Reference Guide

Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PSU101
Message Power supply
arg1
is not present.
Arguments
arg1 =
power supply unit
Detailed
Description
The power supply unit identified in the message is not present, because of the one of the
following reasons: 1) The power supply unit is not correctly seated. 2) The power cable may not
be connected properly or diconnected. 3) The power supply unit has failed. 4) There is an input
power failure.
Recommended
Response Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2) Reconnect the
power cable to the power supply unit. 3) Install a new power supply unit 4) Restore the input
power supply.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PSU102
Message Power suppy
arg1
status is unknown.
Arguments
arg1 =
power supply unit
Detailed
Description
The status of the power supply unit identified in the message is unknown, because of one of
the following reasons: 1) The power supply unit is not correctly seated. 2) The power cable may
746