Reference Guide

RAC984
Message Unable to upload the Public Key Cryptography Standards version 12 (PKCS12) file.
Detailed
Description
iDRAC is unable to extract the custom signing certificate and the private key from the Public
Key Cryptography Standards version 12 (PKCS12) file.
Recommended
Response Action
Check if the specified file and passphrase are valid, and retry the operation. If the issue
persists, contact your service provider.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC985
Message Unable to configure the object.
Detailed
Description
The object "cfgServerBootOnce" cannot be configured if the object "cfgServerFirstBootDevice"
is set to F10, F11, or BIOS value.
Recommended
Response Action
Change the value of the object "cfgServerFirstBootDevice" using the "racadm config -g
cfgServerInfo -o cfgServerFirstBootDevice<value other than F10, F11, and BIOS>" command,
and retry configuring the object "cfgServerBootOnce".
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC986
Message The "vmkey" sub-command is deprecated.
902