Reference Guide
Detailed
Description
Host failed to power up bacause CMC MPCM mode is enabled.
Recommended
Response Action
Disable MPCM mode to power up.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR2400
Message Power management firmware unable to maintain power limit
Detailed
Description
The power management firmware cannot reduce power consumption to meet configuration or
user defined settings,
Recommended
Response Action
"1) Review system power policy. 2) Check system event logs for thermal or power related
exceptions."
Category System Health
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PWR2401
Message Power management firmware initialization error
Detailed
Description
The iDRAC controller detected that the power management firmware did not initialize properly.
The system may operate in a performance degraded state.
Recommended
Response Action
"1) Disconnect system input power, wait one minute, reconnect system input power. 2) Re-flash
system BIOS. 3) Upgrade system BIOS to the latest revision."