Reference Guide

32
PDR Event Messages
PDR1
Message
arg1
copyback stopped for rebuild.
Arguments
arg1 =
physical disk
Detailed
Description
This message is generated after a copyback stops on a physical disk during a rebuild
operation.
Recommended
Response Action
Wait for rebuild to finish, then copyback should resume.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PDR10
Message
arg1
rebuild has started.
Arguments
arg1 =
physical disk
Detailed
Description
This message is generated after a rebuild starts on a physical disk.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID FALSE
613