Reference Guide

Arguments
arg1 =
file name
Detailed
Description
If Lifecycle Controller is disabled, the firmware update operation cannot continue.
Recommended
Response Action
Enable Lifecycle Controller using the "racadm set
lifecyclecontroller.lcattributes.lifecyclecontrollerstate 1" command, and retry the operation.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC991
Message Unable to run the "jobqueue" command.
Detailed
Description
The "jobqueue" command cannot be run, because the existing update jobs are transitioning to
one of these states: "New", "Downloading", or "Running".
Recommended
Response Action
Wait until the existing update jobs are completed before retrying the operation. To monitor the
status of the existing jobs, use the "racadm jobqueue view" command.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC992
Message Invalid job:
arg1
.
Arguments
arg1 =
job ID
905