Reference Guide
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1009
Message The Active Directory objects DCLookupEnable or GCLookupEnable cannot be enabled.
Detailed
Description
The Active Directory objects DCLookupEnable or GCLookupEnable cannot be enabled, because
IPv4.DNS1, IPv4.DNS2, IPv6.DNS1, or IPv6.DNS2 is not configured.
Recommended
Response Action
Configure IPv4.DNS1, IPv4.DNS2, IPv6.DNS1, or IPv6.DNS2 using racadm set command, and
retry the operation. For example, "racadm set iDRAC.IPv4.DNS1 <address>".
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1010
Message Unable to set the power cap value.
Detailed
Description
The power cap cannot be set if the object Power.Cap is disabled.
Recommended
Response Action
Enable Power Cap setting using "racadm set System.Power.Cap.Enable < 1 | Enabled >", and
retry the operation.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE