Reference Guide
Category System Health
SubCategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PWR2402
Message Power management firmware not responsive.
Detailed
Description
The iDRAC controller cannot communicate with the power management firmware. The system
may operate in a performance degraded state.
Recommended
Response Action
"1) Disconnect system input power, wait one minute, reconnect system input power. 2) Re-flash
system BIOS. 3) Upgrade system BIOS to the latest revision."
Category System Health
SubCategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PWR2403
Message Power management firmware responsive
Detailed
Description
The iDRAC controller established communication to the power management firmware. System
performance returns to normal.
Recommended
Response Action
No response action is required.
Category System Health
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
778