Reference Guide
RAC0604
Message System inventory may not be up-to-date because Collect System Inventory On Restart (CSIOR)
is disabled.
Detailed
Description
The system inventory may not be up-to-date because the Collect System Inventory On Restart
(CSIOR) feature is disabled. The CSIOR feature retrieves detailed system inventory information
during system startup and stores this information on iDRAC.
Recommended
Response Action
Enable CSIOR, restart the system and retry the operation. To enable CSIOR, press F2 (System
Setup) during system startup, navigate to iDRAC Settings >Lifecycle Controller, and select the
Enabled option for Collect System Inventory on Restart.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RAC0605
Message There are no jobs to be displayed.
Detailed
Description
There are no jobs to be displayed.
Recommended
Response Action
No response action is required.
Category Configuration
SubCategory RAC = RAC Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
789