Reference Guide

Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR49
Message The dedicated hot spare
arg1
is too small.
Arguments
arg1 =
PD Name
Detailed
Description
The dedicated hot spare is not large enough to protect all virtual disks that reside on the disk
group.
Recommended
Response Action
Assign a larger disk as the dedicated hot spare.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PDR5
Message
arg1
is removed.
Arguments
arg1 =
PD Name
Detailed
Description
A physical disk has been removed from the disk group. This alert can also be caused by loose
or defective cables or by problems with the enclosure.
Recommended
Response Action
Do one of the following: 1) If a physical disk was removed from the disk group, either replace
the disk or restore the original disk. Identify the disk that was removed by locating the disk that
has a red "X" for its status. 2) Perform a rescan after replacing or restoring the disk. 3) If a disk
was not removed from the disk group, then check for cable problems. Refer to product
documentation for more information on checking the cables. 4) Make sure that the enclosure is
powered on. 5) If the problem persists, check the enclosure documentation for further
diagnostic information.
636