Reference Guide

Recommended
Response Action
To monitor the job status, use the "racadm jobqueue view -i <job ID>", and delete the jobs one
at a time using the "racadm jobqueue delete -i <job ID>" command.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC995
Message Unable to retrieve the hardware inventory.
Detailed
Description
The hardware inventory cannot be retrieved because of an internal error whether or not
Collect System Inventory On Restart (CSIOR) is enabled or disabled.
Recommended
Response Action
Make sure to enable Collect System Inventory On Restart (CSIOR) feature, reboot the system,
and retry the operation. If CSIOR is already enabled, reboot iDRAC using "racadm racreset"
command.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC1028
Message Unable to download the specified certificate type.
Detailed
Description
The certificate cannot be downloaded if the certificate type specified is other than "1", "2", or
"3".
Recommended
Response Action
Make sure to specify either "1", "2", or "3" for the certificate type (-t) option, and retry the