Reference Guide
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Cannot communicate with PSU <number>. Reseat PSU.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0032
Message The temperature for power supply
arg1
is in a warning range.
Arguments
•
arg1 =
number
Detailed
Description
System performance may be degraded.
Recommended
Response Action
Check the system operating environment, including airflow and inlet temperature. Check
system logs for temperature and thermal component failures.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID 2186
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0033
Message The temperature for power supply
arg1
is outside of range.
Arguments
•
arg1 =
number
Detailed
Description
System performance may be degraded.
Recommended
Response Action
Check the system operating environment, including airflow and inlet temperature. Check
system logs for temperature and thermal component failures.
728