Reference Guide

Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR85
Message Security subsystem errors detected for
arg1
.
Arguments
arg1 =
physical disk
Detailed
Description
Errors were detected with security related operations on the disk. The data on the disk might
not be retrieved or stored successfully. In addition, the security of the stored data might be at
risk.
Recommended
Response Action
Verify the disk is a Secure Encrypted Disk and is not locked. If it is not, replace the disk with a
Secure Encrypted Disk. See the storage hardware documentation for more information.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
Trap/EventID 4345
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PDR86
Message Bad block table on
arg1
is full.
Arguments
arg1 =
physical disk
Detailed
Description
The number of blocks on the disk that exhibit an error has exceeded the capacity of the drive to
remap. Any future writes to bad sectors will be unrecoverable.
Recommended
Response Action
Replace the disk.
Category Storage
SubCategory PDR = Physical Disk
656