Reference Guide
not be connected properly or diconnected. 3) The power supply unit has failed. 4) There is an
input power failure.
Recommended
Response Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2) Reconnect the
power cable to the power supply unit. 3) Install a new power supply unit 4) Restore the input
power supply.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PSU1050
Message
arg1
is switched ON.
Arguments
•
arg1 =
power supply name
Detailed
Description
The power supply identified in the message is switched ON.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory PSU = Power Supply
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PSU500
Message Unable to get the current server power status.
747