Reference Guide

Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR209
Message The power status of
arg1
is changed from
arg2
to
arg3
.
Arguments
arg1 =
physical disk name
arg2 =
previous power status
arg3 =
current power status
Detailed
Description
The Manage Physical Disk Power feature is enabled for physical drives and the power status
of the drives changed.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR210
Message Successfully updated configuration data on the
arg1
.
Arguments
arg1 =
physical disk name
Detailed
Description
This event is generated while initializing the drives during reboot. The controller updated the
configuration data on the physical disks identified in the message. The drive configuration was
updated because the following conditions were present: 1) The spundown drives were used for
configuration. Spundown drives are drives that are temporarily powered off because power
saving option is enabled. 2) The storage controller was not able to update the Configuration On
Disk (COD) records on the drive while they were spundown.
681