Reference Guide

Detailed
Description
The system ran out of memory while attempting to perform an operation. This has been
deprecated.
Recommended
Response Action
Retry the operation. If more than one operation was attempted retry them one at a time.
Category Configuration
SubCategory PR = Part Exchange
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PR28
Message Unable to locate device in current configuration.
Detailed
Description
The device that the job was intended for is no longer detected. This could be due to the device
being removed, disabled, or a failure.
Recommended
Response Action
If the device was removed, reinsert the device and retry the operation. If the device was
disabled, reenable the device and retry the operation.
Category Configuration
SubCategory PR = Part Exchange
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PR29
Message Unable to locate device in previous configuration.
Detailed
Description
The device that the job was intended for has no previous information recorded. The request
has failed as this information is required to initiate the operation. This has been deprecated.
Recommended
Response Action
Enable the Collect System Inventory on Restart attribute of the Lifecycle Controller and restart
the system. Alternatively, use the Unified Server Configurator utility.