Reference Guide

Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Power input for PSU <number> is outside of range. Check PSU cables
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0005
Message The power input for power supply
arg1
is outside of the allowable range, but it is attached to the
system.
Arguments
arg1 =
number
Detailed
Description
The operating requirements for the power supply may be found in product documentation or on
the power supply itself.
Recommended
Response Action
Verify the input power is within the operating requirements for the power supply.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID 2186
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
PSU0006
Message Power supply
arg1
is incorrectly configured.
Arguments
arg1 =
number
Detailed
Description
Power supplies should be of the same input type and power rating.
Recommended
Response Action
Install matched power supplies and review product documentation for proper configuration.
Category System Health
724