Server Administrator Installation and Management 7.3.
Version 7.3.2 Release Date: November 2013 Previous Version 7.3.1 Importance RECOMMENDED: Dell recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers and software). What’s New Server Administrator Installation and Management do not have any updates for this release.
Issue 2: Description: Windows Scripting Host (WSH) has disabled the running of VB scripts. Resolution: By default, WSH is installed during the operating system installation. WSH can be configured to prevent the execution of .VBS scripts. On the desktop, right-click My Computer, then go to Open Tools Folder Options File Types. Look for the extension VBS and verify that File Types is set to VBScript Script File.
uninstall libsmbios versions (and the dependent software) before installing Server Administrator. • The USB arbitration service of VMWare ESX 4.1 makes the USB devices invisible to the Hypervisor. So, when DUPs or the Inventory Collector runs on the MN, the partitions exposed as USB devices are not displayed, and it reaches timeout after 15 to 20 minutes. The timeout occurs in the following cases: o o When you start DSM SA Shared Service on the VMware ESX 4.
To resolve the device driver build problems: 1. Update the DKMS version to 2.0.9 or later. 2. Uninstall the kernel source on your system. 3. Reinstall the kernel source on your system. 4. Build and install the device driver that was failing to build. 5. If Server Administrator has failed to install, either install Server Administrator using the following script, ./srvadmin-install.sh [or] Install the appropriate Server Administrator RPMs.
If you click the Configure HTTPS listener link in the Prerequisite page, the page does not time out. Resolution: To resolve this issue, close and open the page. Issue 3: Description: Browser secure site warning message. (134991) When launching the Server Administrator Installation Guide from the Prerequisite checker, a Windows message is displayed indicating that the page is blocked due to enhanced security configuration.
Issue 2: Description: Dependency issue during install. (303464) During an installation, if the libstdc++.so.5 needed by srvadmin- fails, dependency error is displayed. Resolution: Install the compatibility libraries from the Linux distribution. To install a compatibility library, use the following command: rpm -ivh compat-libstdc++*.rpm Versions Affected: 7.3 and earlier Issue 3: Description: Server Administrator components get removed during OS upgrade.
Message observed is: DRAC4 probe: DRAC4 pci device not found [FAILED] Versions Affected: 7.3 and earlier Issue 6: Description: Unable to upgrade Server Instrumentation in Interactive mode when older Server Instrumentation is installed from the custom folders. (062800) (062355) The installation of Server Instrumentation will not be successful, if you have initially installed Server Instrumentation using the custom folder and then later try to upgrade it manually.
Issue 3: Description: Wrong install directory is displayed during OM installation. (71022) Broadcom or Intel SNMP agent installers are provided by Broadcom or Intel and installation of these components in the custom directory is not supported. Issue 4: Description: On Server Administrator 7.3, while running the Repair option from Add/Remove Programs or Uninstall or Change a program window, if an error occurs, use the Repair option in the MSI.
Contacting Dell Note: Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer-service issues: 1. 2. 3. 4. 5. Go to dell.com/contactdell.