Action Install matched power supplies and review product documentation for proper configuration.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE PSU0080 Power supplyarg1voltage rating does not match the systems requirements. Message Arguments • arg1 = number Detailed Description The system does not support mixed voltage power supplies.
Trap/EventID 2187 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE TRUE PSU0092 Power supplyarg1rating is acceptable. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PSU0901 Power unitarg1is on. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required.
SubCategory PSU = Power Supply Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PSU0904 Could not power down 240VA on power unitarg1. Message Arguments • arg1 = number Detailed Description In order to meet service requirements the supply must be shut down.
Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PSU0907 An interlock power down error was corrected for power unitarg1.
Recommended Response Action Verify the input source is attached to the power supply. Verify the input power is within the operating requirements for the power supply. Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The system did not respond correctly to a power down request. Recommended Response Action Disconnect Input Power Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Status from the power supply indicates a power supply exception occurred. The power supply will try to operate in a degraded state. System Performance and power redundancy may be degraded or lost. Recommended Response Action Check input power. Re-install the power supply. If problem persists contact support. Category System Health SubCategory PSU = Power Supply Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = number Detailed Description Status from the power supply indicates a power supply exception occurred. The power supply will try to operate. System Performance and power redundancy may be degraded or lost. Recommended Response Action Remove input power and re-install supply at the next service window. Category System Health SubCategory PSU = Power Supply Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
PSU101 Power supplyarg1is not present. Message Arguments • arg1 = power supply unit Detailed Description The power supply unit identified in the message is not present, because of the one of the following reasons: 1) The power supply unit is not correctly seated. 2) The power cable may not be connected properly or diconnected. 3) The power supply unit has failed. 4) There is an input power failure.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PSU1050 arg1is switched ON. Message Arguments • arg1 = power supply name Detailed Description The power supply identified in the message is switched ON. Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PSU501 Message Server is already powered ON. Detailed Description The server was already up, when the user gave a power on request. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PSU503 Server power status:arg1 Message Arguments • arg1 = Status Detailed Description Success message. Recommended Response Action No response action is required. Category System Health SubCategory PSU = Power Supply Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PSU0800 Power Supplyarg1: Status = 0xarg2, IOUT = 0xarg3, VOUT= 0xarg4, TEMP= 0xarg5, FAN = 0xarg6, INPUT= 0xarg7 Message Arguments • • • • • • • arg1 = PSU_name arg2 = PSU_Status arg3 = Output_Current arg4 = Output_Voltage arg5 = Temp arg6 = Fan arg7 = Input Detailed Description Lists the complete status of the power supply unit.
Category System Health SubCategory PSU = Power Supply Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PSU0802 Message The power supply redundancy policy on the system has been set.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
37 PSUA Event Messages PSUA0016 Power supplyarg1is absent. Message Arguments • arg1 = number Detailed Description The supply has been removed or has failed. Recommended Response Action Install the power supply if needed. Category System Health SubCategory PSUA = PSU Absent Severity Severity 1 (Critical) Trap/EventID 2465 LCD Message PSU is absent. Check PSU Initial Default.
38 PWR Event Messages PWR0100 Message The power button was pressed. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR0102 Message The sleep button was pressed. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
PWR0104 Message The reset button was pressed. Detailed Description The system will reset. Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR0107 Thearg1is unlatched.
PWR0108 Thearg1service was requested. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR1000 Message The system performance restored. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID 2275 LCD Message No LCD message display defined. Initial Default.
PWR1002 Message The system performance degraded because of thermal protection. Detailed Description To avoid shutdown, system performance has been degraded. Recommended Response Action Review system configuration and system logs for thermal or environmental failures and warnings. Category System Health SubCategory PWR = Power Usage Severity Severity 2 (Warning) Trap/EventID 2274 LCD Message No LCD message display defined. Initial Default.
Detailed Description To avoid shutdown, system performance has been degraded. Recommended Response Action if unintended, review system configuration changes and power policy. Category System Health SubCategory PWR = Power Usage Severity Severity 2 (Warning) Trap/EventID 2274 LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory PWR = Power Usage Severity Severity 1 (Critical) Trap/EventID 2273 LCD Message System power exceeds capacity. System halted. Contact support Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE PWR1007 Message The system performance degraded because power exceeds capacity.
Trap/EventID 2273 LCD Message System power exceeds threshold. Performance degraded. Check PSU configuration Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE PWR1009 Message System power capacity restored. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2001 Message The system hard reset. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
PWR2003 Message User requested a PXE boot. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2006 Message The OS run-time software initiated a warm reset.
Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2200 Message The system is in the ON state. Detailed Description None Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2202 Message The system is sleeping with lost processor context. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2204 Message The system is in a non-volatile sleep state. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
PWR2207 Message The system is in a mechanical off state. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2210 Message The system was forced into a soft-off state.
Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2212 Message The system is in legacy OFF state. Detailed Description None Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE PWR3001 Detected new peak power value. Peak value (in Watts):arg1. Message Arguments • arg1 = peak value Detailed Description The system has detected a new peak power value.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2251 Message Power on permission error, chassis cover open. Detailed Description Host failed to power up because chassis cover is open. Recommended Response Action Check chassis cover.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2253 Message Power on permission error, no PCI/Mezz card installed in Fabric1/Fabric2 Detailed Description Host failed to power up because PCI/Mezz cards not installed in Fabric1/Fabric2. Recommended Response Action Install PCI/Mezz card in Fabric1/Fabric2.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE PWR2255 Message Power on permission error, CMC is in MPCM mode. Detailed Description Host failed to power up bacause CMC MPCM mode is enabled. Recommended Response Action Disable MPCM mode to power up.
PWR2401 Message Power management firmware initialization error Detailed Description The iDRAC controller detected that the power management firmware did not initialize properly. The system may operate in a performance degraded state. Recommended Response Action "1) Disconnect system input power, wait one minute, reconnect system input power. 2) Re-flash system BIOS. 3) Upgrade system BIOS to the latest revision.
Detailed Description The iDRAC controller established communication to the power management firmware. System performance returns to normal. Recommended Response Action No response action is required. Category System Health SubCategory PWR = Power Usage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
39 RAC Event Messages RAC0500 Message There are no batteries to be displayed. Detailed Description Batteries cannot be displayed. This error may occur if the host system is powered off or there is a bad or disconnected cable for batteries connected to the controller. Recommended Response Action 1. Check if the host system is powered off or shutdown. 2. Verify that the batteries are connected properly.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0502 Message There are no virtual disks to be displayed. Detailed Description Virtual disks cannot be displayed. This error may occur if the host system is powered off or there are no virtual disks created. Recommended Response Action 1. Check if the host system is powered off or shutdown. 2. Check if virtual disks are created.
RAC0504 Message There are no enclosures to be displayed. Detailed Description Enclosures cannot be displayed. This error may occur if the host system is powered off, there is no enclosure connected to the controller, or there is a bad or disconnected adapter cable for the enclosure. Recommended Response Action 1. Check if the host system is ON. 2. Check if the Storage Enclosure is ON. 3. Verify that the adapter cables are properly connected and there are no bent pins.
RAC0506 Message You do not have privileges to perform this operation. Detailed Description This error occurs when the user tries to access a program or function that is beyond user granted privileges. Recommended Response Action Contact the system administrator to perform the operation or grant the required privileges. Category Storage SubCategory RAC = RAC Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
RAC0508 Message An unexpected error occurred. Detailed Description The server encountered an unexpected condition. This may be due to invalid JavaScript Object Notation. Recommended Response Action Wait for few minutes and refresh the page. If the problem persists, contact service provider. Category Storage SubCategory RAC = RAC Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description This error occurs if Lifecycle log events have not occurred recently. Recommended Response Action No response action is required. Category Storage SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action 1. Check if the host system is ON. 2. Check if virtual disks are created. 3. Check if correct filters are applied. 4. Check if the Storage Enclosure is ON. 5. Verify that the adapter cables are properly connected and there are no bent pins. Category Storage SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0602 Message Invalid value for alert recurrence. Detailed Description The value for alert recurrence must be within the range 0-365. Recommended Response Action Enter a value between 0-365.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0604 Message System inventory may not be up-to-date because Collect System Inventory On Restart (CSIOR) is disabled.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0606 Message The network connection test operation was successful. Detailed Description The selected network connection test operation was successsful. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0608 Message The iDRAC will restart when the iDRAC firmware update is complete. All current user sessions will be closed. Detailed Description The message appears in Job Queue page when the iDRAC firmware update job status is downloading. Communication to the iDRAC will be lost when the iDRAC restarts to complete the firmware update.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0610 Message The passphrase and confirm passphrase values entered do not match. Detailed Description Different values were entered for passpharse and confirm passpharse field. Recommended Response Action Values entered in passphrase and confirm passphrase fields must be the same.
RAC0612 Message Cancelling the firmware update operation will delete all the uploaded firmware files. Do you want to continue? Detailed Description Cancelling the firmware update operation will cancel all firmware updates selected and delete all uploaded firmware files. Recommended Response Action Select Yes to cancel the firmware update operation and delete all uploaded firmware files. Select No to dismiss the message and continue the firmware update operation.
RAC0614 Message Incorrect password for PKCS#12 file. Detailed Description The specified password was incorrect for the PKCS#12 file. Recommended Response Action Make sure to use the correct password for the PKCS#12 file. If the PKCS#12 file is encrypted with a password, add it in required password box. Leave the password box empty if the file was not encrypted with a password.
RAC0616 Message Error while extracting custom signing certificate and private key from the PKCS#12 file. Detailed Description iDRAC was unable to continue with the operation after the PKCS#12 file was uploaded, because it is not able to extract the custom signing certificate and private key. Recommended Response Action Make sure to upload the PKCS#12 file that contains a valid custom signing certificate and private key.
Detailed Description The data entered caused an error while processing the request. Recommended Response Action Make sure to enter the correct data and retry the operation. Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Wait until Lifecycle Controller completes the current tasks and the system completes Poweron Self-test (POST). Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0560 Message RAC Software Initialization Error Detailed Description RAC Software Initialization error.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0101 Message The inserted Smart Card is not valid or the Smart Card reader is not supported. Detailed Description The data returned is not in a known format.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0103 Message This browser does not support Smart Card logon on iDRAC. Use Internet Explorer version 7.0 or later to use this feature. Detailed Description Smart Card login is only supported in newer versions of Internet Explorer.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0105 Message The Smart Card reader cannot be detected. Check whether the reader is installed correctly. Detailed Description Communication with the Smart Card reader cannot be established, or is lost. Recommended Response Action This error may occur because: 1. Check connection between reader and system. 2.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0107 Message The inserted Smart Card cannot be recognized. Ensure that the correct Smart Card CSP drivers are installed. Detailed Description Communication with the Smart Card reader is established and a Smart Card is inserted, but there are problems accessing the Smart Card.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0113 Message Remote Syslog Port value is invalid: Valid range is 1-65535 or 0x1-0xFFFF. Detailed Description Data entered is not an integer value in the valid range of numbers. Recommended Response Action Enter a Remote Syslog Port number.
RAC0116 Message Invalid Destination IPv6 Address. Detailed Description The entered IPv6 address does not conform to the addressing standard or the supported IPv6 address range. Recommended Response Action Enter a valid Destination IPv6 Address. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The SD card is not a valid vFlash SD card. The use of non-Dell media prevents the use of some extended capabilities and functions. Recommended Response Action Insert a supported vFlash SD card. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0124 Message Invalid label: Label must be exclusively alphanumeric characters. Detailed Description All characters in the label must be alphanumeric.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0127 Message The specified size must be a non-fractional numeric value. Detailed Description Size must be a whole number. Recommended Response Action Enter a whole number for the size field.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0129 Message An error has occurred while initializing the SD card. Detailed Description No status response was returned after completing the initialization request. Recommended Response Action Try reinitalizing the card again in a few minutes.
RAC0131 Message An error has occurred while deleting a partition. Detailed Description A seperate message will provide more detail about this error which was detected while deleting the vFlash partition. Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description A non-specific error has been detected when downloading the partition. Recommended Response Action Try downloading the partition again in a few minutes. If the problem persists, reset iDRAC before trying the operation again. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0136 Message An error has occurred while attaching a partition.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0138 Message A valid certificate is not loaded. Detailed Description The retrieved certificate came back as a null or empty document. Recommended Response Action Upload a valid certificate.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0141 Message Firmware update verification failed: The update status is unknown. Detailed Description Firmware update verification process failed; the firmware update status is unknown. Recommended Response Action Verify if the firmware has been updated by checking the new firmware version number.
RAC0146 Message Firmware rollback has failed. Detailed Description Firmware rollback operation failed. Recommended Response Action Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the operation. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description While the system is powered off it is unable to retrieve information about the batteries. Recommended Response Action Turn the system on to view this information. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0151 Message Unable to retrieve the removable flash media information. The system is powered off.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0153 Message Non-redundant power mode: Check the system hardware manual for implications. Detailed Description Power redundancy is typically used to protect equipment from unexpected power disruption that could cause data loss or hardware damage.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0155 Message Unable to retrieve the temperature information. The system is powered off. Detailed Description While the system is powered off it is unable to retrieve information about system temperature. Recommended Response Action Turn the system on to view this information.
RAC0158 Message Uploading kerberos keytab has failed. Detailed Description The Kerberos keytab is needed by the iDRAC to authenticate itself to the Kerberos (Active Directory) server. It is created on the AD server, and issued for the iDRAC. It?s like a password, and therefore should be kept secret. Recommended Response Action The Kerberos keytab file may be corrupt. Upload a valid Kerberos keytab file.
RAC0160 Message Certificate upload failed: Cannot validate the certificate. Detailed Description Certificate upload failed because the certificate could not be validated. Recommended Response Action Certificate may be corrupt. Try creating a new Certificate Signing Request (CSR) and then upload the certificate. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Certificate upload failed because the certificate has expired. Recommended Response Action Certificate has expired. Try creating a new Certificate Signing Request (CSR) and then upload the certificate. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Certificate upload failed because this is not a certificate file. Recommended Response Action Upload a valid certificate. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0209 Message Certificate upload failed: iDRAC unable to upload at this time. Detailed Description Certificate upload failed because iDRAC unable to upload at this time.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0212 Message Login failed. Verify that username and password is correct. Detailed Description This is a generic error message used on all the login pages. Recommended Response Action Enter valid credentials.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0214 Message Missing Password. Detailed Description Login page is missing a password. Recommended Response Action Enter a valid password. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
RAC0216 Message Login failed. Detailed Description Login failed because of an unknown reason. Recommended Response Action Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the operation. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description A maximum of 4 iDRAC Web GUI sessions can be open at any time. Recommended Response Action Close one or more sessions before opening another session. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0222 Message The Destination E-mail Address is invalid. Detailed Description The specified email address does not match an email address format. Ex: "janedoe@email.com.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0224 Message Invalid e-mail description. Detailed Description A partial string used to construct a complete error message. Recommended Response Action Enter a valid email description.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0226 Message Send Failed: Request processing failed. Detailed Description Sending the test mail failed. This will prevent alert messages from being sent to this email address. Recommended Response Action Confirm that: 1. A valid SMTP server address is configred in the iDRAC. 2.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0228 Message SD Card is detected with an unrecognized format. Click Initialize to initialize the card. Detailed Description SD Card needs to be formatted to make it usable. The card must be initialized. Recommended Response Action Click Initialize to initialize the card and make it usable.
RAC0231 Message This operation erases all data in the partition. Do you want to continue? Detailed Description This message is displayed when a confirmation is required to format the vFlash SD Card partition. Recommended Response Action Press OK to initialize this partition of the SD Card. This action will erase all the data in this partition. If undesired press Cancel.
Detailed Description vFlash image upload failed because the image is not valid. Recommended Response Action Image may be corrupt. Try uploading a valid vFlash image. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0239 Message SD Card is write-protected. Detailed Description The contents of a write protected SD Card cannot be modified.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0241 The specified size exceeds the maximum size ofarg1MB. Message Arguments • arg1 = size Detailed Description SD Card does not have enough free space available.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0243 Message Partition failed: A partitioning conflict has occurred with another session. Detailed Description There was a conflict with a concurrent session. Another user may have logged in using a separate browser or RACADM.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0245 Message The partition is in-use by another process. Detailed Description The vFlash partition is in-use by another process. Therefore, the current operation cannot proceed. Recommended Response Action Try the operation after a few minutes or with another partition. If the problem persists, reset iDRAC and repeat the operation.
RAC0247 Message The partition is currently attached. Detailed Description This message is displayed when trying to format or download to an attached vFlash partition. Recommended Response Action Detach this partition and try again. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The vFlash partition is in-use by another process. Therefore, the current operation cannot proceed. Recommended Response Action Try the operation after a few minutes. If the problem persists, reset iDRAC and repeat the operation. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0252 Message One or more partitions are currently detached. Detailed Description The vFlash partitions are detached Therefore, the current operation cannot proceed.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0254 Message The Gateway Address is invalid. Expected range: [0.0.0.0 or 1.0.0.0 - 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0256 Message The Preferred DNS Server Address is invalid. Expected range: [0.0.0.0 or 1.0.0.0 223.255.255.255 excluding: 127 (first octet), 0 or 255 (last octet)].
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0259 Message Invalid IPv6 address. Detailed Description This error message is displayed to indicate that the IPv6 address does not conform to the required format. Recommended Response Action Enter a valid IPv6 address.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0261 Message Invalid IPv6 gateway address. Detailed Description This error message is displayed to indicate that the IPv6 gateway address does not conform to the required format. Recommended Response Action Enter a valid IPv6 gateway address.
RAC0263 Message The Alternate IPv6 DNS Server Address is invalid. Detailed Description This error message is displayed to indicate that the Alternate IPv6 DNS Server address does not conform to the required format. Recommended Response Action Enter a valid Alternate IPv6 DNS server address. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Specify a valid VLAN ID. Recommended Response Action Enter a valid VLan ID. Expected range: 1-4094. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0267 Message Invalid VLAN Priority.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0269 Message The NIC MTU is invalid. Expected range: 576-1500 or 0x240-0x5DC. Detailed Description Specify a valid NIC MTU.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0271 Message Continuing will lock user account. Detailed Description Locking the user account prevents them from gaining access to iDRAC. Recommended Response Action Press OK to lock this user account.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0273 Message iDRAC access will be limited to running the Racadm utility on the local server or using the serial interface. Detailed Description If the the Enable NIC checkbox is cleared, remote access to iDRAC is disabled. Recommended Response Action Enable remote access to access iDRAC remotely.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0275 Message Click OK to disable the NIC. Click Cancel to keep the setting unchanged. Detailed Description If the the Enable NIC checkbox is cleared, remote access to iDRAC is disabled. Recommended Response Action Disable NIC only if remote access is undesired.
RAC0277 Message Disabling IPv4 prevents access to iDRAC using an IPv4 address. Detailed Description This warning message appears when IPv4 is disabled. Recommended Response Action Use IPv6 network to access iDRAC remotely. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description An invalid IPMI encryption key was entered. Recommended Response Action Enter a valid encryption key of up to 40 characters. Odd number of characters and blank spaces are not allowed. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0282 Message IP Blocking Fail Count is invalid. Expected range: 2-16.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0284 Message IP Blocking Fail Penalty Time is invalid. Expected range: 10-65535. Detailed Description This is the time span (in seconds) within which login attempts from an IP address with excessive failures are rejected.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0286 Message New Password and Confirm New Password fields cannot be empty. Detailed Description When creating a user account, the New Password and Confirm New Password fields cannot be empty. Recommended Response Action Enter valid passwords for New Password and Confirm New Password.
RAC0289 Message Values in New Password and Confirm New Password fields do not match. Detailed Description When creating a user account, the same value must be entered for New Password and Confirm New Password. Recommended Response Action Enter the same values for both New Password and Confirm New Password. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The user name value does not accept these characters. Recommended Response Action Do not enter /, \, @, ., or " (quotation mark) for user name. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Upload a valid root Certificate Authority (CA) certificate. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0294 Message The Character Accumulate Interval value is invalid.
Recommended Response Action Enter a valid Character Send Threshold value. Expected range: 1-255. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0297 Message Specify a Domain Controller Address must be configured.
SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0301 Message Remote File Share connection is unavailable. Check the settings and try again. Detailed Description User will be unable to connect to Remote File Share.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0303 Message Virtual Console is disabled or you do not have the Access Virtual Console privilege. Detailed Description This error message is displayed when Virtual Console feature is unavailable.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0801 Message iDRAC is being reset. Detailed Description iDRAC closes all the existing sessions and returns to the default static IP address.
RAC052 Message Unable to create a configuration job because an existing configuation job is already in progress. Detailed Description Unable to create a configuration job because an existing configuation job is already in progress. Only one configuration job for a component can run or can be processed at any time. Recommended Response Action Retry the operation after the existing configuration job is complete, or cancel the existing configuration job and retry the operation.
RAC055 Message User name cannot be cleared because the user account is enabled in the input configuration XML file. Detailed Description The user name for the user account cannot be cleared because the user account is enabled in the configuration XML file. Recommended Response Action Retry the operation after disabling the user account in the configuration XML file.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC057 Message Unable to set Privacy Protocol to an enabled state because the Authentication Protocol attribute is set to None for the user ID:arg1 Arguments • arg1 = user ID Detailed Description The Privacy Protocol for the user cannot be enabled because the Authentication protocol is disabled.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC059 Message Unable to configure time because Network Time Protocol (NTP) is enabled. Detailed Description When Network Time Protocol (NTP) feature is enabled, iDRAC will get time from NTP servers. Directly configuration of the iDRAC time is disabled with NTP is enabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0902 Message The -f option requires -d to also be specifed. Detailed Description The syntax of the specified command is invalid. In this case, the usage of the -f option is invalid. Recommended Response Action See the help text/documentation for the valid syntax of the subcommand.
RAC0904 Message The remote file location is not accessible or reachable. Detailed Description The iDRAC cannot access the remote file location. The credentials or path to the remote file location is incorrect or iDRAC cannot connect to the network address. Recommended Response Action Confirm that the path and credentials to remote file are correct, and check that the iDRAC can connect to the network address.
Detailed Description Unable to perform the requested operation. Recommended Response Action Try again later. If the problem persists, contact technical support. Refer to your product documentation to choose the contact method. Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0909 Message Invalid subcommand syntax: Specify the object name. Detailed Description The specified command is missing object name syntax.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0911 Message Data about version details is unavailable. Detailed Description Unable to retrieve version details. Recommended Response Action Try again later. If the problem persists, contact technical support.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC913 Message Unable to login to RAC using the specified address Detailed Description The management system could not login to the iDRAC. Recommended Response Action Verify whether the username and password given for the iDRAC are correct.
RAC915 Message 1000Mbps speed setting is Read Only and cannot be configured for the iDRAC NIC. Detailed Description Only possible configurations for the DRAC NIC are 10Mbps and 100 Mbps. For documentation with respect to this setting, refer to the racadm User Guide under cfgNetTuning group. Recommended Response Action No response action is required.
Detailed Description The syntax of the specified command is incorrect. Recommended Response Action See the command help text. To see the help text, run "racadm help ". Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC920 Message This interface does not support the specified option.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC922 Message Specified path is too long. Detailed Description The specified path (specified with the ?l parameter) for the remote share is too long. This path should be less than 256 characters in length.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC925 Message Recurrence interval is not applicable for this subcategory. Detailed Description An alert recurrence cannot be set for the specified subcategory. The alert recurrence is applicable only to the TMPS subcategory. Recommended Response Action 1. Check if the alert recurrence is applicable to this subcategory.
RAC927 Message Recurrence value modified successfully. Detailed Description The recurrence value was successfully modified to the specified value. Recommended Response Action None. Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The category or subcategory specified is incorrect. The recurrence interval is applicable only to the TMPS subcategory and system category. Recommended Response Action See the command help text, for a list of valid categories. Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC937 Successfully initiated configuration XML file import operation that was invoked by thearg1.
Recommended Response Action No response action is required. Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC939 Message Unable to start the system configuration profile export or import operation.
SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC941 Message Successfully initiated the export operation. This operation may take several minutes to complete.
SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC943 Message Warning: Collect System Inventory On Restart (CSIOR) feature is disabled. Detailed Description The Collect System Inventory On Restart (CSIOR) feature is currently disabled.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC945 Message Invalid object value specified. Detailed Description The dedicated NIC or shared NIC scan time value is not between 5 and 255 seconds.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC947 Message Invalid object value specified. Detailed Description The value used for the object set operation is invalid. Recommended Response Action Make sure to specify the value depending on the type of object. For more information, see RACADM help.
RAC949 Message Successfully added a work note to the Lifecycle Log. Detailed Description The specified work note was added to the Lifecycle Log. Recommended Response Action View the work notes using the ?racadm lclog view ?c worknotes? command. Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Up to 256 characters are allowed for a work note. Recommended Response Action Do not exceed 256 characters in the work note, and retry the operation. Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC954 Message The number of characters entered for the comment exceeds the supported limit. Detailed Description Up to 128 characters are allowed for a comment.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC956 Message There is no free space to add new comments to the Lifecycle Log. Detailed Description The allocated size for the Lifecycle Log entries has reached its maximum limit, and no further comments can be added to the Lifecycle Log.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC957 Message An import or export operation is currently in progress. Detailed Description Another import or export operation cannot be started until the current operation is complete. Recommended Response Action Wait until the current import or export operation is complete before starting another operation.
RAC959 Message Invalid file used for configuration XML file import operation. Detailed Description The content of the configuration XML file used for import is invalid because of incorrect modifications or content. Recommended Response Action Correct the modifications to the configuration XML file to be imported or specify the correct file, and retry the operation. Check the Lifecycle Log for more details.
RAC961 Message A pending or committed system configuration change exists. Detailed Description Another import operation cannot be started if an import operation that was performed earlier has some pending or commited configuration changes. Recommended Response Action Wait until the configuration changes are applied before starting another import operation. Use the ?racadm jobqueue view? command to check the status of the current import operation.
Detailed Description iDRAC is unable to read Lifecycle Controller status. Lifecycle Controller must be enabled to run the operation. Recommended Response Action Run the ?racadm get LifeCycleController.LCAttributes.LifecycleControllerState? command to get the status of the Lifecycle Controller. If the issue persists, contact your service provider. Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
Recommended Response Action Make sure to specify the location (-l) of the remote share along with the user name and password, and retry the operation. To view the list of options that can used for the required subcommand, use the ?racadm help ? command. Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action When using Firmware RACADM, make sure to export the configuration XML file to a remote share only. Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC970 Message Incorrect value specified for the end power state option.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC972 Message Insufficient privileges to run the configuration XML file import or export operations. Detailed Description Configuration XML import and export operations require the specified username to have administrator role privileges.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC974 Message Invalid wait time specified. Detailed Description The value specified for the wait time (?w) option is invalid. The valid range is 300 to 3600 seconds. Recommended Response Action Make sure to specify a valid wait time (-w) option and retry the command. The range of supported values are 300 to 3600 seconds.
RAC976 Message Export configuration XML file operation initiated. Detailed Description The configuration XML file export operation was initiated. Recommended Response Action Use the ?racadm jobqueue view ?i ? command to view the status of the operation. Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The Lifecycle Controller firmware version on the target system does not support the configuration XML file import or export operations. Recommended Response Action Update to the latest Lifecycle Controller firmware and retry the operation. Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC982 Message Invalid Public Key Cryptography Standards version 12 (PKCS12) file detected.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC984 Message Unable to upload the Public Key Cryptography Standards version 12 (PKCS12) file.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC986 Message The "vmkey" sub-command is deprecated. Detailed Description The "vmkey" sub-command is deprecated, and the functionality is available using "vflashsd" sub-command. Recommended Response Action Use "vflashsd" sub-command instead of "vmkey".
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC988 Unable to initiate thearg1firmware update. Message Arguments • arg1 = file name Detailed Description A new firmware update job cannot be initiated while an existing firmware update job is still in one of these states: "New", "Downloading", or "Running".
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC990 Unable to apply thearg1update. Message Arguments • arg1 = file name Detailed Description If Lifecycle Controller is disabled, the firmware update operation cannot continue.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC992 Invalid job:arg1. Message Arguments • arg1 = job ID Detailed Description The job ID specified in the message is invalid or was already deleted.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC994 Message Unable to run the "jobqueue delete --all" command. Detailed Description The jobs cannot be deleted if they are in one of these states: "Scheduled" or "Running".
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC1028 Message Unable to download the specified certificate type. Detailed Description The certificate cannot be downloaded if the certificate type specified is other than "1", "2", or "3".
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC1030 Message The custom signing certificate was deleted. Detailed Description The custom signing certificate present on iDRAC was deleted. Recommended Response Action No response action is required.
RAC1026 Message A custom signing certificate does not exist. Detailed Description A custom signing certificate must be present in the system to delete or downlod the certificate. Recommended Response Action No response action is required. Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The DHCP for Domian Name cannot be enabled if IPv4 and IPv4 DHCP or IPv6 and IPv6 AutoConfig is disabled. Recommended Response Action Make sure that IPv4 and IPv4 DHCP are enabled, or IPv6 and IPv6 AutoConfig are enabled Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC1000 Message Unable to set the object value for iDRAC IPv6 address or gateway.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC1002 Message Active Directory Single Sign On (SSO) cannot be enabled. Detailed Description The Active Directory SSO cannot be enabled, because the object SmartCardLogonEnable is enabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC1004 Message The smart card login cannot be enabled. Detailed Description The smart card login cannot be enabled, because the Active Directory Single Sign On is enabled. Recommended Response Action Disable Active Directory Single Sign On (SSO) using "racadm set iDRAC.ActiveDirectory.SSOEnable <0 | Disabled>", and retry the operation.
RAC1006 Unable to process thearg1, and the update was not applied. Message Arguments • arg1 = file name Detailed Description The update was not applied because of one of the following reasons: 1) The Update Package is invalid. 2) Lifecycle Controller is corrupted. 3) Another update is in progress. Recommended Response Action Do one of the following and retry the operation: 1) Dowload the correct Update Package from your service provider.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC1008 Message The Active Directory object DCLookupByUserDomain cannot be disabled. Detailed Description The Active Directory object DCLookupByUserDomain cannot be disabled, because the Active Directory object DCLookupDomainName is not configured.
RAC1010 Message Unable to set the power cap value. Detailed Description The power cap cannot be set if the object Power.Cap is disabled. Recommended Response Action Enable Power Cap setting using "racadm set System.Power.Cap.Enable < 1 | Enabled >", and retry the operation. Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Unable to change the auto-negotiation state for the current NIC selection mode, because the iDRAC NIC is in dedicated mode. Recommended Response Action Change the iDRAC NIC mode to shared mode using "racadm set idrac.nic.selection ", and retry the operation. Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action To configure the SNMPv3 Privacy Protocol for a specified iDRAC user, change the SNMPv3 Authentication Protocol to either MD5 or SHA state using "racadm set idrac.users..SNMPv3AuthenticationType ". Category Configuration SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC1018 Message The specified object or syntax is invalid.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC1020 Message No objects are available under the specified group for the current system configuration. Detailed Description Some objects have dependencies on other objects that are required to perform a task.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC1023 Message Unable to create the configuration job. Detailed Description Configuration jobs are created only if at least one object on the device or component (for example, NIC.Slot.1 or BIOS) has a pending value to be applied.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC1025 Message The specified object is read-only and cannot be modified due to an object dependency. Detailed Description Some objects have dependencies on other objects that are required to perform a task. However, some of the objects are read-only because of the current system configuration and the values of the dependent objects.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RAC0700 Email page successful toarg1. Message Arguments • arg1 = email address Detailed Description An email page was successfully sent. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0702 Message Requested system powercycle. Detailed Description Requested system powercycle. Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
RAC0704 Message Requested system powerdown. Detailed Description Requested system powerdown. Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Requested system NMI. Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0707 Message Primary Firmware image is invalid.
Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0709 Message Unknown server inserted into chassis.
SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0711 Message Unknown power on response from the CMC. Detailed Description Unknown power on response from the CMC. Recommended Response Action Try reseting the CMC.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0713 Message Server failed to power up due to fabric mismatch. Detailed Description Server failed to power up due to fabric mismatched.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0715 Message Image file does not exist in the given remote share path. Detailed Description Image file does not exist in the given remote share path. Recommended Response Action Ensure that the image file is available on the share path provided. Retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0717 Message Remote share unmounted successfully. Detailed Description Remote share unmounted successfully. Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
RAC0719 Message Not able to connect to remote file share. Virtual media devices are already in use. Detailed Description Not able to connect to remote file share. Virtual media devices are already in use. Recommended Response Action Stop existing Virtual Media sessions and retry the operation. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
RAC0721 Remote share mounted successfullyarg1. Message Arguments • arg1 = sharename Detailed Description Remote share mounted successfully. Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RAC0400 Message iDRAC memory low. Detailed Description iDRAC is running low on memory. Recommended Response Action No response action is required. Category Audit SubCategory RAC = RAC Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
40 RDU Event Messages RDU0001 Message The fans are redundant. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RDU = Redundancy Severity Severity 3 (Informational) Trap/EventID 2475 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE RDU0003 Message Fan redundancy is degraded. Detailed Description One of more fans have failed or have been removed or a configuration change occurred which requires additional fans. Recommended Response Action Remove and re-install failed fans or install additional fans.
RDU0005 Message The fans are not redundant. Insufficient resources to maintain normal operations. Detailed Description One of more fans have failed or have been removed or a configuration change occurred which requires additional fans. Recommended Response Action Remove and re-install failed fans or install additional fans. Category System Health SubCategory RDU = Redundancy Severity Severity 1 (Critical) Trap/EventID 2473 LCD Message No LCD message display defined. Initial Default.
Detailed Description The current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change. The system was previously operating in a power redundant mode. Recommended Response Action Check the event log for power supply failures. Review system configuration and power consumption.
Recommended Response Action If unintended, review system configuration and power consumption and install power supplies accordingly. Check power supply status for failures. Category System Health SubCategory RDU = Redundancy Severity Severity 3 (Informational) Trap/EventID 2475 LCD Message No LCD message display defined. Initial Default.
SubCategory RDU = Redundancy Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RDU0021 Message Unable to determine the redundancy status of the power supply units. Detailed Description One of the power supply units have failed.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RDU0023 Message Unable to determine the redundancy status of the fans. Detailed Description One or more fans are non-functional or may have failed. Recommended Response Action Check that all fans are working properly.
41 RED Event Messages RED000 Message Unrecognized error code encountered. Detailed Description An unknown error was returned. Recommended Response Action Check the uniform resource identifier (URI) target path and make sure the repository server is available. Category Updates SubCategory RED = FW Download Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED002 Message Package successfully downloaded. Detailed Description Package has been successfully downloaded. The Job Scheduler will schedule it at the time specified. Recommended Response Action Schedule the job if it is not already scheduled.
RED004 Message Job failed. Detailed Description The Job failed to execute due to an unknown error. Recommended Response Action Check the uniform resource identifier (URI), target path and make sure the repository server is available. Category Updates SubCategory RED = FW Download Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Dell Update Package download failed. Recommended Response Action Check the network connection and access to the update package from the system Category Updates SubCategory RED = FW Download Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Updates SubCategory RED = FW Download Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED009 Message Lifecycle Controller is not present. Detailed Description Lifecycle Controller is not present.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED011 Message USC version is not compatible. Detailed Description Current USC version does not support this component. Check InstanceID Recommended Response Action Use the latest version of USC available if possible.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED013 Message The DUP specified is not compatible with the target device. Detailed Description The DUP specified is not compatible with the target device. Recommended Response Action Download and use the DUP that matches the device being targeted.
RED015 Message The download protocol specified is not supported. Detailed Description The download protocol specified is not supported. Recommended Response Action The supported protocols include NFS, CIFS, HTTP, FTP, TFTP Category Updates SubCategory RED = FW Download Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The DUP specified is not compatible with the target system. Recommended Response Action Download and use the DUP that matches the system that the installation is targeting. Category Updates SubCategory RED = FW Download Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Directly update to the desired version. Category Updates SubCategory RED = FW Download Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED020 Message Feature not supported on current version of USC.
SubCategory RED = FW Download Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED027 Message Insufficient space to upload the requested file. Detailed Description The temporary storage is full. The uploaded files must be installed to clear space for additional uploads.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED029 Message A reboot is pending. Detailed Description This task will reboot the system at the scheduled start time. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RED031 Message Approaching maximum size limit allowed for storing firmware images. Detailed Description The internal space available for storing firmware images is almost full. Normal operations will continue until the critical limit is reached. When the critical limit is reached, all the rollback firmware images will be deleted.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RED033 Message Unable to reboot system. Detailed Description The request to shut down the operating system did not complete successfully. The iDRAC was unable to complete the system reboot. Any operation that depends on the system reboot will not complete until reboot is complete.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RED0101 Message Rollback successfull. Detailed Description The firmware was rolled back to the previous version. Recommended Response Action No response action is required. Category Updates SubCategory RED = FW Download Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
42 RFL Event Messages RFL2000 Internal Dual SD Modulearg1is present. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFL = IDSDM Media Severity Severity 3 (Informational) Trap/EventID 2211 LCD Message No LCD message display defined. Initial Default.
Trap/EventID 2210 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE RFL2003 Internal Dual SD Modulearg1is online. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID 2209 LCD Message Internal Dual SD Module failed. Check SD Card Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE RFL2005 Internal Dual SD Modulearg1is operating normally. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required.
SubCategory RFL = IDSDM Media Severity Severity 2 (Warning) Trap/EventID 2210 LCD Message Internal Dual SD Module is write protected. Check SD Card Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE TRUE RFL2007 Internal Dual SD Modulearg1is writable.
Category System Health SubCategory RFL = IDSDM Media Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE RFL2009 Internal Dual SD Modulearg1is enabled. Message Arguments • arg1 = name Detailed Description The Internal Dual SD Card redundancy feature was enabled.
43 RFLA Event Messages RFLA2001 Internal Dual SD Modulearg1is absent. Message Arguments • arg1 = name Detailed Description The SD card module is not detected or not installed. Recommended Response Action If unintended, reinstall the SD module. Category System Health SubCategory RFLA = IDSDM Absent Severity Severity 1 (Critical) Trap/EventID 2481 LCD Message Internal Dual SD Module is absent. Check SD card. Initial Default.
44 RFM Event Messages RFM1018 Message Removable Flash Media is absent. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RFM1020 Message Removable Flash Media is IPMI-function ready. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
RFM1022 Message Removable Flash Media is ready. Detailed Description None Recommended Response Action If unintended, reinstall the flash media. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description At boot, the Card Identification (CID) signature of the card is different from the Non-volatile (NV) storage value or the card is the destination of a copy operation that is in-progress. Recommended Response Action If unintended, reinstall the flash media. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory RFM = FlexAddress SD Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RFM1027 Message Removable Flash Media is operating normally. Detailed Description None Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RFM1029 Message Removable Flash Media was deactivated. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE RFM1031 Message Removable Flash Media has finished booting. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
RFM1033 Message Removable Flash Media is writable. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RFM = FlexAddress SD Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
45 RRDU Event Messages RRDU0001 Message Internal Dual SD Module is redundant. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory RRDU = IDSDM Redundancy Severity Severity 3 (Informational) Trap/EventID 2491 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE RRDU0003 Message Internal Dual SD Module redundancy is degraded. Detailed Description Either one of the SD card or both the SD cards are not functioning properly. Recommended Response Action Replace the failed SD card.
RRDU0005 Message Internal Dual SD Module is not redundant. Insufficient resources to maintain normal operations. Detailed Description The current operating configuration cannot maintain redundancy.The unit may operate in a degraded state. Recommended Response Action Review product documentation and SD card configuration. Category System Health SubCategory RRDU = IDSDM Redundancy Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message Internal Dual SD Module is not redundant.
RRDU0011 Message Unable to determine the redundancy status of the Internal SD Module. Detailed Description This occurs because of one of the following reasons: 1) Either one of the SD card or both the SD cards have failed. 2) The Internal SD Module has failed. Recommended Response Action Replace the failed SD card with a new SD card, or replace the Internal SD Module. For more information, contact your service provider.
46 RSI Event Messages RSI0001 Message The Lifecycle Controller Remote Services is available. Detailed Description The Lifecycle Controller Remote Services instrumentation is available Recommended Response Action No response action is required. Category Configuration SubCategory RSI = Remote Service Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE RSI0003 Message The remote service is reloading data Detailed Description The Remote Service database is being updated Recommended Response Action Retry request later Category Configuration SubCategory RSI = Remote Service Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
47 SEC Event Messages SEC0000 Message The chassis is open. Detailed Description The chassis is open. System performance may be degraded, and security may be compromised. Recommended Response Action Close the chassis. Check system logs. Category System Health SubCategory SEC = Security Event Severity Severity 1 (Critical) Trap/EventID 2385 LCD Message Intrusion detected. Check chassis cover Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEC0002 Message The I/O card area is open. Detailed Description The I/O card area is open. I/O cards may be added or removed. System performance may be degraded. Recommended Response Action Close the I/O card area. Check system logs.
SEC0004 Message The LAN is disconnected. Detailed Description The LAN is disconnected. Network performance may be degraded. Recommended Response Action If unintentional, connect network cable. Category System Health SubCategory SEC = Security Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The fan area is open. System performance may be degraded. Recommended Response Action Close the fan area. Check system logs. Category System Health SubCategory SEC = Security Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory SEC = Security Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEC0018 Message The I/O card area is closed. Detailed Description None Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEC0020 Message The LAN is connected. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEC0022 Message The fan area is closed. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEC = Security Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SEC0032 Message The chassis is closed while the power is on. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEC = Security Event Severity Severity 3 (Informational) Trap/EventID 2387 LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEC = Security Event Severity Severity 3 (Informational) Trap/EventID 2387 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE SEC0040 Message A critical stop occurred during OS load.
Category System Health SubCategory SEC = Security Event Severity Severity 1 (Critical) Trap/EventID 2385 LCD Message BIOS detected an error configuring TXT. Check system configuration. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE SEC0042 Message Processor detected an error while performing an Intel Trusted Execution Technology (TXT) operation.
Severity Severity 1 (Critical) Trap/EventID 2385 LCD Message BIOS detected a TXT error during POST. Check system configuration. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE SEC0044 Message SINIT Authenticated Code Module detected an Intel Trusted Execution Technology (TXT) error at boot. Detailed Description TXT initialization failure.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE SEC0600 Message A secure mode violation detected. Detailed Description This may apply to a physical or remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEC0602 Message User password violation detected. Detailed Description This may apply to a physical or remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies.
SEC0604 Message A setup password violation detected. Detailed Description This may apply to a physical or remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies. Category System Health SubCategory SEC = Security Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description This may apply to a physical or remote access attempt. Recommended Response Action Check system logs for intrusion attempts, and ensure strong password policies. Category System Health SubCategory SEC = Security Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory SEC = Security Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEC0609 Message A password violation was corrected. Detailed Description None Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEC0611 Message An Out-of-band password violation was corrected. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SEC0052 Message Chassis intrusion sensor may have failed. Detailed Description The chassis intrusion sensor may have failed, because of this it cannot be determined whether the chassis is closed or opened. This condition can lead to degraded system performance because of insufficient cooling. The system security may be compromised.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE SEC0701 Message Warning: Default username and password are currently in use. It is strongly recommended to change the default password immediately. Detailed Description This warning message is displayed when using the default username and password (root and calvin).
48 SEL Event Messages SEL0002 Message Logging is disabled. Detailed Description This message appears when event logging of a specific type is disabled by the user. (IPMI sensor type code 10h - offset 01h) Recommended Response Action If unintended, re-enable logging. Category System Health SubCategory SEL = Sys Event Log Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL0004 Message Log cleared. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) Trap/EventID 2379 LCD Message No LCD message display defined. Initial Default.
SEL0007 Message All event logging is enabled. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SEL0010 Message System event log (SEL) is almost full. Detailed Description When the event log is full, additional events are not written to the log or older events will be overwritten and lost. (IPMI sensor type code 10h - offset 05h) Recommended Response Action Backup and clear log at the next maintained time. Category System Health SubCategory SEL = Sys Event Log Severity Severity 2 (Warning) Trap/EventID 2378 LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1200 Message The system was reconfigured.
Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1204 Message An unknown system hardware failure detected. Detailed Description The operating system or BIOS detected an unknown event.
Trap/EventID 2379 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE SEL1206 Message An entry was added to auxiliary log. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1208 Message A platform event filter action was executed. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SEL1210 Message The time-stamp clock is synchronized. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description System setup displays the system boot order. The local video screen may also show additional information. (IPMI sensor type code 1eh - offset 00h) Recommended Response Action Check system boot settings. Check mass storage controller configuration settings is applicable. Category System Health SubCategory SEL = Sys Event Log Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory SEL = Sys Event Log Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1303 Message Bootable diskette detected. Detailed Description None Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1305 Message The PXE server found. Detailed Description None Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1307 Message Boot sector found. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SEL1309 Message User selected a boot source. Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1404 Message A platform event trap (PET) was generated.
Category System Health SubCategory SEL = Sys Event Log Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1500 Message The chassis management controller (CMC) is redundant. Detailed Description None Recommended Response Action No response action is required.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1502 Message Chassis management controller (CMC) redundancy is degraded. Detailed Description An action or failure has taken place that degrades CMC redundancy.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1504 Message The chassis management controller (CMC) is not redundant. Insufficient resources to maintain normal operations. Detailed Description There is not enough available power for two CMCs to operate. Recommended Response Action Check overall power consumption and power status.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1507 Communications restored with Chassis Group Memberarg1. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1509 Memberarg1has joined the Chassis Group. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL1511 Memberarg1removed from the Chassis Group. Message Arguments • arg1 = number Detailed Description None Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SEL9901 Message OEM software event. Detailed Description The current software version cannot decode this event.
LCD Message No LCD message display defined. Initial Default.
49 SSD Event Messages SSD1001 Write-cache onarg1is enabled. Message Arguments • arg1 = PCIe SSD name Detailed Description Write-cache is enabled on the PCIe solid state drive (SSD) identified in the message. Recommended Response Action No response action is required. Category Storage SubCategory SSD = PCIe SSD Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SSD1003 arg1is ready for removal. Message Arguments • arg1 = PCIe SSD name Detailed Description The PCIe solid state drive (SSD) identified in the message is ready for removal.
Category Storage SubCategory SSD = PCIe SSD Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SSD1005 Successfully initializedarg1.
Detailed Description The PCIe solid state device identified in the message is approaching the warranted wear-out limit. Recommended Response Action No response action is required. Category Storage SubCategory SSD = PCIe SSD Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = PCIe solid state device name Detailed Description The PCIe solid state device identified in the message is between 90% and 100% of reaching read-only mode. Recommended Response Action No response action is required. Category Storage SubCategory SSD = PCIe SSD Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SSD1010 Thearg1is in a security locked state. Message Arguments • arg1 = PCIe solid state device name Detailed Description The PCIe solid state device identified in the message is in a locked state, because an existing initialization task was interrupted due to a power failure or disk removal. Recommended Response Action Run Full Initialize operation on the device identified in the message.
50 STOR Event Messages STOR1 A devicearg1is in an unknown state. Message Arguments • arg1 = device name Detailed Description The controller cannot communicate with a device. The state of the device cannot be determined. There may be a bad or loose cable, or a missing device, or a problem with the driver or firmware. Recommended Response Action See the storage hardware documentation for information on checking the cables. Check for problems with any enclosures attached to the system.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR3 CEM Storage Management has lost communication with thearg1. Message Arguments • arg1 = Controller Name Detailed Description Storage Management has lost communication with a controller.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR5 Redundancy lost.arg1 Message Arguments • arg1 = VD/Enclosure Name Detailed Description A virtual disk or enclosure has lost data redundancy.
Detailed Description A comparison of storage inventory collected before and after the host re-boot/re-set. reports differences. There could have been some storage components added or removed when the host was powered down. Recommended Response Action No response action is required. Category Storage SubCategory STOR = Storage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description High Availability RAID is not supported by this firmware release. This event may occur during the upgrade process. Recommended Response Action Remove one RAID controller. Category Storage SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR007 Message Resource Allocation Failure. Detailed Description Command failed due to lack of memory or file space. Recommended Response Action Reset iDRAC and run the command.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR010 Message RAID level not supported on controller Detailed Description RAID level provided not valid for this controller Recommended Response Action Provide a valid RAID level Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined.
STOR012 Message Provided Physical disk not valid for this operation Detailed Description One or more of provided physical disks cannot be used. Recommended Response Action Check the RAID profile for correct status and use of provided physical disk(s) Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Hit maximum limit for virtual disks on the controller Recommended Response Action A new virtual disk cannot be created until one is deleted. Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR018 Message No foreign drives detected Detailed Description This operation did not detect any foreign drives.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR020 Message Controller Key is already present Detailed Description Controller key cannot be set because the key is already present. Recommended Response Action Controller already has a key. Key must be deleted to key the controller again.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR022 Message Controller is not security capable Detailed Description Controller does not have the capability to secure virtual disks Recommended Response Action Controller does not have security capability.
STOR024 Message Configuration already committed, cannot commit until previous commit succeeds or is cancelled Detailed Description Configuration changes are already scheduled Recommended Response Action Configuration is already scheduled. No need to schedule again. Category Configuration SubCategory STOR = Storage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
STOR026 Message Configuration Job not Created, there are no pending Configuration changes Detailed Description There are no pending configuration changes for this device, the job cant be created. Recommended Response Action There were no pending configuration changes found; the configuration job cannot be created when there are pending configuration changes.
Detailed Description Could not find the provided virtual disk Recommended Response Action Provide a valid virtual disk FQDD. Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR031 Message Lifecycle Controller is not enabled. Detailed Description For 11G systems: System Services must be enabled to perform the requested operation.
Recommended Response Action Wait for current Lifecycle Controller operation to complete. Verify that the system is 1) Not currently in Lifecycle Controller Unified Server Configurator 2) Not waiting for user intervention at F1/F2 POST error 3) Not in any of the device or controller Option ROMs and retry the operation. Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Provide a valid parameter value for specifed parameter Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Provide valid attribute Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The attribute value is not supported in the current configuration Recommended Response Action Provide a settable value for the specifed attribute by refering the possible values for that attribute Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR047 AttributeValue cannot be changed for ReadOnly Attribute Namearg1 Message Arguments • arg1 = attribute Detailed Description AttributeValue cannot be changed for ReadOnly Attribute Name Recommended Response Action Cannot change this attribute.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR049 Message Controller is in Local Key Management mode Detailed Description Controller is in Local Key Management mode Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR051 Message StartingLBA and Size combination goes beyond Physical Disk size Detailed Description The starting LBA and size parameters are incorrect Recommended Response Action Refer to the users guide to provide the correct StartingLBA and Size combination Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning)
STOR053 Message Controller key not present, controller needs key from Dell Key Management Server Detailed Description System could not obtain key from the Dell Key Management Server Recommended Response Action Refer to the DKM documentation for setting the Key management server. Category Configuration SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description There are no Virtual Disk on the controller so the operation cannot be performed. Recommended Response Action Create a Virtual Disk before invoking this operation. Category Configuration SubCategory STOR = Storage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory STOR = Storage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR062 Message One or more Physical Disks specified are full and cannot be used to create additional Virtual Disks.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR0201 Message Unable to determine whether the system has the minimum required versions of the RAID controller drivers and firmware.
Recommended Response Action Reinstall Server Administrator and Storage Services. Category Storage SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action See the Readme file for the driver requirements and update the system to meet the minimum requirements and reinstall Storage Services. Category Storage SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Storage SubCategory STOR = Storage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR0207 Message Smart thermal shutdown feature is disabled.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR0209 Message Unable to monitor or manage SAS components because the initialization sequence of the devices did not complete.
Category Storage SubCategory STOR = Storage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR0211 Thearg1has returned to normal state.
Detailed Description The device (physical disk or an enclosure) identified in the message has failed. The device (physical disk or an enclosure) failure was detected while performing a rescan. However, physical disk failures are also detected during a check consistency operation. Recommended Response Action Replace the identified device. A failed device is inidicated with a red color "X" status icon. Perform a rescan after replacing the failed device.
Detailed Description No RAID controller is installed on the system. Recommended Response Action Install the RAID controller and do the following: 1) Reboot the system. 2) Press the key to re-enter Lifecycle Controller. 3) Retry RAID configuration. Category Storage SubCategory STOR = Storage Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Storage SubCategory STOR = Storage Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE STOR0505 Message Unable to delete virtual disks. Detailed Description Unable to delete the existing virtual disks for unknown reasons.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE STOR0507 Message Insufficient physical disk space on selected RAID controller.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE STOR0509 Message No RAID levels are supported. Detailed Description The controller does not have the minimum number of initialized disks to create a virtual disk.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE STOR0511 Message Unable to change the encryption key. Detailed Description Unable to change the encryption key due to an internal error. Recommended Response Action Exit Lifecycle Controller, press the key to re-enter Lifecycle Controller, and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE STOR0513 Message Unable to encrypt virtual disks. Detailed Description Unable to encrypt unsecure virtual disks due to an internal error. Recommended Response Action Exit Lifecycle Controller, press the key to re-enter Lifecycle Controller, and retry the operation.
STOR0102 Message No batteries are displayed. Detailed Description No battery data to display. The system is powered off, batteries are not present on the system, batteries are not connected to the RAID controller, or the batteries are depleted. Recommended Response Action Check if the server has power, batteries are available, and batteries are connected to the RAID controller.
Detailed Description No virtual disk data to display. The system is powered off, physical disks are not present on the system, or virtual disks are not created. Recommended Response Action Check if the server has power, physical disks are available, and virtual disks are created. Category Storage SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Storage SubCategory STOR = Storage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR0107 Message EMMs are not connected to enclosures or data about EMMs is unavailable. Detailed Description No EMMs data to display.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR0109 Message Power supply unit is not connected to the enclosure or data about power supply unit is unavailable. Detailed Description No power supply unit data to display.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE STOR0111 Message Invalid reference key. Detailed Description The specified reference key is invalid. Recommended Response Action Verify that the correct reference key is specified. See the help text or documentation for valid reference keys.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE 1096 FALSE FALSE
51 SUP Event Messages SUP001 Message Insufficient parameters provided. Detailed Description Insufficient Parameters provided for the WSMAN command. Recommended Response Action Make sure the parameters are correct and in the right number and format and retry the action. Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP003 Message Invalid URI, target or reboot flag. Detailed Description One of the uniform resource input (URI) string, target or reboot flag parameters is missing or exceeds the prescribed length.
SUP006 Message Update package downloading - Delete failed. Detailed Description The DUP is being downloaded and the update cannot be deleted while the download is in progress Recommended Response Action Wait until the update package is downloaded and retry the action. The download can take more than 5 minutes depending on network speed and size of the update package.
Detailed Description Because of the size of the driver pack, the update process removes the older version of the driver pack from the system before installing the newer version. For that reason, the driver pack update cannot be deleted. Recommended Response Action Wait for the Driver Pack update to complete. To revert to the previous version of the update, download and update the firmware to the version desired.
Recommended Response Action Do not try to delete the job when the update process is underway. To revert to the previous version of the update, download and update the firmware to the version desired or run the rollback command to go back to the previous version. Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SubCategory SUP = FW Update Job Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP016 Message Job cannot be scheduled. Detailed Description Only jobs with the job status of Downloading / Downloaded / Pending Reboot can be scheduled.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP018 Message Invalid until time. Detailed Description The specified until time is invalid. Recommended Response Action Until Time should be in the form YYYYMMDDHHMMSS. Verify the specified until time and retry the action.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP020 Message The specified job was deleted Detailed Description The specified job was successfully deleted from the job queue. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP022 Message Job store has reached the maximum storage limit. Detailed Description JobStore file has exceeded the size limit. Delete all unneeded JobIDs from the job store. \n \n Recommended Response Action New JobId cannot be stored. Manually delete the failed jobs and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP025 Message The command was successful Detailed Description Generic message to show that last command was successful. Recommended Response Action Informational Message. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0502 Message Unable to collect system inventory. Detailed Description iDRAC is unable generate the inventory file or the inventory file received from iDRAC is faulty. For more information about the failure, see Lifecycle Log. Recommended Response Action Retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0504 Message Unable to authenticate the catalog file in the update repository. Detailed Description The catalog file in the update repository is not digitally signed. Recommended Response Action Use a repository that has the catalog file from a trusted source and retry the operation.
SUP0506 Message Unable to decompress the catalog file. Detailed Description The catalog file in the selected repository is corrupt or compressed in an unsupported format. Recommended Response Action Select a repository with a valid catalog file, and retry the operation. Category Updates SubCategory SUP = FW Update Job Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The Diagnostic application (Embedded Preboot System Assessment - Enterprise UEFI Diagnostics) is not installed or is corrupt. Recommended Response Action Update the Diagnostics application using the Firmware Update feature in Lifecycle Controller. For the latest Update Packages, contact your service provider. Category Updates SubCategory SUP = FW Update Job Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Updates SubCategory SUP = FW Update Job Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0515 Message Unable to authenticate the Update Package signature.
Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0517 Unable to update thearg1firmware to versionarg2.
Detailed Description The specified firmware for the component was successfully updated. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
• arg2 = version Detailed Description The firmware update operation for the component did not complete due to an internal error. Recommended Response Action Retry the operation. If the problem persists, download the latest Update Package from your service provider and retry the operation. Category Updates SubCategory SUP = FW Update Job Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Download the latest Update Package from your service provider and retry the operation. Category Updates SubCategory SUP = FW Update Job Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0526 Message Unable to continue with firmware update.
SubCategory SUP = FW Update Job Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0528 Message Unable to generate a firmware comparison table. Detailed Description An internal error occurred in the Lifecycle Controller while generating the firmware comparison report.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0530 Message Incorrect repository path location. Detailed Description The catalog repository path entered is not accessible. Recommended Response Action Retry the operation with the correct catalog repository path.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP0532 Message The repository contains corrupt Update Packages. Detailed Description The repository contains corrupt Update Packages. Recommended Response Action Enter another repository location that contains the desired Update Packages and retry the operation.
SUP0534 Message Unable to locate the catalog file. Detailed Description The catalog file cannot be found in the specified location. Recommended Response Action Specify the correct repository location and retry the operation. Category Updates SubCategory SUP = FW Update Job Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SUP0536 Successfully updatedarg1. Message Arguments • arg1 = component and version Detailed Description Component firmware update was successful. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SUP0538 Unable to updatearg1. Message Arguments • arg1 = component and version Detailed Description Unable to update firmware due to one the following: 1) Update Package is not supported. 2) Trusted Platform Module feature is enabled in BIOS settings. Recommended Response Action Retry the operation. If the problem persists, do one of the following and retry the operation: 1) Download the latest Update Package from your service provider. 2) Disable the Trusted Platform Module feature in BIOS settings.
SUP0100 Message Firmware update operation failed. Detailed Description The firmware update operation failed. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The TFTP IP Address specified is invalid. Recommended Response Action Specify a valid TFTP IP Address. Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0105 Message Invalid firmware image Detailed Description The firmware image provided by the user is not valid.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0107 Message File path too long. Detailed Description The file path provided as a parameter is too long. Recommended Response Action Shorten the length of the string given as file path by either moving the file or renaming the folders along the path.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0109 Message A TFTP IP address has not been specified but is required. Detailed Description The firmware update cannot proceed without the TFTP IP address. Recommended Response Action Specify the TFTP IP address.
SUP0111 Message Timeout waiting for firmware update process to complete. Detailed Description Firmware Update time-out occurred. Recommended Response Action Re-try the firmware update process. Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SUP0113 Message TFTP firmware update is currently disabled. Detailed Description The cfgRhostsFwUpdateTftpEnable object must be set. Recommended Response Action Set the cfgRhostsFwUpdateTftpEnable object in cfgRemoteHosts group using config subcommand. Category Updates SubCategory SUP = FW Update Job Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The rac cannot be reset, while the firmware update is in progress. Recommended Response Action Wait for the firmware update to finish. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0118 Message iDRAC reset failed.
SubCategory SUP = FW Update Job Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0120 Message Preparing for firmware update. Please wait... Detailed Description Success message. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0122 Message Firmware update completed successfully Detailed Description Success message. Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0124 Message Firmware update is not currently in progress Detailed Description Success message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0126 Message Firmware update in progress. Please wait... Detailed Description Success message. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SUP0128 Message Ready for firmware update Detailed Description Success message. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Success message. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SUP0131 Message FTP firmware update has been initiated.
Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP1902 Message Firmware update stopping services.
SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP1904 Message Firmware update checksumming image. Detailed Description Firmware update checksumming image. Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP1906 Message Firmware update successful. Detailed Description Firmware update successful. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SUP1908 Message Firmware update failed checksum. Detailed Description Firmware update failed checksum. Recommended Response Action Reacquire the image from the original source and retry the operation.
SUP1910 Message Firmware update is not pending. Detailed Description Firmware update is not pending. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Firmware update RAC recover successful. Recommended Response Action No response action is required. Category Updates SubCategory SUP = FW Update Job Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
52 SWC Event Messages SWC4004 A firmware or software incompatibility detected between iDRAC in slotarg1and CMC. Message Arguments • arg1 = number Detailed Description FlexAddress is not implemented in one of the versions of firmware. Please update the firmware. Recommended Response Action Check firmware versions of iDRAC and CMC. Update to latest version.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC4006 A firmware or software incompatibility detected between system BIOS in slotarg1and CMC. Message Arguments • arg1 = number Detailed Description FlexAddress is not implemented in one of the versions of firmware. Please update the firmware.
SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC4008 Message A firmware or software incompatibility detected between CMC 1 and CMC 2. Detailed Description FlexAddress is not implemented in one of the versions of firmware.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC5000 arg1upgrade was successful. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC5002 arg1upgrade was successful but encountered minor errors. Message Arguments • arg1 = name Detailed Description None Recommended Response Action Check system logs for minor errors.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0701 Message Power capping is enabled. Detailed Description Power capping is enabled and sets user-defined power capping limits for the system. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0717 Message iDRAC Local Configuration is disabled. iDRAC Settings are accessed in read-only mode. Detailed Description For security reasons, the local configuration is disabled. Enable local configuration from the iDRAC Web interface Recommended Response Action Enable iDRAC local configuration from iDRAC Web interface.
SWC0723 Message Error occurred while Resetting to defaults. The Reset status is not available. Detailed Description iDRAC is not responding to the current Reset status query. Recommended Response Action Retry after a few minutes. Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description iDRAC7 is busy and does not respond to iDRAC7 configurator IPMI requests. Recommended Response Action Try AC power cycling the server or upgrade the iDRAC firmware. Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Retry the operation. If the problem persists: 1) Turn off the system and disconnect the power cord. 2) Wait for five seconds. 3) Reconnect the power cord, turn on the system, and retry the operation. Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0005 Message Unable to display the current hardware inventory.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0007 Message Unable to write the current hardware inventory to the specified destination.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0011 Message Successfully applied front panel security settings. Detailed Description The front panel security settings were successfully configured. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0013 Message Unable to save the front panel security settings. Detailed Description The oepration to save the front panel security settings encountered an unexpected error while communicating with iDRAC. Recommended Response Action Retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0015 Message Unable to retrieve the list of supported operating systems. Detailed Description The operating system driver pack is missing or not accessible. Recommended Response Action Update the system with the latest Lifecycle Controller OS Driver Pack. Obtain the OS Driver Pack from the service provider.
SWC0017 Message Unable to retrieve the drivers for the selected operating system. Detailed Description An unrecoverable error occurred while retireving the drivers. Recommended Response Action Exit the OS Deployment wizard and retry the operation. If the problem persists, exit Lifecycle Controller and perform an AC power cycle. Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined.
Detailed Description The Test Network Connection ping test timed-out. The network cable is disconnected or the network is not configured correctly. Recommended Response Action Check the network cable connection and network configuration settings, then retry the operation. If the problem persists, reconfigure the network settings and retry the operation.
Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0062 Message Unable to export Lifecycle Log. Detailed Description The destination folder is not present, the destination is full or write-protected.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0024 Message The Test Network Connection ping test timed-out. Detailed Description The Test Network Connection ping test timed-out. The network cable is disconnected or the network is not configured correctly.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0026 Message Unable to retrieve status of backup Server Profile operation. Detailed Description Status of backup Server Profile operation could not be retrieved because an unrecoverable error occurred while communicating with iDRAC.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0028 Message The backup Server Profile operation did not successfully complete. Detailed Description iDRAC is unable to complete the backup Server Profile operation because an unrecoverable error occurred. Recommended Response Action Reset iDRAC and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0065 Message Unable to retrieve the drivers for the selected operating system. Detailed Description Lifecycle Controller is unable to copy the OS drivers from the OS driver pack. Recommended Response Action Exit the OS Deployment wizard and retry the operation.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0031 Message Unable to initiate the backup Server Profile backup operation. Detailed Description iDRAC is unable to initiate the backup Server Profile operation because an unrecoverable error occurred. Recommended Response Action Reset iDRAC and retry the operation.
SWC0033 Message Successfully exported the Server Configuration Profile image file to network share. Detailed Description Exporting the Server Configuration Profile image file to the network share was successful. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SWC0035 Message Unable to initialize backup Server Profile operation. Detailed Description The backup operation did not initialize because the system does not have a service tag. Recommended Response Action Assign a service tag to the system and retry the operation. To assign the service tag, contact your service provider. Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SWC0037 Message Unable to export the file to the network share. Detailed Description Lifecycle Controller is unable to export the file to the network share because the destination folder is not present or inaccessible. Recommended Response Action Make sure that the destination folder is present and accessible, then retry the operation. If the problem persists, check network settings and retry the operation.
Detailed Description The backup Server Configuration Profile image partition is not present in the vFlash SD card. Recommended Response Action A backup Server Configuration Profile is required to import or export a Server Profile. Perform the backup operation and retry import or export operation. Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0042 Message Unable to retrieve the status of the Import Server Profile operation.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0044 Message Unable to retrieve the status of the Import Server Profile operation. Detailed Description Lifecycle Controller is unable to retrieve the status of the Import Server Profile operation.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0046 Message Unable to initiate Import operation. Detailed Description Unable to initiate Import operation since another Import operation is already in progress.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0048 Message Unable to validate the backup server configuration Profile image file for this system. Detailed Description The backup server profile operation did not complete because: 1) The backup server configuration profile image file present on the vFlash SD card is invalid for this system.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0050 Message Unable to initiate Import operation. Detailed Description Unable to initiate Import operation since iDRAC is not responding. Recommended Response Action Retry the Import operation using a valid backup image file and the correct passphrase.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0052 Message Unable to continue with OS Deployment operation. Detailed Description An error occurred while retrieving the operating system drivers. Recommended Response Action Exit the OS Deployment wizard and update the system with the latest operating system driver packs available from the service provider and retry the operation.
SWC0054 Message Unable to save settings. Detailed Description There was an internal error while saving the settings. Recommended Response Action Retry the operation. If the problem persists, reboot the system or update the Lifecycle Controller firmware to the latest version and retry the operation. Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Unable to export the file to the USB drive because it does not have the specified folder, does not have enough free space, or is read-only. Recommended Response Action Make sure that the USB drive contains the folder specified, has enough free space, or is not read-only. If the problem persists, reboot the system and retry the operation.
Recommended Response Action Make sure that the network share has sufficient free space then retry the operation. If the problem persists, check network settings and retry the operation. Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0060 Message Unable to complete the operation. Detailed Description One or more vFlash partitions are attached.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC0247 Message Invalid subcommand specified. Detailed Description An invalid subcommand was entered. Recommended Response Action Refer the list of subcommands.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0249 Invalid syntax. The requestsed subcommand requires -iarg1to\nbe specified. Message Arguments • arg1 = index Detailed Description The specified parameter needs to be given with its legal value. Recommended Response Action Enter the proper index preceeded by -i.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0251 Invalid index value. Only index valuesarg1-arg2are permitted. Message Arguments • • arg1 = number arg2 = number Detailed Description The value of specified parameter is invalid. Recommended Response Action Enter the index value as specified by the message.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0253 Message Unable to allocate memory needed to perform operation. Detailed Description Unable to allocate memory to perform the operation, see the inserted comment. Recommended Response Action Power Cycle the system and re-enter the command.
SWC0255 Message Unable to open file. Detailed Description Unable to open the specified file. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Invalid number of arguments were passed to the command. Recommended Response Action Refer the help text for the command. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0260 Message Invalid object specified. Detailed Description The value of specified parameter is invalid.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0262 Message Unable to perform operation. Please make sure RAC controller and \nappropriate IPMI drivers are installed. Detailed Description The IPMI drivers or the RAC contorller may not be installed.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0264 Message Resource currently in use by another process. Please retry again later. Detailed Description The resources required for the execution are in use by another process Recommended Response Action Wait for the process to release the resources and try again.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0266 Message Unable to perform the requested operation. Make sure SD card is inserted. Detailed Description The SD card may not be inserted/inserted properly. Recommended Response Action Ensure that the SD card is inserted in the server.
SWC0268 Message There is no ASR screen currently available to clear Detailed Description The ASR screen is already cleared. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SWC0270 Message Unable to clear the SEL. \nPossible reason may be that Local Configuration using RACADM is disabled. Detailed Description Local Configuration using RACADM may be disabled. Recommended Response Action Check if the Local Configuration using RACADM is disabled and enable it through GUI. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SWC0272 Message Invalid syntax. The -g option is only valid with -o, -i, and -c. Detailed Description The syntax for the config command is invalid. Recommended Response Action Refer to the help text for the config subcommand. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The value of specified parameter is invalid. Recommended Response Action Enter the same command with a legal value to the object. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0277 Message Invalid syntax. The -i option is only valid with -g and -o. Detailed Description The syntax for the config command is invalid.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0279 Message The specified group is not indexed and does not support -i. Detailed Description The group is not indexed and does not require an index to be specified. Recommended Response Action Enter the command without the index.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0281 Message The specified object is READ ONLY and cannot be modified. Detailed Description The value being modified is READ only. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0283 Message The specified object value is not valid. Detailed Description The value given for the object is not valid. Recommended Response Action Enter a valid value for the corresponding object.
SWC0285 Message Object value is invalid. Detailed Description The value given for the object is not valid. Recommended Response Action Enter a valid value for the corresponding object. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The value of a parameter in the config file is invalid. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SWC0289 Invalid value in config file. Group:arg1, Object:arg2, Value: \"arg3\", Line [arg4] Message Arguments • • • • arg1 = Group Name arg2 = Object Name arg3 = Value arg4 = Line No. Detailed Description The specified objec value is invalid. Recommended Response Action Configure the specified object and assign a valid value. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0291 Message Another object exists with the specified value. Duplicate values are\nnot allowed for the requested object. Detailed Description Another object of the same value exists. Typically in the case of username. Recommended Response Action Change the specified value and re-try.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0293 Message The specified object is not recognized by iDRAC. Detailed Description The specified object is not present in the iDRAC. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0295 Message Invalid object name specified. Detailed Description The object name specified is incorrect. Recommended Response Action Refer to the list of objects in the group and choose the correct one.
SWC0297 Message Unable to remove passwords because file could not be saved. Detailed Description After the Groups are downloaded to a file, the passwords are to be deleted. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SWC0299 Message The Destination Email Address is invalid. Detailed Description The Email Address provided is invalid. Recommended Response Action Specify a valid Email address. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The IP address provided is not valid. Recommended Response Action Specify a valid IP Address. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0304 Message The -g option requires -u to also be specifed. Detailed Description The syntax of the fwupdate command is invalid.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0306 Message The -a option requires -g and -u to also be specifed. Detailed Description The syntax of the fwupdate command is invalid. Recommended Response Action Refer the help text for fwupdate subcommand.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0308 Message The -d option requires -g to also be specifed. Detailed Description The syntax of the fwupdate command is invalid. Recommended Response Action Refer the help text for fwupdate subcommand.
SWC0310 Message Invalid syntax. The -f is not valid with the option specified. Detailed Description The syntax of the getconfig command is invalid. Recommended Response Action Refer the help text for getconfig subcommand. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The syntax of the getconfig command is invalid. Recommended Response Action Refer the help text for getconfig subcommand. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0315 Message Failed to get object value. Detailed Description The getconfig subcommand failed to get the object value.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0317 Message The number of records to display must be greater than zero. Detailed Description The value for -c must be greater than zero. Recommended Response Action Enter a value greater than zero, for the option -c.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0319 Message The -i option is not valid with any other options. Detailed Description The syntax for the getraclog command is invalid. Recommended Response Action Refer the help text for getraclog command.
SWC0321 Message Unable to open the log for reading. Detailed Description Could not open the log file for reading. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The number of records specified to be displayed should be lesser than number of records available. Recommended Response Action Get the number of records available, and then run the command. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0102 Message The -m option is not supported by the interface being used.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0104 Message The -R option is not valid for the specified log. Detailed Description The specified log does not take in the -r option. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0106 Message The -u option is not supported on the current RAC configuration. Detailed Description The specified option is not supported on the RAC. Recommended Response Action No response action is required.
SWC0108 Message The service tag is not currently populated. Detailed Description The Service Tag string is empty. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The build information is not available for racdump. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0113 Message The -6 option can only be used in combination with the -d or -s option. Detailed Description The syntax of the setniccfg command is invalid.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0115 Message The -s option cannot be used with any other options. Detailed Description The syntax of the setniccfg command is invalid. Recommended Response Action Refer the help text for setniccfg subcommand.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0117 Message Invalid syntax. Both -f and -t must be specified. Detailed Description Invalid parameters passed to the function. Recommended Response Action Refer the help text for sslcertdownload subcommand.
SWC0119 Message Invalid certificate type specified with -t option. Detailed Description The syntax of the sslcertview command is invalid. Recommended Response Action Refer the help text for sslcertview subcommand. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The syntax of the sslcertview command is invalid. Recommended Response Action Refer the help text for sslcertview subcommand. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0124 Message The -u option requires -f to be specified. Detailed Description The syntax of the sslcsrgen command is invalid.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0126 Message Unable to download CSR file. Detailed Description Racadm tool was unable to download the generated CSR file. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0128 Message The Common Name (CN) field of the CSR Security group must\nbe configured before a CSR can be generated. Detailed Description The Common Name field is necessary for generating a CSR. It is not generated if Common Name is empty. Recommended Response Action Configure the Common Name field by using config command.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0130 Message Trap at specified index is not currently enabled. Detailed Description The Trap needs to be set for the particular index for the testtrap to go through. Recommended Response Action Set cfgIpmiPetAlertEnable in cfgIpmiPet group using config subcommand for the corresponding index.
SWC0132 Message Unable to send test trap. Please make sure that your trap\nhas been configured correctly and connectivity to \nthe destination endpoint exists. Detailed Description Either the destination Ip address is not reachable or the required values are not configured. Recommended Response Action Check for the connectivity to the configured Ip address.
SWC0134 Message The RAC log was cleared successfully Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0139 Total Records:arg1 Message Arguments • arg1 = Number of Records Detailed Description Success message.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0141 Message Certificate successfully downloaded from the RAC Detailed Description Success message.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0143 Message SSL key successfully uploaded to the RAC. Detailed Description Success message. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0145 Message A CSR was generated successfully Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0147 Message ASR request completed successfully Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SWC0149 Message Test trap sent successfully. Detailed Description The requested SNMP test trap alert was successfully sent. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0154 Message Generating CSR. Please wait... Detailed Description Success message. Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0156 Message CSR file downloaded from RAC successfully Detailed Description Success message. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0158 Message User CA certificate successfully uploaded to the RAC. Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
SWC0160 Message PK SSH Authentication Key file successfully uploaded to the RAC. Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0204 Message Key text successfully uploaded Detailed Description Help Text. Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0206 Message View user certificate information Detailed Description Help Text. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0208 Message Disconnect Virtual Media connections Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SWC0210 Message Display NIC teaming information Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Help Text. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0215 Message Disable Remote File Started.Please check status using -s option to know Remote File Share is ENABLED or DISABLED.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0217 Message The -c option requires -u to also be specifed. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0219 Message The -p option requires -c to also be specifed. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0221 Message The -l option requires -c to also be specifed. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command.
SWC0223 Message Invalid syntax. The -d option is not valid with -p. Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The syntax of the command is incorrect. Recommended Response Action Refer to the help for remote image command. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0228 Message Partition label must be an alphanumeric character string. Detailed Description Invalid values passed to the function.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0230 Message vFlash not enabled. Detailed Description vFlash is not enabled. This may be because the user does not have enough privileges. Recommended Response Action Enable vFlash and re-try.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0232 Message Remote RACADM commands are not supported on this iDRAC. To upgrade your iDRAC version, contact your service provider. Detailed Description Remote RACADM commands are not supported on the current iDRAC. Recommended Response Action If remote RACADM is a necessity, upgrade the iDRAC version.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0234 Message Remote host is not reachable or connection is interrupted. Detailed Description The remote host specified for the ftp update is not reachable. Recommended Response Action Check the connectivity between iDRAC and the remote host used for the ftp update.
SWC0236 Message Key successfully deleted. Detailed Description The specified public key was deleted from iDRAC. Recommended Response Action No response action is required. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The key specified by the public key is too long. Recommended Response Action Request for a valid public key from the system and re-try the command. Category Configuration SubCategory SWC = Software Config Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Recommended Response Action Disable DNS Server DHCP and re-try the command. Category Configuration SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0241 Message Power Cap Enable not set.
SubCategory SWC = Software Config Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0243 Message Certificate regenerated successfully and webserver restarted Detailed Description SSL Certificate is regenerated successfully and the Web server is restarted.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0245 Message Failed to set object value because local configuration using RACADM is disabled. Detailed Description Local configuration using RACADM is disabled. This limits local configuration privileges such as resetting object values.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SWC0325 Message The specified object is WRITE-ONLY and cannot be displayed. Detailed Description The requested property is write-only. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC1905 Message RAC Virtual Console configuration has been changed. Detailed Description RAC Virtual Console configuration has been changed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC1910 User IDarg1User Name has been changed. Message Arguments • arg1 = username Detailed Description User ID Name has been changed. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC1912 User IDarg1User Access Right has been changed. Message Arguments • arg1 = username Detailed Description User ID Access Right has been changed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SWC1914 Message Network Time Protocol configuration is disabled. Detailed Description Network Time Protocol configuration is disabled. Recommended Response Action No response action is required.
SWC1916 Message Network Time Protocol server configuration has changed. Detailed Description Network Time Protocol server configuration has changed. Recommended Response Action No response action is required. Category Audit SubCategory SWC = Software Config Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
53 SYS Event Messages SYS101 Message Server Administor Data Manager service has started. Detailed Description The Server Administratort Data Manager service has started. Recommended Response Action No response action is required. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS103 Message Administrator has started. Detailed Description The Server Administrator has started. Recommended Response Action No response action is required. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS105 Unable to process the event:arg1Date and time of event:arg2. Message Arguments • • arg1 = event arg2 = date time Detailed Description The current software version is unable to process this event because of an internal error. Recommended Response Action Contact your service provider.
Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS107 Message A system reboot was initiated by the user. Detailed Description The user initiated a system reboot. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS109 Message A system power cycle was initiated by the user. Detailed Description The user has initiated a system power cycle action. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS111 Message The actions Shutdown OS First and Power Off System were initiated by the user. Detailed Description The actions will shut down the operating system and then the system. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS113 Message An invalid action was requested by the user. Detailed Description An invalid action was requested by the user. Recommended Response Action No response action is required. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS115 Message The power cord sensor is non-functional. Detailed Description The power cord sensor becomes non-functional because of one of the following reasons: 1) The power cable may not be connected properly or disconnected.
SubCategory SYS = System Info Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS117 Message The input power supply is restored. Detailed Description The input power supply is restored to the system. Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS001 Message The operation was successful. Detailed Description The operation requested successfully completed. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS003 Missing parameters:arg1. Message Arguments • arg1 = parameter names Detailed Description One or more required parameters needed for the operation are missing. Recommended Response Action Refer to the Lifecycle Controller Remote Services documentation and retry the operation with the required parameters.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS005 Message AttributeName array and AttributeValue array element count mismatch. Detailed Description The AttributeName input array and AttributeValue input array do not have the same number of elements.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS007 Input out of range forarg1. Message Arguments • arg1 = attribute name Detailed Description The input value for the attribute being set is not within the acceptable range for the attribute.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE FALSE TRUE SYS1001 Message System is turning off. Detailed Description System is turning off. Recommended Response Action No response action is required. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
SYS1003 Message System CPU Resetting. Detailed Description System is performing a CPU reset because of system power off, power on or a warm reset like CTRL-ALT-DEL. Recommended Response Action No response action is required. Category Audit SubCategory SYS = System Info Severity Severity 3 (Informational) Trap/EventID 8579 LCD Message No LCD message display defined. Initial Default.
SYS044 Message Unable to export one or more component configurations. Detailed Description Unable to collect the configuration information for one or more components. An internal error occurred while processing component information. Recommended Response Action Enable Collect System Inventory On Restart (CSIOR) using Lifecycle Controller and restart the system. Make sure that inventory collection is complete before retrying the operation. For more information, see the Lifecycle Controller Users Guide.
SYS046 Message Unable to import the system configuration XML file from the network share. Detailed Description An error occurred while copying the system configuration XML file from the network share. Recommended Response Action If the file is being copied from an NFS share, make sure that it is accessible from iDRAC. If the file is being copied from a CIFS share, make sure that it is accessible from iDRAC using the share credentials provided.
SYS048 System configuration XML input file contains invalid characters,arg1at linearg2. Message Arguments • • arg1 = character arg2 = line Detailed Description The operation expected a valid XML that is compliant with the system configuration schema. However, the system configuration file does not contain valid XML content. Recommended Response Action View the file in any Web browser to check for invalid characters.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS051 Message The system could not be shut down within the specified time. Detailed Description Sometimes, the operating system on the server may not allow a graceful shutdown or may not complete within the specified graceful shutdown timeout. This error indicates that the system could not be shutdown within the time specified.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS053 Message Successfully imported and applied system configuration XML file. Detailed Description Configuration changes specified in the system configuration XML file were successfully applied. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS055 Message Import of system configuration XML file operation completed with errors. Detailed Description The configuration specified in the systen configuration XML file was applied, but there were some errors. The Lifecycle Controller Log contains the details of the component configurations that failed.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS057 Message Exporting system configuration XML file. Detailed Description The current system configuration is being collected and the system configuration XML file is being generated. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS059 Message Component configuration successfully changed. Detailed Description Configuration changes for the component identified by the Fully Qualified Device Descriptor (FQDD) were successfully applied. Recommended Response Action No response action is required. See Lifecycle Log for details.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS061 Message Unable to complete component configuration. Detailed Description Some configuration changes for the component identified by the Fully Qualified Device Descriptor (FQDD) in the configuration job results were not successfully applied.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS063 Message Input file for import configuration operation is invalid. The expected root element was not closed. Detailed Description The input file for the import configuration operation does not contain a closed root element.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS065 Message Input file for import configuration operation cannot be found or opened. Detailed Description An internal error occurred opening the input configuration XML file. An iDRAC reset is required. Recommended Response Action Reset iDRAC and retry the operation.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS067 Message Unable to complete application of configuration XML file values. Detailed Description Some or all configuration actions during the import of configuration XML operation did not compltete successfully. The configuration action details are logged into the Lifecycle Log.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS069 Message No changes were applied since the current component configuration matched the requested configuration. Detailed Description The settings specified in the system configuration XML file match the current configuration for all components. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE SYS071 Message System configuration XML export operation timed-out. Detailed Description The export of system configuration XML did not complete because the operation took too long. Recommended Response Action Make sure the Collect System Inventory On Restart (CSIOR) Lifecycle Controller setting is enabled and reboot the system.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS073 Message Unable to apply changes that require system reboot because the Lifecycle Controller State setting is disabled in the configuration XML. Detailed Description The import of system configuration XML file operation completed with errors because the Lifecycle Controller State was disabled in the input XML.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE SYS075 Message Unable to perform the import operation because the specified file does not exist on the remote share. Detailed Description Unable to perform the import operation because the specified file does not exist on the remote share.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE 1304 FALSE FALSE
54 TMP Event Messages TMP1000 arg1exceeded the maximum warning threshold. Message Arguments • arg1 = tempsensor name Detailed Description The enclosure is too hot. A variety of factors can cause the excessive temperature. For example, a fan may have failed, the thermostat may be set too high, or the room temperature may be too hot. Recommended Response Action Check for factors that may cause overheating. For example, verify that the enclosure fan is working.
Category Storage SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 4210 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE TMP1002 arg1has exceeded the maximum failure threshold. Message Arguments • arg1 = tempsensor name Detailed Description The enclosure is too hot.
Detailed Description The enclosure is too cold. Recommended Response Action Check whether the thermostat setting is too low and whether the room temperature is too cool. Category Storage SubCategory TMP = Temperature Severity Severity 1 (Critical) Trap/EventID 4209 LCD Message No LCD message display defined. Initial Default.
Detailed Description You have changed the value for the minimum temperature probe warning threshold. This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory TMP = Temperature Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
Detailed Description Ambient air temperature is too warm or one or more fans may have failed. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health SubCategory TMP = Temperature Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message System board temperature is outside of range Check Fans Initial Default.
Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
Detailed Description Ambient air temperature is too warm or one or more fans may have failed. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health SubCategory TMP = Temperature Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message Memory module temperature is outside of range. Check Fans Initial Default.
Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
Detailed Description Ambient air temperature is too warm or one or more fans may have failed. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health SubCategory TMP = Temperature Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message The temperature is outside of range. Check Fans Initial Default.
Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0121 Message The system inlet temperature is greater than the upper critical threshold. Detailed Description Ambient air temperature is too warm.
Trap/EventID 2161 LCD Message Inlet temperature is outside of range . Check environment Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0123 Message The system inlet temperature is within range. Detailed Description None Recommended Response Action Check system operating environment.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0125 Message Disk drive bay temperature is less than the lower critical threshold. Detailed Description Ambient air temperature is too cool. Recommended Response Action Check system operating environment.
TMP0127 Message Disk drive bay temperature is greater than the upper critical threshold. Detailed Description Ambient air temperature is too warm or one or more fans may have failed. Recommended Response Action Check system operating environment and review event log for fan failures. Category System Health SubCategory TMP = Temperature Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory TMP = Temperature Severity Severity 3 (Informational) Trap/EventID 2163 LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory TMP = Temperature Severity Severity 1 (Critical) Trap/EventID 2161 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0132 Message The control panel temperature is greater than the upper warning threshold.
Trap/EventID 2161 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0134 Message The control panel temperature is outside of range. Detailed Description Ambient air temperature is too warm or cool. Recommended Response Action Check system operating environment and review event log for fan failures.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE TMP0136 Message Insufficient system cooling detected, system is shutdown. Detailed Description More then the minimun number of fans have been removed or failed in the system. System will not start or will shutdown. Recommended Response Action Replace failed fans. Install minimun requires fans.
TMP0200 CPUarg1temperature is less than the lower warning threshold. Message Arguments • arg1 = number Detailed Description System performance may be degraded. Recommended Response Action Check system operating environment. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID 2162 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0202 CPUarg1temperature is greater than the upper warning threshold. Message Arguments • arg1 = number Detailed Description System performance may be degraded. Recommended Response Action Check system operating environment, fans, and heatsinks.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE TMP0204 CPUarg1temperature is outside of range. Message Arguments • arg1 = number Detailed Description System performance may be degraded. Recommended Response Action Check system operating environment, fans, and heatsinks.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE TMP500 Thearg1sensor has failed with value thearg2degrees Celsius. Message Arguments • • arg1 = sensor name arg2 = temperature Detailed Description A temperature sensor identified in the message has failed.
Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE TMP502 Thearg1sensor has returned to a normal state with a value ofarg2degrees Celsius.
Recommended Response Action Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider. Otherwise, change the warning threshold for the temperature sensor (if applicable) such that it corresponds to the hardware configuration. Category System Health SubCategory TMP = Temperature Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined.
TMP505 Thearg1sensor has failed with a value ofarg2degrees Celsius. Message Arguments • • arg1 = sensor name arg2 = temperature Detailed Description The temperature sensor identified in the message has failed. Recommended Response Action Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
55 TMPS Event Messages TMPS0100 Message Inlet temperature is above warning level for extended duration. Detailed Description Inlet temperature has been above the warning threshold for duration of 8% or more for the operational time during the last one year. Recommended Response Action This condition will occur if the ambient temperature is high. Make sure the ambient temperature of the environment is in normal range.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE TMPS0102 Message Inlet temperature is above warning level for extended duration. Detailed Description Inlet temperature has been above the warning threshold for duration of 10% or more for the operational time during the last one year. Recommended Response Action This condition will occur if the ambient temperature is high.
56 UEFI Event Messages UEFI0000 Message CPU Exception Type 0x00: Divide by Zero (Software). Detailed Description A CPU type 0x00, divide by zero exception, (type 0x00) occurred in the pre-boot UEFI environment. The software attempted to do a mathematical divide by zero, an illegal operation. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE UEFI0002 Message CPU Exception Type 0x04: Overflow (Software). Detailed Description A CPU overflow exception (type 0x04) occurred in the pre-boot UEFI environment. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software.
UEFI0004 Message CPU Exception Type 0x06: Invalid Opcode (Software). Detailed Description A CPU invalid opcode exception (type 0x06) occurred in the pre-boot UEFI environment. The software attempted to execute invalid code. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software.
Detailed Description A CPU double fault exception (type 0x08) occurred. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software. Category System Health SubCategory UEFI = UEFI Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory UEFI = UEFI Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE UEFI0009 Message CPU Exception Type 0x0B: Segment Not Present (Software).
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE UEFI0011 Message CPU Exception Type 0x0D: General Protection (Software). Detailed Description A CPU general protection (type 0x0D) exception occurred in the pre-boot UEFI environment.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE UEFI0013 Message CPU Exception Type 0x10: Floating Point Error (Software). Detailed Description A CPU floating point error (type 0x10) exception occurred in the pre-boot UEFI environment. Recommended Response Action Recently installed hardware or updated software may cause this exception. Update or remove the hardware or software.
UEFI0015 Message Lifecycle Controller (LC) firmware was not accessible and is therefore in Recovery mode. Detailed Description The BIOS is unable to access the Lifecycle Controller firmware. No Lifecycle Controller functionality is available while in Recovery Mode. Recommended Response Action Perform the following actions: 1)Reboot the system. 2) Press F2 during boot to enter System Setup. 3) Select iDRAC Settings then Lifecycle Controller. 4) Change Lifecycle Controller back to Enabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE UEFI0017 Message Lifecycle Controller (LC) firmware was not accessible and is therefore in Recovery mode. Detailed Description Unable to locate a file required to run Lifecycle Controller. No Lifecycle Controller functionality is available while in Recovery Mode.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE UEFI0019 Message Lifecycle Controller (LC) is unable to complete a requested task or function and prevented the boot process from completing on multiple attempts. LC is in Recovery Mode.
57 USR Event Messages USR0001 arg1 Message Arguments • arg1 = message Detailed Description No detailed description is required. Recommended Response Action No response action is required. Category Work Notes SubCategory USR = User Tracking Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE USR0014 Message The current user session is invalid. Detailed Description The user session which is currently in use is invalid. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE USR0015 Message The specified user does not exist. Detailed Description The specified user does not exist. Recommended Response Action Verify the existing users and enter a valid username. Category Audit SubCategory USR = User Tracking Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined.
USR0017 Message No active sessions currently exist for the specified user. Detailed Description There are no active sessions on the iDRAC for the specified user. Recommended Response Action No response action is required. Category Audit SubCategory USR = User Tracking Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The specified username exceeds the prescribed limit (255) Recommended Response Action No response action is required. Category Audit SubCategory USR = User Tracking Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Audit SubCategory USR = User Tracking Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE USR0023 Message The current user privilege is not valid. Detailed Description The user privilege is invalid.
Category Audit SubCategory USR = User Tracking Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description UserID closing session from IP Address. Recommended Response Action No response action is required. Category Audit SubCategory USR = User Tracking Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
58 VDR Event Messages VDR1 arg1failed. Message Arguments • arg1 = VD Name Detailed Description A storage component such as a physical disk or an enclosure has failed. The failed component may have been identified by the controller while performing a task such as a rescan or a check consistency. Recommended Response Action Replace the failed component. You can identify which component has failed by locating the component that has a red "X" for its status.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR11 arg1has started initializing. Message Arguments • arg1 = virtual disk Detailed Description This message is generated after initialization of a virtual disk starts.
SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR13 arg1rebuild has started. Message Arguments • arg1 = VD Name Detailed Description This alert is provided for informational purposes.
Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID 4355 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VDR15 Initialization ofarg1was cancelled. Message Arguments • arg1 = virtual disk Detailed Description The initialization operation could not be completed.
Recommended Response Action Check that all the physical disks of the virtual disk are in a healthy condition. Replace any disks that are not healthy and restart the operation. If this is not the problem, delete the virtual disk and restore the data to the disk from a backup copy. Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) Trap/EventID 4353 LCD Message No LCD message display defined. Initial Default.
Detailed Description A physical disk included in the virtual disk has failed or was removed. Recommended Response Action If a physical disk has failed, replace the physical disk. Restart the virtual disk initialization. Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) Trap/EventID 4353 LCD Message No LCD message display defined. Initial Default.
Detailed Description The virtual disk has returned to a healthy state and is working properly. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID 4355 LCD Message No LCD message display defined. Initial Default.
Detailed Description This message is generated after a consistency check completes on a virtual disk. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID 4355 LCD Message No LCD message display defined. Initial Default.
Detailed Description This message is generated after initialization completes on a virtual disk. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The check consistency on a virtual disk has resumed processing after a pause. Recommended Response Action This alert is provided for informational purposes. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
the mirror returns to being a physical disk and becomes available for inclusion in another virtual disk. Recommended Response Action This alert is provided for informational purposes. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description A user changed the write policy for a virtual disk. Recommended Response Action This alert is provided for informational purposes. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Arguments • arg1 = virtual disk Detailed Description Background initialization of a virtual disk has started. This is an automated process that writes the parity or mirror data on newly created virtual disks. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID 4355 LCD Message No LCD message display defined. Initial Default.
VDR34 Background initialization failed forarg1. Message Arguments • arg1 = virtual disk Detailed Description Background initialization of a virtual disk failed. Recommended Response Action Run a consistency check on the virtual disk. If that fails, check the health of the member drives of the virtual disk and then recreate. Category Storage SubCategory VDR = Virtual Disk Severity Severity 1 (Critical) Trap/EventID 4353 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR36 arg1initialization is in-progressarg2. Message Arguments • • arg1 = VD Name arg2 = progresspercent Detailed Description Virtual disk initialization is in-progress. This alert is provided for informational purposes. Recommended Response Action No response action is required.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR38 arg1is renamed. Message Arguments • arg1 = VD Name Detailed Description A user renamed a virtual disk. This alert is provided for informational purposes. Recommended Response Action No response action is required.
Trap/EventID 4355 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE FALSE TRUE FALSE FALSE FALSE TRUE FALSE VDR4 arg1was created. Message Arguments • arg1 = virtual disk Detailed Description This message is generated after a virtual disk was created on a controller. Recommended Response Action No response action is required.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR41 arg1read policy has changed. Message Arguments • arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required.
SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR43 Dedicated hotspare unassigned physical diskarg1. Message Arguments • arg1 = args Detailed Description This alert is provided for informational purposes.
Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR45 arg1blink has been initiated. Message Arguments • arg1 = VD Name Detailed Description This alert is provided for informational purposes.
Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR47 A disk media error was corrected onarg1.
Detailed Description This alert is provided for informational purposes. The virtual disk has inconsistent data. This may be caused when a power loss or system shutdown occurs while data is being written to the virtual disk. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID 4355 LCD Message No LCD message display defined. Initial Default.
VDR5 arg1was deleted. Message Arguments • arg1 = virtual disk Detailed Description The controller removed a virtual disk. This is due to a delete virtual disk operation, a reset configuration operation, or the removal of every physical disk that was a member of the virtual disk. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VDR51 The consistency check process made corrections and completed onarg1. Message Arguments • arg1 = virtual disk Detailed Description The consistency check completed on the virtual disk after making corrections. Recommended Response Action No response action is required.
Severity Severity 2 (Warning) Trap/EventID 4354 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VDR53 The consistency check logging of inconsistent parity data is disabled forarg1. Message Arguments • arg1 = virtual disk Detailed Description The consistency check can no longer report errors in the parity data.
SubCategory VDR = Virtual Disk Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR55 arg1initialization has failed. Message Arguments • arg1 = VD Name Detailed Description The controller cannot communicate with attached devices.
Recommended Response Action Replace the missing or failed physical disk. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR57 Background Initialization inarg1corrected medium error.
Detailed Description Virtual disk bad blocks are due to presence of unrecoverable bad blocks on one or more member physical disks. Recommended Response Action Recovering a physical disk bad block depends on the RAID level and state of the virtual disk. If a virtual disk is redundant, the controller can recover a bad block on a physical disk. If a virtual disk is not redundant, then the physical disk bad block results in a virtual disk bad block.
Arguments • arg1 = VD Name Detailed Description This alert is provided for informational purposes. Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
VDR8 arg1has become degraded. Message Arguments • arg1 = virtual disk Detailed Description This message occurs when a physical disk in the disk group was removed or when a physical disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity information) and only one physical disk has failed, the virtual disk can be rebuilt. Recommended Response Action Configure a hot spare for the virtual disk if it is not already configured.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VDR91 Consistency check forarg1has detected multiple uncorrectable medium errors. Message Arguments • arg1 = virtual disk Detailed Description This message occurs if there are medium errors in the physical drives. Recommended Response Action Replace the failed drives.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VDR93 arg1bad block medium error is cleared. Message Arguments • arg1 = VD Name Detailed Description This alert message occurs if there are medium errors in the physical drives. Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VDR95 Unable to log blockarg1.Bad block table onarg2is full. Message Arguments • • arg1 = arg arg2 = VD Name Detailed Description This alert message occurs if the virtual disk has bad blocks.
Severity Severity 3 (Informational) Trap/EventID 4355 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE FALSE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VDR97 Patrol Read corrected a media error onarg1. Message Arguments • arg1 = VD Name Detailed Description The Patrol Read task has encountered an error such as a bad disk block and remapped data to correct the error.
SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR101 Hot Spare Protection policy deviation with severity set at Informational level occured forarg1.
Recommended Response Action Make appropriate assignments of hotspares to meet the policy. Category Storage SubCategory VDR = Virtual Disk Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The secure virtual disk operation was successful on the security capable virtual disk identified in the message. A security capable virtual disk is created using only Self-Encrypting Drives (SED). Recommended Response Action No response action is required. Category Storage SubCategory VDR = Virtual Disk Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
VDR106 arg1on spun down power save mode drives is not available. Message Arguments • arg1 = virtual disk name Detailed Description This alert is generated after successfully configuring a virtual disk on at least one spundown drive. The virtual disk creation is not yet complete on the remaining spundown drives because the drives are still spinning up. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR108 Successfully created Controller Enhanced cache (arg1). Message Arguments • arg1 = virtual disk name Detailed Description The Controller Enhanced cache identified in the message was successfully created. Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR110 Unrecoverable storage medium error detected onarg1. Message Arguments • arg1 = virtual disk name Detailed Description This alert is generated when an unrecoverable storage medium error is detected on the virtual disk.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VDR112 Deleted thearg1. Message Arguments • arg1 = virtual disk Detailed Description The controller removed a virtual disk because of a delete virtual disk operation or a reset configuration operation.
59 VF Event Messages VF001 Message Command successful. Detailed Description The command was successful Recommended Response Action No response action is required. Category Configuration SubCategory VF = vFlash Media Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF003 Missing required parameter:arg1 Message Arguments • arg1 = parameter name Detailed Description The required input parameter is missing. Recommended Response Action Refer the iDRAC User Guide for the required input parameters for this method.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF005 Message Empty partition creation successful Detailed Description A partition with no image was created. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF007 Message Image partition creation successful Detailed Description A partition with an image was created. Recommended Response Action No response action is required. Category Configuration SubCategory VF = vFlash Media Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
VF009 Message Partition formatting successful Detailed Description The specified partition was formatted. Recommended Response Action No response action is required. Category Configuration SubCategory VF = vFlash Media Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The specified password was not correct. Recommended Response Action Verify the password supplied. Category Configuration SubCategory VF = vFlash Media Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory VF = vFlash Media Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF014 Message VFlash not disabled Detailed Description Enabling vFlash failed because the vFlash feature is not disabled.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF016 Message SD card is read only Detailed Description The SD card is not writable. Recommended Response Action Check the write-protection tab of the SD card.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF018 Message Invalid partition index Detailed Description The specified partition index is not valid for the command. Recommended Response Action Check that the partition exists. Category Configuration SubCategory VF = vFlash Media Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined.
VF020 Message Exceeded maximum number of partitions Detailed Description The number of partitions exceeded the maximum number allowed on a SD card. Recommended Response Action This SD card has reached the partition limit. Delete any partitions that are not necessary and try again. Category Configuration SubCategory VF = vFlash Media Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The size specified is lower than the minimum allowed for a partition. Recommended Response Action Try a larger partition size. Category Configuration SubCategory VF = vFlash Media Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory VF = vFlash Media Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF027 Message Partition already attached Detailed Description This partition is attached and attempts to attach it will fail. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF029 Message Insufficient permission Detailed Description The user account credentials provided for this vFlash operation do not have the correct privileges. Virtual Media Access privilege is required to perform vFlash SD Card media operations. Recommended Response Action Use a different user account the has Virtual Media Access privilege.
VF031 Message Invalid partition label Detailed Description The specified partition label is not a valid label. Recommended Response Action Try a label that complies with the standards for an OS volume label. Category Configuration SubCategory VF = vFlash Media Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The specified format type is not a valid type. Recommended Response Action Try a format type that is supported. Category Configuration SubCategory VF = vFlash Media Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory VF = vFlash Media Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF036 Message Attach partition successful Detailed Description The partition was attached. Recommended Response Action No response action is required.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF038 Message Detach partition successful Detailed Description The partition was detached. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF040 Message Image hash verification failed Detailed Description The downloaded image has failed the hash verification. Recommended Response Action Try the download again.
VF042 Message Remote file missing Detailed Description The remote file could not be found. Recommended Response Action Check the mount area. Category Configuration SubCategory VF = vFlash Media Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description File transfer failed. This could be due to network problems,an operational problem with the file server. Recommended Response Action Try the download again. If this problem persists, validate that the network share is operational. Category Configuration SubCategory VF = vFlash Media Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category Configuration SubCategory VF = vFlash Media Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF047 Message Unsupported SD Card Detailed Description This is not a Dell-licensed VFlash. Recommended Response Action This feature requires a Dell SD card.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF049 Message Initialize media failed Detailed Description Initializing SD card failed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VF051 Message Export partition failed Detailed Description Copying partition failed. Recommended Response Action No response action is required. Category Configuration SubCategory VF = vFlash Media Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
VF0060 Message Unable to perform the requested operation. Make sure the SD card is inserted and enabled. Detailed Description The SD card was not detected. Therefore, the requested operation cannot be completed. Recommended Response Action Verify whether the SD card is inserted and enabled, then re-try. Category System Health SubCategory VF = vFlash Media Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
60 VFL Event Messages VFL1001 Removable Flash Mediaarg1is present. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID 2507 LCD Message No LCD message display defined. Initial Default.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VFL1003 Removable Flash Mediaarg1is not IPMI-function ready. Message Arguments • arg1 = name Detailed Description The removable flash media is installed but improperly configured or failed to initialize.
Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VFL1005 Removable Flash Mediaarg1is not ready. Message Arguments • arg1 = name Detailed Description The media is being prepared or is under maintenance. If the problem persists, reinstall the card.
SubCategory VFL = vFlash Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VFL1007 Removable Flash Mediaarg1is online. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required.
Category System Health SubCategory VFL = vFlash Event Severity Severity 1 (Critical) Trap/EventID 2505 LCD Message Removable Flash Media failed. Check SD Card Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VFL1009 Removable Flash Mediaarg1is operating normally.
Recommended Response Action No response action is required. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID 2507 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE FALSE TRUE VFL1011 Removable Flash Mediaarg1was deactivated.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VFL1013 Removable Flash Mediaarg1has finished booting.
Detailed Description The card is write-protected by the physical latch on the SD card. IDSDM cannot use a writeprotected card. Recommended Response Action if unintended, remove the media and disable write protection. Category System Health SubCategory VFL = vFlash Event Severity Severity 2 (Warning) Trap/EventID 2506 LCD Message Removable Flash Media is write protected. Check SD Card Initial Default.
Detailed Description The SD card is not detected or not installed. Recommended Response Action If unintended, reinstall the flash media. Category System Health SubCategory VFL = vFlash Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category Configuration SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0704 Message SD card is not present and could not be initialized.
Category Configuration SubCategory VFL = vFlash Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0708 Message SD card is busy with another operation and could not be initialized.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0711 Message SD card is write-protected and could not be initialized. Detailed Description An error occurred while initializing the SD card because the SD card write-protection feature is enabled.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0713 Message One or more partitions are currently attached; the SD card could not be initialized. Detailed Description none Recommended Response Action Detach the partitions and try again.
VFL0715 Message Error occurred while initializing the SD Card due to insufficient permission. Detailed Description None Recommended Response Action Contact the administrator for the required permissions and try again. Category Configuration SubCategory VFL = vFlash Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The SD card is in use by another process. Initialization requires exclusive access to the SD card to complete the initialization. Recommended Response Action The SD card is in use by another process. Retry after a few minutes. Category Configuration SubCategory VFL = vFlash Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0002 Message If the local server video is turned ON it will take 15 seconds to turn OFF Detailed Description Success message.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0004 Partitionarg1does not exist. Message Arguments • arg1 = Partition Number/Index Detailed Description The specified partition number does not exist and hence cannot be queried. Recommended Response Action No response action is required.
LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0006 Message Failed to perform vFlash Partition operation. Detailed Description The requested operation was not executed. Recommended Response Action No response action is required.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0008 Message Invalid partition image type. Detailed Description Invalid values passed to the function. Recommended Response Action Refer the help text for vflashpartition command. Category System Health SubCategory VFL = vFlash Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined.
VFL0010 Message Invalid partition index value. Detailed Description Invalid values passed to the function. Recommended Response Action Refer the help text for vflashpartition command. Category System Health SubCategory VFL = vFlash Event Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description A list of partitions was requested, but there were no partitions present. Recommended Response Action No response action is required. Category System Health SubCategory VFL = vFlash Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory VFL = vFlash Event Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0015 Message Failted to set the object value. Detailed Description Failed to set the value of the First Boot Device.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0017 Message A vFlash SD card partition operation is in progress. Resetting the iDRAC may corrupt the vFlash SD card. Use -f flag to force racreset. Detailed Description You cannot reset iDRAC, if a vFlash SD card operation is in-progress.
Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0019 Message An operation is in-progress on the SD card. Detailed Description An operation is in-progress on the SD card. Recommended Response Action Wait for the operation to complete.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0021 Message vFlash is not enabled. Detailed Description vFlash operations are not enabled.
VFL0023 Message SD card is not initialized. Detailed Description SD card is not initialized. Either the card is not properly formatted or it may not be recognised by your service provider. Recommended Response Action Format the SD card. Make sure the card is recognized by your service provider. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The space available on the SD card is not sufficient. Recommended Response Action If there is data on the SD card, format the card. Use a different SD card that has free space. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0028 Message Partition size below minimum. Detailed Description The size allocated to the parition is less than the minimum limit.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0030 Message Partition is in use. Detailed Description The partition is in use. Recommended Response Action Wait for the operation on the partition to complete.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0032 Message Partition index is not unique. The requested partition is in use. Detailed Description A partition with the same index exists on the SD card. Recommended Response Action Either delete the duplicate partition or choose a different index for the new partition.
VFL0034 Message Partition descritption is too long. Detailed Description The description for the partition exceeds the maximum permissible limit. Recommended Response Action Description should be brief. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description The data on the partition may be inconsistent. Recommended Response Action Format the SD card and create the partition again. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0039 Message Invalid partition format type. Detailed Description The specified partition format type is not valid.
Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0041 Message Status pending. Requested operation is in-progress. Detailed Description The status you are querying is pending, the requested operation is in-progress. Recommended Response Action Wait for the requested operation to complete.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VFL0043 Message Media is not ready. Detailed Description The SD card is busy with an operation. Recommended Response Action Wait for the operation to complete. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
VFL0045 Message Invalid password. Detailed Description The specified remote share password is invalid. Recommended Response Action Provide the correct password for the remote share. Category System Health SubCategory VFL = vFlash Event Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
61 VFLA Event Messages VFLA1000 Removable Flash Mediaarg1is absent. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VFLA = vFlash Absent Severity Severity 3 (Informational) Trap/EventID 2515 LCD Message No LCD message display defined. Initial Default.
62 VLT Event Messages VLT0100 Processor modulearg1voltage is less than the lower warning threshold. Message Arguments • arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect processor socket for bent pins.
Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message Processor module voltage is outside of range. Contact support Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VLT0102 Processor modulearg1voltage is greater than the upper warning threshold.
Category System Health SubCategory VLT = Voltage Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message Processor module voltage is outside of range . Contact support Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VLT0104 Processor modulearg1voltage is outside of range.
Recommended Response Action No response action is required. Category System Health SubCategory VLT = Voltage Severity Severity 3 (Informational) Trap/EventID 2171 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VLT0200 The system boardarg1voltage is less than the lower warning threshold.
Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Arguments • arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
VLT0205 The system boardarg1voltage is within range. Message Arguments • arg1 = name Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VLT = Voltage Severity Severity 3 (Informational) Trap/EventID 2171 LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0207 The memory modulearg1arg2voltage is less than the lower critical threshold. Message Arguments • • arg1 = number arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Trap/EventID 2170 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0209 The memory modulearg1arg2voltage is greater than the upper critical threshold. Message Arguments • • arg1 = number arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Category System Health SubCategory VLT = Voltage Severity Severity 1 (Critical) Trap/EventID 2169 LCD Message Memory module voltage is outside of range. Contact support Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0211 The memory modulearg1arg2voltage is within range.
Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory VLT = Voltage Severity Severity 2 (Warning) Trap/EventID 2170 LCD Message No LCD message display defined. Initial Default.
Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Arguments • arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat hard disks in the bay. Reconnect all cables attached to the bay. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
VLT0218 Thearg1voltage is less than the lower warning threshold. Message Arguments • arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions 2) Reduce system to minimum configuration, inspect and re-install system cables. 3) If the problem persists, contact technical support.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0220 Thearg1voltage is greater than the upper warning threshold. Message Arguments • arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
LCD Message The voltage is outside of range. Contact support Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0222 Thearg1voltage is outside of range. Message Arguments • arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Severity Severity 3 (Informational) Trap/EventID 2171 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VLT0224 The memory modulearg1voltage is less than the lower warning threshold. Message Arguments • arg1 = name Detailed Description System hardware detected an over voltage or under voltage condition.
Category System Health SubCategory VLT = Voltage Severity Severity 1 (Critical) Trap/EventID 2169 LCD Message Memory module voltage is outside of range. Contact support Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0226 The memory modulearg1voltage is greater than the upper warning threshold.
Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method. Category System Health SubCategory VLT = Voltage Severity Severity 1 (Critical) Trap/EventID 2169 LCD Message Memory module voltage is outside of range. Contact support Initial Default.
Detailed Description None Recommended Response Action No response action is required. Category System Health SubCategory VLT = Voltage Severity Severity 3 (Informational) Trap/EventID 2171 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VLT0230 The mezzanine cardarg1arg2voltage is less than the lower warning threshold.
Arguments • • arg1 = number arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Recommended Response Action 1) Review system logs for power supply exceptions. 2) Reseat the mezzanine card. 3) If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0233 The mezzanine cardarg1arg2voltage is greater than the upper critical threshold. Message Arguments • • arg1 = number arg2 = name Detailed Description System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode.
Trap/EventID 2169 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0235 The mezzanine cardarg1arg2voltage is within range. Message Arguments • • arg1 = number arg2 = name Detailed Description None Recommended Response Action No response action is required.
Category System Health SubCategory VLT = Voltage Severity Severity 2 (Warning) Trap/EventID 2170 LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE TRUE VLT0301 CPUarg1arg2voltage is less than the lower critical threshold.
Detailed Description High voltages may be the result of problem with the voltage regulator or a problem with the processor. Elevated voltages may result in damage to the processor or other electronic components in side the system. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support.
VLT0304 CPUarg1arg2voltage is outside of range. Message Arguments • • arg1 = number arg2 = name Detailed Description Voltages outside the allowable range may damage electrical components or may cause the system to shutdown. Recommended Response Action 1) Turn system off and remove input power for one minute. Re-apply input power and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact technical support.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset TRUE TRUE TRUE TRUE FALSE FALSE FALSE TRUE FALSE VLT400 Thearg1sensor has failed with a valuearg2Volts. Message Arguments • • arg1 = sensor name arg2 = voltage Detailed Description A voltage sensor identified in the message may have failed. This condition can cause system performance issues and degradation in the moitoring capability of the system.
sensor, remove the processor module and inspect processor socket, and replace if required. If the issue persists, contact your service provider. Category System Health SubCategory VLT = Voltage Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
• arg2 = voltage Detailed Description The voltage sensor identified in the message is faulty, or the voltage exceeds the preset warning threshold. This condition can cause system performance issues and degradation in the moitoring capability of the system. Recommended Response Action Do one of the following to resolve the issue: 1) Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board.
LCD Message No LCD message display defined. Initial Default. TRUE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset DONTKN OW FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VLT405 Thearg1sensor has failed with a value ofarg2Volts. Message Arguments • • arg1 = sensor name arg2 = voltage Detailed Description A voltage sensor identified in the message may have failed.
63 VME Event Messages VME0001 Message Virtual Console session started. Detailed Description Virtual Console session started. Recommended Response Action No response action is required. Category Audit SubCategory VME = Virtual Media Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VME0003 Message Virtual Console session fails to start. Detailed Description Virtual Console session fails to start. Recommended Response Action Retry the Virtual Console session initiation. Category Audit SubCategory VME = Virtual Media Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined.
VME0005 Message Virtual Console session exited. Detailed Description Virtual Console session exited. Recommended Response Action No response action is required. Category Audit SubCategory VME = Virtual Media Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Virtual Console session created. Recommended Response Action No response action is required. Category Audit SubCategory VME = Virtual Media Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE FALSE VME0008 Message Virtual Media session created.
64 VRM Event Messages VRM0009 Message No Virtual Media devices are currently connected. Detailed Description No virtual media was found to disconnect. Recommended Response Action No response action is required. Category System Health SubCategory VRM = Virtual Console Severity Severity 1 (Critical) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VRM0011 Message The Virtual Media image server is not currently connected. Detailed Description The Virtual Media server is already disconnected. Recommended Response Action No response action is required.
VRM0013 Message Virtual Media services is currently attached to the USB interface.\nIt must be detached before the image server can be connected. Detailed Description Simultaneously connecting Virtual Media and USB interface is not possible. Recommended Response Action Detach the USB interface and re-try. Category System Health SubCategory VRM = Virtual Console Severity Severity 2 (Warning) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
VRM0015 Message Virtual Console is ENABLED Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory VRM = Virtual Console Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Detailed Description Success message. Recommended Response Action No response action is required. Category Configuration SubCategory VRM = Virtual Console Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default.
Category System Health SubCategory VRM = Virtual Console Severity Severity 3 (Informational) Trap/EventID FALSE LCD Message No LCD message display defined. Initial Default. FALSE Filter Visibility IPMI Alert SNMP Alert Email Alert LC Log LCD Power Off Power Cycle Reset FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE VRM0020 Message Unable to determine current Remote Image state. Detailed Description Racadm tool failed to obtain the data.