Reference Guide

RAC1011
Message The OS to iDRAC pass-through cannot be enabled.
Detailed
Description
The OS to iDRAC pass-through cannot be enabled, because the NIC is in Dedicated mode.
Recommended
Response Action
Change the iDRAC NIC mode to shared mode using "racadm set idrac.nic.selection <value>",
and retry the opeation.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1012
Message Unable to change the auto-negotiation state for the current NIC selection mode.
Detailed
Description
Unable to change the auto-negotiation state for the current NIC selection mode, because the
iDRAC NIC is in dedicated mode.
Recommended
Response Action
Change the iDRAC NIC mode to shared mode using "racadm set idrac.nic.selection <value>",
and retry the operation.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1013
Message The SNMPv3 authentication protocol state cannot be set to None if the SNMPv3 privacy
protocol state is set to None.
917