Reference Guide
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PSU0914
Message A predictive failure detected on power unit
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
Status from the power supply indicates a power supply exception occurred. The power supply
will try to operate. System Performance and power redundancy may be degraded or lost.
Recommended
Response Action
Remove input power and re-install supply at the next service window.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PSU100
Message Power supply
arg1
is offline.
Arguments
•
arg1 =
power supply unit
Detailed
Description
The power supply unit identified in the message is offline, because of the one of the following
reasons: 1) The power supply unit is not correctly seated. 2) The power cable may not be
connected properly or diconnected. 3) The power supply unit has failed. 4) There is an input
power failure.
Recommended
Response Action
Do one of the following to resolve the issue: 1) reseat the power supply unit. 2) Reconnect the
power cable to the power supply unit. 3) Install a new power supply unit 4) Restore the input
power supply.
Category System Health
SubCategory PSU = Power Supply
745