Reference Guide

Recommended
Response Action
Make sure that each of the 16 user names are unique.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1017
Message Successfully modified the object value and the change is in pending state.
Detailed
Description
Any staged operation requires a job and system reboot to apply the object values.
Recommended
Response Action
To apply modified value, create a configuration job and reboot the system. To create the
commit and reboot jobs, use "jobqueue" command. For more information about the "jobqueue"
command, see RACADM help.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1018
Message The specified object or syntax is invalid.
Detailed
Description
This occurs when an incorrect syntax is used or an incorrect object is specified during the
command invocation.
Recommended
Response Action
Make sure to use the correct syntax and correct object names, and retry the operation. For
information related to the corresponding group, see RACADM help or the RACADM Users
Guide.
919