Reference Guide
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE FALSE TRUE FALSE FALSE FALSE FALSE
PDR7
Message
arg1
has degraded.
Arguments
•
arg1 =
physical disk
Detailed
Description
A physical disk has reported an error condition and may be degraded. The physical disk may
have reported the error condition in response to a check consistency or other operation.
Recommended
Response Action
Replace the degraded physical disk. Identify the disk that is degraded by locating the disk that
has a red "X" for its status. Perform a rescan after replacing the disk.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR70
Message Copyback started from
arg1
to
arg2
.
Arguments
•
arg1 =
physical disk
•
arg2 =
physical disk
Detailed
Description
A copyback operation began to copy data from one physical disk to another physical disk. This
may be due to a user initiated operation or a predictive failure.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
648