Reference Guide
Arguments
•
arg1 =
physical disk name
Detailed
Description
The physical disk identified in the message is not compliant with the standards set by the
hardware provider and is not supported.
Recommended
Response Action
Replace the physical disk with a supported physical disk that is provided by an authorized
hardware provider.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR215
Message Copyback task to
arg1
has failed.
Arguments
•
arg1 =
physical disk name
Detailed
Description
The Replace Member Disk operation did not complete succesfully because of internal errors.
The error may be due to problems with the source or target physical disks or the controller may
be out of resources.
Recommended
Response Action
Retry the Replace Member Disk operation with a different target physical disk. If the problem
persists, check the condition of the target physical disk and replace if necessary, then rety the
operation.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
684