Reference Guide
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR15
Message
arg1
rebuild is complete.
Arguments
•
arg1 =
physical disk
Detailed
Description
This message is generated after a rebuild completes on a physical disk.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR16
Message Predictive failure reported for
arg1
.
Arguments
•
arg1 =
physical disk
Detailed
Description
The physical disk is predicted to fail. Many physical disks contain Self Monitoring Analysis and
Reporting Technology (SMART). When enabled, SMART monitors the disk health based on
indications such as the number of write operations that were performed on the disk.
Recommended
Response Action
Replace the physical disk. Even though the disk may not have failed yet, it is strongly
recommended that the disk be replaced. Review other messages for additional information.
Category Storage
SubCategory PDR = Physical Disk
617