Reference Guide
Recommended
Response Action
Although this alert is provided for informational purposes, you may need to assign a new hot
spare to the virtual disk. See Protecting Your Virtual Disk with a Hot Spare for more
information.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR19
Message SMART FPT exceeded for
arg1
.
Arguments
•
arg1 =
PD Name
Detailed
Description
A disk on the specified controller has received a SMART alert (predictive failure) indicating
that the disk is likely to fail in the near future.
Recommended
Response Action
Replace the disk that has received the SMART alert. If the physical disk is a member of a non-
redundant virtual disk, then back up the data before replacing the disk. Removing a physical
disk that is included in a non-redundant virtual disk causes the virtual disk to fail and may
cause data loss.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR2
Message Insufficient space available on
arg1
to perform a copyback operation.
Arguments
•
arg1 =
physical disk
619