Reference Guide
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
RAC0712
Message Server failed to power up due to zero power allocated.
Detailed
Description
Server failed to power up due to zero power allocated.
Recommended
Response Action
Utilize the Chassis Management Controller web interface to check available power and server
power requirements. If sufficient power is available, allocate power necessary and retry the
operation.
Category Audit
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
RAC0713
Message Server failed to power up due to fabric mismatch.
Detailed
Description
Server failed to power up due to fabric mismatched.
Recommended
Response Action
Ensure that the hardware comtibility between the IO Module (IOM) and the Mezzanine (Mezz)
card is correct. Check the M1000e Hardware Manual for correct component compatibility.
Category Audit
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
929