Reference Guide
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC920
Message This interface does not support the specified option.
Detailed
Description
From firmware racadm, the inlet temperature history can be exported only to a remote file
share.
Recommended
Response Action
Create a remote file share to export the inlet temperature history. Else, use remote/local
racadm to export to the file system accessible by the racadm executable.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC921
Message The temperature history can be exported in XML or CSV format only.
Detailed
Description
The file type specified (with the t parameter) is invalid. The temperature history can be
exported in XML or CSV.
Recommended
Response Action
Change the requested export file type to either XML or CSV. To do this, change the argument
given to the t parameter. The argument given to the parameter is case-insensitive.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
875